VisuaLink 128/384 Engineering Guide | Error Response Table |
|
|
4: Error Response Table
If a command input from console is not understandable or has a different configuration, an error response is transmitted to the console. Error responses are shown in the following table.
Table 4-1: Error Response Table (1/2)
ERR Number | Contents | Countermeasures |
|
|
|
ERR01 | Syntax error. | Check the format of a command |
|
|
|
ERR05 | It is a command that cannot be | Check current system settings |
| accepted by the current system. |
|
|
|
|
ERR06 | It is during an initial setting. | Try again |
|
|
|
ERR07 | Time out | Try again |
|
|
|
ERR09 | It is a command that cannot be | Check current system settings |
| executed in the current mode. |
|
|
|
|
ERR10 | A camera is not connected. | Check current system settings |
|
|
|
ERR11 | This is not a preset camera. | Check current system settings |
|
|
|
ERR12 | The displayed screen is not a received | Check current system settings |
| video, so a remote camera control |
|
| cannot be performed. |
|
|
|
|
ERR16 | NEC specific features cannot be | Check current system settings |
| performed. |
|
|
|
|
ERR17 | The remote terminal has no capability | It is impossible in the current configuration |
| to perform this command. |
|
|
|
|
ERR18 | Cannot be controlled for it is set for a | VL is in remote maintenance. |
|
| |
|
|
|
ERR20 | MLP port has not yet been established. | Check communication status and execute |
|
| command again. |
|
|
|
ERR21 | Error in data speed setting combination. | Check current system settings |
|
|
|
ERR22 | The local site is not participating in the | Check communication status |
| conference room. |
|
|
|
|
ERR23 | A specified conference room is not | Check communication status and execute |
| participating in a | command. |
| conference. |
|
|
|
|
ERR24 | Check communication status and execute | |
| overlapping. | command. |
|
|
|
ERR26 | VL is not in | Check communication status and execute |
|
| command. |
|
|
|
ERR32 | It cannot be set in the current network. | Check communication status and execute |
|
| command. |
|
|
|
ERR37 | The remote terminal cannot be | Check communication status and execute |
| recognized as a NEC model. | command. |
|
|
|
ERR38 | Local loopback cannot be done since it | Execute a command after release of the |
| is processing a remote loopback. | remote loopback. |
|
|
|
ERR 40 | It is in a telephone communication | Command to execute is impossible. |
| mode. |
|
|
|
|
ERR41 | Network in use is not an ISDN line. | Check current system settings |
|
|
|
ERR42 | No incoming call | Check communication status and execute |
|
| command. |
|
|
|
ERR43 | Currently originating a call. | Check communication status and execute |
|
| command. |
|
|
|
ERR44 | Incoming call | Check communication status and execute |
|
| command. |
|
|
|
ERR45 | On line. | Check communication status and execute |
|
| command again. |
|
|
|
Page |