Perle Systems TS2, DS1 manual RJ45F to DB25F DTE Crossover Adapter

Page 228

Starter Kit (Adapters/Cable)

RJ45F to DB25F DTE Crossover Adapter

The following diagram shows the IOLAN RJ45JDB25F DTE crossover adapter pinouts. This is model number DBA0010.

RJ45F

 

 

 

DB25F

 

 

 

 

 

 

(TxD) 4

 

3

(RxD)

 

(RxD) 5

 

2

(TxD)

 

(GND) 6

 

7

(GND)

 

(DTR) 8

 

6

(DSR)

 

 

 

8

(DCD)

(DSR) 3

 

 

20 (DTR)

 

(RTS) 2

 

5

(CTS)

 

(CTS) 7

 

4

(RTS)

 

Accessories 228

Image 228
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Preface About This BookIntended Audience DocumentationTypeface Conventions Online HelpTable of Contents Configuration Methods Getting Started Using DeviceManager and WebManager Serial Port Profiles Network Settings Configuring Users Configuring Security UDP Configuring the System Controlling the I/O Channels Appendix a Virtual Modem AT Commands Appendix D I/O Wiring Diagrams Appendix H Data Logging Appendix I Modbus Remapping 241 Introduction About the IolanIolan Family Models Iolan Features HardwareSoftware Security Connectivity IntroductionIolan Components Power Supply Specifications Getting to Know Your IolanDesktop Models OverviewDS1 Serial ActivityTop View End ViewConsole/Serial Switch Console ModeSerial Mode Powering Up the Iolan Models with Barrel ConnectorModels with Terminal Block Connector Configuration Methods Chapter Configuration Methods Overview Configures an IP AddressRequires a Configured IP Address Easy Config Wizard Access Platforms FeaturesConnecting to the Iolan Using DeviceManager DeviceManagerDeviceManager Using DeviceManager Navigating the OptionsConnecting to the Iolan Using WebManager Downloading the ConfigurationWebManager WebManager Using WebManager Command Line Interface Connecting to the Iolan Using the CLIThrough the Network Using the CLI Connecting to the Iolan Using the MenuMenu Through the Serial PortUsing the Menu Connecting to the Iolan Using DHCP/BOOTP Using DHCP/BOOTPDHCP/BOOTP Parameters Connecting to the Iolan Using Snmp SnmpUsing the Snmp MIB Easy Configuration Wizard Getting StartedSetting Up the Network Using a Direct Serial Connection to Specify an IP Address Using a Direct Serial Connection to Enable BOOTP/DHCP Using ARP-Ping For an IPv6 NetworkSetting Up the Serial Ports Setting Up the Serial Ports Setting Up Users Using DeviceManager WebManager Navigating DeviceManager/WebManager DeviceManagerWebManager Using DeviceManager to Connect to the Iolan Starting a New SessionAssigning a Temporary IP Address to a New Iolan Adding/Deleting IOLANs Manually Logging in to the IolanUsing WebManager to Connect to the Iolan Configuration FilesCreating a New Iolan Configuration in DeviceManager Logging into the IolanOpening an Existing Configuration File Importing an Existing Configuration FileManaging the Iolan Serial Ports FunctionalityEditing a Serial Port Resetting a Serial Port Serial Port Profiles Common TabsOverview Hardware Tab Field DescriptionsDefault None Default FullDefault Auto Enable InboundPacket Forwarding Tab Field Descriptions Enable Trigger1 Enable Trigger2Packet Definition Packet SizeConsole Management Profile FunctionalityDefault Telnet General Tab Field DescriptionsProtocol Listen for Connections on TCP Port IP AddressAdvanced Tab Field Descriptions Default 10 ms Dial Dial OutDial Timeout TruePort ProfileDial Retry ModemSystem Default Enabled Host Name Connect Default Disabled Define AdditionalConnect to remote TCP PortAdding/Editing Additional TruePort Hosts Backup Host Adding/Editing a Multihost EntryPrimary Host Signals high Day Motd Default Disabled Enable TCPWhen Enable Data Logging Trueport Lite Mode Dial Retry Connection Workstation/Server on the network Default Enabled TCP Sockets ProfileDefault Disabled Adding/Editing Additional Hosts Adding/Editing a Multihost Entry Day Motd Default Disabled Enable Data LostDefault 10 ms Dial UDP Sockets Profile Serial Port Profiles UDP Entry Connections on UDP port DirectionStart IP Address End IP AddressPort UDP port to use Default 0 zero Default 10 msTerminal Profile Session StringsDefault Dumb VT100TVI925 VT320 specifically supporting VT320-7Default Disabled Protocol When any data isAutomatically ReceivedDefault Disabled Hotkey Prefix Session TimeoutData Range User Service Settings Login SettingsTelnet Settings InterruptQuit EraseSerial Tunneling Profile Client Default Disabled Host Name Act As TunnelServer Delay After Break Break LengthVirtual Modem Profile 100 DTR Signal Acts as RTS Signal Always On DCDRTS Signal Acts as AT CommandResponse Delay Phone Number to Host Mapping VModem Phone Number EntryControl Signal I/O Profile Phone NumberHost IP Address Input Signal Field Descriptions Invert SignalAuto Clear Mode DescriptionOutput Signal Field Descriptions Mode Default Disabled SyslogManual Clear Failsafe ActionModbus Gateway Profile IP address Advanced Slave Settings Button Destination SlaveIP Mappings ButtonDefault 30 ms Message TimeoutDefault 1000 ms Advanced Field DescriptionsModbus Slave IP Settings Field Descriptions Adding/Editing Modbus Slave IP SettingsUID Start Default Host Default TCPUID End TypeModbus Slave Advanced Settings Field Descriptions Default Off Custom Application ProfileGeneral Tab Field Description Advanced Serial Settings Tab Closing Serial Port Default Disabled Deny MultipleAdvanced Field DescriptionsModems Tab Adding/Editing a ModemName Name of the modem TruePort Baud Rate Tab Field DefinitionsNetwork Settings IP Settings IPv4 SettingsSystem Name DomainIPv6 Settings Adding/Editing a Custom IPv6 Address Default IPV6 68-1500 bytes AdvancedHost Table Adding/Editing a HostAdd Button Adds a host to the host table Edit Button Delete Button Deletes a host from the host tableRoute List Adding/Editing RoutesDefault Default IPv4 Subnet MaskIPv6 Prefix Bits HostConfiguring Users User Settings Adding/Editing Users General TabDefault Normal LevelServices Tab ServiceDefault DSPrompt Host IPDefault English Advanced TabLanguage Sessions Tab Session 1, 2, 3 ConnectSerial Port Access Tab Configuring Security ServicesField Descriptions Configuring I/O Interfaces Technical SpecificationsSettings Access FunctionalityAdvanced Slave Modbus Settings Failsafe Timer Functionality UDP Functionality Temperature Functionality UDP SettingsDefault Celsius UDP EntryChannels AnalogMonitoring Application A4D2 Analog I/O AnalogDefault Current Alarm SettingsMonitoring Application Digital I/OInput Mode 147 Output Mode Default SinkDefault Manual Pulse ModeInactive Signal Active SignalMonitoring Application A4D2Relay Relay I/O151 Digital I/O Extension Front DoorWarehouse Perle Iolan Reception Remote HostCurrent Alarm State 1 Byte z 0 = Not in alarm Message type 1 ByteInput number 1 Byte Enable I/O ExtensionInput TCP Port Hosts Local connectionSimultaneously Communicate to the Primary Host Temperature Temperature I/O Industrial FreezersDefault RTD Alarm Settings Basic Analog Alarm SettingsAdvanced Analog Alarm Settings Clear ModeTrigger Type ClearUDP Unicast Format UDP Broadcast PacketLength Enabled Analog SectionSection Channel Serial Pin Signal Section Digital/Relay SectionLength Channel Length PinModbus Slave UDP Unicast ExampleModbus Serial Application Connected to the Serial Port Modbus Serial Application Connected to the NetworkModbus I/O Access Modbus TCP ApplicationFunction Codes Coil/Register Descriptions Serial Port Coil/Register Descriptions A4/T4 RegistersData Model A1/T1 A2/T2 A3/T3 A4/T4 Holding Registers Input RegistersA4D2/A4R2 Registers Data Model D1/R1 D2/R2 CoilsSerial Pin Signals D4/D2R2 RegistersData Model D3/R1 D4/R2 Coils Data Model Pin CoilsModbus Serial Application TruePort Power Digital Output TruePort I/OTruePort/Modbus Combination PC running aAPI Over TruePort Only PC running Custom Application API TruePortAccessing I/O Data Via TruePort SetupIntroduction Format of API Commands Get CommandsCommand Format Response FormatSet Commands Successful Response Format Unsuccessful Response FormatExample 1 Turn on the first relay on a D2R2 unit Example 2 Turn on the first and second relay on a D2R2 unitError Codes Snmp TrapsConfiguring the System Chapter AlertsSyslog Management Snmp Traps Tab Field Descriptions Default 1 second Custom App/PluginField Description Login Tab Field Descriptions Bootup Files Tab Field Descriptions WebManager WebManager. Default Disabled Message of the Day Motd Tab Field DescriptionsTftp Host FilenameDefault 3 seconds Tftp Tab Field DescriptionsRetry Controlling the I/O Channels Activate Output Manually activates the channel output System Administration Chapter Managing Configuration FilesSaving Configuration Files Downloading Configuration Files Downloading Configuration Files to Multiple IOLANs Reboot ServerServer Name Uploading Configuration Files Specifying a Custom Factory Default ConfigurationResetting the Iolan to the Default Configuration Downloading Iolan FirmwareCalibrating I/O Calibrating Analog InputCalibrating Voltage Calibrating CurrentCalibrating Temperature Input Calibrating ThermocoupleCalibrating RTD Resetting Calibration Data Calibrating Analog ChannelsSetting the IOLAN’s Date and Time Rebooting the IolanResetting the Iolan to Factory Defaults Language Support Loading a Supplied LanguageSoftware Upgrades and Language Files Translation GuidanceDownloading Terminal Definitions Creating Terminal Definition FilesResetting Configuration Parameters For exampleLost admin Password Commands Virtual Modem Initialization CommandsAT&Sn AT&RnAT&Cn Pinouts and Cabling Diagrams Serial PinoutsDB25 Male DB25 Female RJ45 DB9 Male Serial Only DB9 Male I/OEIA-232 Cabling Diagrams Terminal DB25 ConnectorDB25 Male DB25 FemaleRJ45 DB9 Male10-pin Pin Modem DB25 Connector Iolan RJ45 DCERxD TxD DTR 20 DTR GND Setting Jumpers Port IolanIolan DB25 Male/Female Iolan RJ45 DIP Digital I/O Module Analog Input Module Wiring I/O Diagrams Digital Input Wet ContactDigital Input Dry Contact Digital Output Sink Digital Output SourceTemperature Input Analog InputCurrent VoltageRTD 2-Wire RTD 3-WireRTD 4-Wire Relay OutputNormally Closed Contact TruePort Utility TruePortAPI I/O Access Over TruePort API Request FormatAPI Response Format Error Codes Accessories Starter Kit Adapters/CableRJ45F to DB25M DTE Crossover Adapter RJ45F to DB25M DCE Modem Adapter RJ45F to DB25F DTE Crossover Adapter RJ45F to DB9M DTE Crossover Adapter Sun/Cisco RJ45M Connector Cable for Rack Mount Models RJ45F to DB9F DTE Crossover AdapterStarter Kit Adapters/Cable Accessories Troubleshooting Hardware ProblemsCommunication Issues Power/Ready LED continues to blink green in desktop modelsDeviceManager Problems Host ProblemsLogin Problems Login Problems Problems with Terminals Unknown IP AddressDHCP/BOOTP Problems Language ProblemsLong Reboot Cycle ModelsIPv6 Issues Contacting Technical Support Making a Technical Support QueryRepair Procedure Feedback on this ManualData Logging Trueport ProfileTCP Socket Profile Modbus Remapping Feature Configuring the Modbus UID Translation FeatureCreate a configuration file Line format for one UID isConfiguring the Modbus UID Translation Feature Glossary RIP Routing Information ProtocolRoaming Callback Silent ConnectionBootp IndexSnmp
Related manuals
Manual 224 pages 30.96 Kb Manual 88 pages 61.31 Kb Manual 122 pages 55.83 Kb

DS1, TS2 specifications

Perle Systems TS2 and DS1 are advanced serial-to-Ethernet devices designed to facilitate seamless integration of serial devices with modern IP networks. These devices serve as crucial tools for businesses looking to enhance their communication capabilities while leveraging existing infrastructure.

One of the standout features of the Perle TS2 and DS1 is their ability to support multiple serial protocols including RS232, RS422, and RS485. This versatile support allows businesses to connect various legacy devices to their networks, ensuring that critical equipment can still communicate effectively in an increasingly digital landscape.

The TS2 model is particularly noted for its dual serial ports, enabling simultaneous communication with multiple devices. This capability is invaluable for applications requiring real-time data transmission, such as remote monitoring and automated control systems. The DS1 model, on the other hand, is designed for single-port use, making it an ideal solution for smaller-scale operations or specific single-device connections.

Both the TS2 and DS1 incorporate advanced features such as configuration through a web interface, which simplifies setup and management. Users can easily access device settings and monitor performance metrics remotely, enhancing operational efficiency. These devices also support various network protocols such as TCP/IP, UDP, and ICMP, ensuring compatibility with a wide range of network architectures.

In terms of security, Perle Systems prioritize user data protection. The TS2 and DS1 offer features including SSL encryption and SSH protection, providing an added layer of security for sensitive information transmitted over the network. This is particularly important for industries where data integrity and security are paramount, such as healthcare and finance.

Additionally, the rugged design of both devices ensures reliable performance even in harsh environments. With extended temperature ratings and robust housing, the TS2 and DS1 can operate in diverse conditions without compromising functionality.

To summarize, the Perle Systems TS2 and DS1 provide a reliable and flexible solution for connecting legacy serial devices to modern networks. With their support for multiple serial protocols, web-based management, robust security features, and rugged design, these devices cater to a variety of industries looking to modernize their communication infrastructure while maintaining existing equipment. Whether for large-scale operations or smaller implementations, the TS2 and DS1 equip businesses with the tools needed for effective serial communication in an IP-driven world.