VisuaLink 128/384 Engineering Guide

 

 

 

 

Console Command List

 

 

 

 

 

 

 

SPIP

Setting Picture-in-Picture

 

 

 

1-3

 

 

 

 

 

 

 

Description:

Sets PIP (small screen) display

 

 

 

 

Command Format:

SPIP p1 p2

 

 

 

 

 

 

 

 

p1:

ON

:

PIP output ON

 

 

 

OFF

:

PIP output OFF

 

 

P2:

RT

: Display at top right

 

 

 

RB

: Display at bottom right

 

 

 

LT

: Display at top left

 

 

 

LB

: Display at bottom left

 

 

Note: p2 is omitted when p1 = Off

 

 

 

Response:

Normal Response:

OK

 

 

 

 

 

Error Response:

ERR01

 

 

 

 

 

 

 

ERR07

 

 

 

 

 

 

 

ERR85

 

 

 

 

 

 

 

ERR87

 

 

 

RPIP

Checking Picture-in-Picture Setting

 

1-4

 

 

 

 

 

 

Description:

Checks the current PIP display status

 

 

 

Command Format:

RPIP

 

 

 

 

 

 

 

Response:

Normal Response: p1 p2 OK

 

 

 

 

 

 

 

p1:

ON

:

PIP output ON

 

 

 

 

 

OFF

:

PIP output OFF

 

 

 

 

p2:

RT

:

Display at top right

 

 

 

 

 

RB

:

Display at bottom right

 

 

 

 

 

LT

:

Display at top left

 

 

 

 

 

LB

:

Display at bottom left

 

 

Error Response:

ERR01

 

 

 

 

 

 

 

ERR01

 

 

 

 

 

 

 

ERR87

 

 

 

NDA-24233 Issue 2