VisuaLink 128/384 Engineering Guide | Console Command List |
|
|
3.24 Communication Status Report Command
H221 | H.221 Synchronous Status Report |
|
|
|
|
Description: | H.221 reporting status change. |
Command Format: H221 p1
p1: AI : synchronization established
DI : out of synchronization
IMAC | Manufacturer Code Report |
|
|
|
|
Description: | Reports a manufacturer code for the remote site. |
| |||||||||||
Command Format: | IMAC p1 p2 p3 p4 p5 OK |
|
|
| |||||||||
|
| p1: | : Manufacturer code | 49 | : | NEC | |||||||
|
|
|
|
|
|
|
|
|
|
| Else | : | other vendor |
|
| p2: | : Division code | 00 | : | NEC | |||||||
|
|
|
|
|
|
|
|
|
|
| Else | : | other division of NEC |
|
| p3: | : Unit code | 00 | : | TC5000EX7 | |||||||
|
|
|
|
|
|
|
|
|
|
| 01 | : | TC5000EX10 |
|
|
|
|
|
|
|
|
|
|
| 02 | : | MMVC |
|
|
|
|
|
|
|
|
|
|
| 03 | : | VL128/384 |
|
|
|
|
|
|
|
|
|
|
| 10 | : | MCU5000A |
|
|
|
|
|
|
|
|
|
|
| Else | : | Reserved |
|
| p4: |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| D 7 | D 6 | D 5 | D 4 | D 3 | D 2 | D 1 | D 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| D0: |
| Kanji Display Capability |
|
| 0: Off | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 1: On |
|
| D1: |
| Composite Screen Display Capability 0: Off | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 1: On |
|
| D2: |
| H281 Camera Control Capability | 0: Off | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 1: On |
|
| p5: |
|
|
|
|
Page |