VisuaLink 128/384 Engineering GuideConsole Command List

3.2 AUDIO Command

 

 

 

 

SAMD

Setting Audio Mode

 

 

2-1

 

 

Description:

Sets the audio coding format. The VisuaLink is capable of μ-Law PCM,

 

 

SBADPCM and LP-CELP.

Command Format:

SAMD p1

 

 

 

 

 

p1:

OFF

:

OFF

 

 

 

ULW :

G711 (μ-Law PCM) (56 kbps)

 

 

 

SBA

:

G722 (SB-ADPCM) (48 kbps, 56 kbps)

 

 

 

LDC

:

G728 (LD-CELP) (16 kbps)

Response:

Normal Response: OK

 

 

 

Error Response:

ERR01

 

 

 

ERR07

 

 

 

ERR14

 

 

 

ERR21

 

 

 

ERR87

RAMD

Checking Audio Mode Setting

2-2

 

 

Description:

Check current audio mode setting

Command Format:

RAMD

 

 

Response:

Normal Response:

p1 OK

 

 

 

 

p1: OFF

: OFF

 

 

 

ULW : G711 (μ-Law PCM) (56 kbps)

 

 

 

SBA

: G722 (SB-ADPCM) (48 kbps, 56 kbps)

 

 

 

LDC

: G728 (LD-CELP) (16 kbps)

 

 

Error Response:

ERR01

 

 

 

 

ERR07

 

 

 

 

ERR87

 

NDA-24233 Issue 2