NEC NDA-24233 manual Ndss, Registering My Number

Models: NDA-24233

1 124
Download 124 pages 3.6 Kb
Page 48
Image 48

Console Command List

VisuaLink 128/384 Engineering Guide

3.5 ISDN Registering/Setting Command

NDSS

Registering My Number

5-1

 

 

 

Description:

Registers a local dial number. In a communication, a local dial number is

 

reported to the remote site at a call origination. The local number to report

 

at this time is registered. The number of digit that can be registered is 20

 

digits for dial number and 8 digits for a sub address at a maximum.

Command Format:

NDSS [p1] p2 p3

p1:

L11

: line 1 dial No. 1

 

L12

: line 1 dial No. 2

 

L21

: line 2 dial No. 1

 

L22

: line 2 dial No. 2

 

L31

: line 3 dial No. 1

 

L32

: line 3 dial No. 2

p2:

0-9

: dial Number (within 20 digits)

 

 

: sub address (within 8 digits)

 

*

: dial number/sub address separating code

 

Off

: Registration Deleted

 

Local Dial Format: dial number * Sub Address

p3:

0-9

 

Note 1: If p1 is omitted, the default is L11.

Note 2: If VL128, setting L21 to L32 results in error.

Response:

Normal Response:

OK

 

Error Response:

ERR01

Page 3-22

NDA-24233 Issue 2

Page 48
Image 48