VisuaLink 128/384 Engineering GuideConsole Command List
3.2 AUDIO Command |
|
|
|
| |
SAMD | Setting Audio Mode |
|
| ||
|
| ||||
Description: | Sets the audio coding format. The VisuaLink is capable of | ||||
|
| SBADPCM and | |||
Command Format: | SAMD p1 |
|
|
| |
|
| p1: | OFF | : | OFF |
|
|
| ULW : | G711 | |
|
|
| SBA | : | G722 |
|
|
| LDC | : | G728 |
Response: | Normal Response: OK |
| |||
|
| Error Response: | ERR01 | ||
|
|
| ERR07 | ||
|
|
| ERR14 | ||
|
|
| ERR21 | ||
|
|
| ERR87 |
RAMD | Checking Audio Mode Setting | |||
|
| |||
Description: | Check current audio mode setting | |||
Command Format: | RAMD |
|
| |
Response: | Normal Response: | p1 OK |
| |
|
|
| p1: OFF | : OFF |
|
|
| ULW : G711 | |
|
|
| SBA | : G722 |
|
|
| LDC | : G728 |
|
| Error Response: | ERR01 |
|
|
|
| ERR07 |
|
|
|
| ERR87 |
|