QSC Audio S series user manual Tx Error

Page 21

Operation: Network Activity (Status) Indicators

Tx

This LED illuminates green for at least 50 milliseconds while the unit is transmitting Ethernet data. This indicator will blink when transmit activity is present. The activity of this indicator is dependent on the RAVE model and bundle type. This is a physical layer indicator and does not guarantee that data is being transmitted properly from the CobraNet core.

Tx Error

This LED illuminates red for at least 1 second if a unit is having trouble transmitting CobraNet related data. Failure here may be due to network inaccessibility, duplicate transmit bundle assignments, improper network configuration or an inter- nal fault. This indicator will also illuminate with the RxError LED if the device cannot synchronize to the network clock.

Conductor

This yellow LED will illuminate whenever the unit is acting as the system “conductor”. In this mode, the unit provides the system synchronization and accessibility resources. Arbitration for the conductor role is initiated during system initializa- tion or when a unit with a higher priority than the current conductor is added to the network. Conductor priority is based on the transmission capabilities of the device. The device with the least amount of transmission requirements is the best candidate for the conductor role. Currently, the hierarchy is as follows:

1.

RAVE 160s-24 and 80s

highest

2.

RAVE 188s-24 and 88s

mid position

3.

RAVE 161s-24 and 81s

lowest

In the event there are two or more units with the highest priority arbitrating for the conductor role, the MAC address will be used as the deciding factor.

Note that there should be one, and only one, conductor per LAN or VLAN. Multiple conductor indicators may point to an unintentional partition in the network architecture because of multicast filtering.

Fault

This red LED illuminates whenever the unit detects an unexpected internal fault. If the RAVE unit cannot pass its self- induced self-test (POST), the fault indicator will usually repeat a sequence of flashes, which indicates where the POST failure occurred. If the RAVE does pass the self-test but cannot perform or continue its operation, a blink code consisting of three flash patterns may be repeated on the fault indicator. Additionally, the RAVEs audio metering LEDs may display a binary fault code. Fault codes are provided by Peak Audio for each major release of CobraNet code. When communicated by the user, these front panel fault code displays may help QSC’s Technical Services department in providing a quick remedy for a faulty RAVE unit.

21

Image 21
Contents Rave Explanation of Graphical Symbols Explication DES Symboles GraphiquesErklärung DER Graphischen Symbole Table of Contents Introduction Overview Introduction Illustration of Rave units Introduction Glossary Introduction Glossary Introduction How It Works Outs Introduction How It WorksChannel Routing Introduction Channel RoutingRequired tools #2 Phillips screwdriver Input Level Sensitivity Rave 161s-24 and 188s-24 only Connections 100BASE-TX Ethernet Installation Rack MountingRack Mounting ALL Models Ethernet Connection ALL ModelsAnalog Audio Connections Connections Analog Audio Inputs/Outputs Rave 160/161/188Digital Audio Connections Connections Digital Audio Inputs/Outputs Rave 80/81/88AC Power FusesSLAVE/SYNC Input RS-232 Port Redundant Configuration Synchronizing to AES/EBU Synchronizing to AES/EBU Status Indicators Operation Network Activity Status IndicatorsTx Error Operation Audio Signal Level Indicators Audio Signal Level IndicatorsAudio Metering Error Reporting Bundle AssignmentBundle Activity Operation Program/Software Kill, Routing Program and Software KillRouting Operation Routing Switched Networks Network Design Considerations Switched Networks Repeater Networks Network Design Considerations Repeater NetworksGeneral SpecificationsRear Panel Connections Audio Buffering Appendix Ethernet CablingRS-232 Port Information Network Hardware Manufacturers CAT-5 UTP Manufacturers Appendix ResourcesProduct Warranty How to Contact QSC Audio Products