VisuaLink 128/384 Engineering Guide

Error Response Table

 

 

4: Error Response Table

If a command input from console is not understandable or has a different configuration, an error response is transmitted to the console. Error responses are shown in the following table.

Table 4-1: Error Response Table (1/2)

ERR Number

Contents

Countermeasures

 

 

 

ERR01

Syntax error.

Check the format of a command

 

 

 

ERR05

It is a command that cannot be

Check current system settings

 

accepted by the current system.

 

 

 

 

ERR06

It is during an initial setting.

Try again

 

 

 

ERR07

Time out

Try again

 

 

 

ERR09

It is a command that cannot be

Check current system settings

 

executed in the current mode.

 

 

 

 

ERR10

A camera is not connected.

Check current system settings

 

 

 

ERR11

This is not a preset camera.

Check current system settings

 

 

 

ERR12

The displayed screen is not a received

Check current system settings

 

video, so a remote camera control

 

 

cannot be performed.

 

 

 

 

ERR16

NEC specific features cannot be

Check current system settings

 

performed.

 

 

 

 

ERR17

The remote terminal has no capability

It is impossible in the current configuration

 

to perform this command.

 

 

 

 

ERR18

Cannot be controlled for it is set for a

VL is in remote maintenance.

 

pass-through mode.

 

 

 

 

ERR20

MLP port has not yet been established.

Check communication status and execute

 

 

command again.

 

 

 

ERR21

Error in data speed setting combination.

Check current system settings

 

 

 

ERR22

The local site is not participating in the

Check communication status

 

conference room.

 

 

 

 

ERR23

A specified conference room is not

Check communication status and execute

 

participating in a multi-point

command.

 

conference.

 

 

 

 

ERR24

Multi-point command is either invalid or

Check communication status and execute

 

overlapping.

command.

 

 

 

ERR26

VL is not in multi-point conference.

Check communication status and execute

 

 

command.

 

 

 

ERR32

It cannot be set in the current network.

Check communication status and execute

 

 

command.

 

 

 

ERR37

The remote terminal cannot be

Check communication status and execute

 

recognized as a NEC model.

command.

 

 

 

ERR38

Local loopback cannot be done since it

Execute a command after release of the

 

is processing a remote loopback.

remote loopback.

 

 

 

ERR 40

It is in a telephone communication

Command to execute is impossible.

 

mode.

 

 

 

 

ERR41

Network in use is not an ISDN line.

Check current system settings

 

 

 

ERR42

No incoming call

Check communication status and execute

 

 

command.

 

 

 

ERR43

Currently originating a call.

Check communication status and execute

 

 

command.

 

 

 

ERR44

Incoming call

Check communication status and execute

 

 

command.

 

 

 

ERR45

On line.

Check communication status and execute

 

 

command again.

 

 

 

NDA-24233 Issue 2

Page 4-1

Page 111
Image 111
NEC NDA-24233 manual Error Response Table, Error Response /2