3.11 Pulse Rate

0240

0340

0440

0640

1000

1540

Option

This applies to the Relay Pulsed Output option only. Units with this option provide pulses to indicate power consumption (kWh).

This screen allows setting of the kWh pulse rate divisor. On a two part DIS 1540/Integra 1560, this screen will set the pulse rate for the kvarh pulse relay (where fitted) also. By default, the unit produces one pulse per kWh. Changing this divisor changes the output pulse rate, as follows:

Divisor

One pulse per:

1

1 kWh

10

10 kWh

100

100 kWh

1000

1000 kWh (DIS1540 with 1560/1580 only)

Press >> to accept the currently displayed value. The next

Set-up screen will then appear.

To change the pulse rate divisor, press .

Use the key to scroll the value through the available values 1, 10, 100, 1,000. If the maximum power is greater than 3.6 megawatts, the range of divisors will be restricted to force an upper limit to the number of pulses/hour of 3600.

Select the required divisor and press >> to confirm your selection. The Confirmation screen will appear.

Edit

To change the value again, press . The Edit screen will

 

reappear.

To accept the displayed value, press >>. The next Set-up screen will appear.

Confirmation

30 Integra 1540, 1000, 0640, 0440, 0340, 0240 Issue 1 04/03

Image 32
Contents Energy Division Crompton Switchboard Integra Contents Setting up Specification Maintenance Appendix a CE Declaration of Conformity Basis of measurement and calculations Serial CommunicationsIntroduction THDUnit Characteristics 3 0440Integra 1540, 1000, 0640, 0440, 0340, 0240 Issue 1 04/03 Default display Demand Calculation Maximum PowerSecondary Voltage Analogue Output Option RS485 Serial OptionPulse Output Option Start Up Screens Display ScreensLayout System Screen Line to Neutral Voltage %THD System %THD ScreenLine to Neutral Voltages Line Currents Line to Line VoltagesLine to Line Voltages %THD Line Currents %THD Neutral Current, Frequency and Power FactorPower Active Energy kWh Reactive Energy kVArhOver Range DemandMaximum Demand KWh and kVArh Display Range Setting upError Messages Number Entry Procedure Integra 1540, 1000, 0640, 0440, 0340, 0240 Issue 1 04/03 Access with Password Protection AccessAccess with No Password Protection Integra 1540, 1000, 0640, 0440, 0340, 0240 Issue 1 04/03 Changing the Password Full Scale Current Potential Transformer Primary VoltageIntegra 1540, 1000, 0640, 0440, 0340, 0240 Issue 1 04/03 Potential Transformer Secondary Value Demand Integration Time Resets Pulsed Output, Pulse Duration Pulse Rate 12 RS485 Baud Rate 13 RS485 Parity Selection 14 RS485 Modbus Address Analogue Output Set Up Second ChannelReverse Operation Reduced output rangeAnalogue Output Scaling Example Reading A1r or A2rReading Top A1rt or A2rt Reading Bottom A1rb or A2rbSummary Power FactorOutput Bottom A1ob or A2ob USA Reading European Convention North American Convention Output Phase Angle L1-L2 Calculated Parameter Number Wire Reading Parameter Selection A1r or A2rReading Top A1rt or A2rt Reading Bottom A1rb or A2rb Specification Display Only VersionsDisplay/Transducer Combined 0240, 0340, 0440 121 240V L-L 70.1 139V L-N Reference conditions of influence quantities Measuring RangesAccuracy Display/Tranducer Combined 1000 Auxiliary Power Supply Reference conditions Nominal range of use of influence quantities for measurands Functional rangesScreen StandardsSerial Communications Option Modbus RS485Active Energy Pulsed Output Option Integra 1540 OnlyBasis of measurement and calculations Reactive and Apparent PowerEnergy resolution Total Harmonic Distortion 1540 only Modbus Implementation Serial CommunicationsRS485 Port Modbus or JC N2 Input Registers Parameter Modbus Start Modbus Holding Registers and Integra set up High Low ByteMetasys release requirements RS485 Implementation of Johnson Controls MetasysApplication details Design considerations Support for Metasys IntegrationSupport for Crompton Integra operation Metasys N2 application Integra 1560/1580 Point Mapping tableMaintenance Integra 1540, 1000, 0640, 0440, 0340, 0240 Issue 1 04/03 Integra 1540, 1000, 0640, 0440, 0340, 0240 Issue 1 04/03 Integra 1540, 1000, 0640, 0440, 0340, 0240 Issue 1 04/03

1540 specifications

The Tyco 1540 is an innovative and versatile telecommunications solution that has gained popularity in various industries due to its robust features and state-of-the-art technology. Designed primarily for high-performance communication, the Tyco 1540 has become a go-to choice for service providers, enterprises, and data centers looking to enhance their network capabilities.

One of the main features of the Tyco 1540 is its advanced multiplexing technology. This allows for the efficient transmission of multiple data signals over a single optical fiber, maximizing bandwidth utilization and reducing infrastructure costs. The device supports a range of protocols, making it adaptable to various network environments and requirements.

The Tyco 1540 also incorporates automation capabilities, which significantly streamline network management and operational processes. With built-in monitoring and diagnostic tools, administrators can easily track performance metrics, troubleshoot issues, and optimize network resources in real-time, thus ensuring seamless communication and minimal downtime.

Another standout characteristic of the Tyco 1540 is its scalability. As businesses grow and their communication needs evolve, the Tyco 1540 can be adjusted to accommodate increased data traffic without needing extensive hardware upgrades. This scalability is essential for organizations that need to remain agile and responsive in an ever-changing technological landscape.

Security is a critical concern in telecommunications, and the Tyco 1540 addresses this with robust encryption protocols. This functionality safeguards sensitive data transmitted across the network, providing peace of mind for organizations handling confidential information. Moreover, the device is designed to comply with industry standards and regulations, ensuring that users meet necessary compliance requirements.

Energy efficiency is another notable aspect of the Tyco 1540. The device is engineered to consume less power, reducing operational costs and minimizing the environmental impact. The incorporation of energy-saving technologies reflects a commitment to sustainable practices, which is increasingly important in today's eco-conscious world.

In conclusion, the Tyco 1540 represents a significant advancement in telecommunications technology. Its features, including advanced multiplexing, automation capabilities, scalability, enhanced security, and energy efficiency, make it an ideal choice for a wide range of applications. Organizations looking to improve their communication infrastructure can certainly benefit from integrating the Tyco 1540 into their systems. With its robust performance and adaptability, the Tyco 1540 stands out as a leading solution in the evolving telecommunications landscape.