Page 3-40 NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
3.11 Serial Port Control Command
SSIO Setting Serial Port 11-1RSIO Checking Serial Port Setting 11-2
Description: VisuaLink is equipped with two serial ports, and four possible settings:
T120 data conference
Camera control
External console control
User data (Not compliant to T.120)
Command Format: SSIO p1
p1: 1 Serial 1 = T120 Serial 2 = Console
2 Serial 1 = Camera Serial 2 = Console
3 Serial 1 = T120 Serial 2 = Camera
4 Serial 1 = Console Serial 2 = Camera
5 Serial 1 = User data Serial 2 = Console
6 Serial 1 = User data Serial 2 = Camera
Response: Normal Response OK
Error Response: ERR01
Description: Checks the current serial port configuration.
Command Format: RSIO
Response: Normal Response p1 OK
p1: 1 Serial 1 = T120 Serial 2 = Console
2 Serial 1 = Camera Serial 2 = Console
3 Serial 1 = T120 Serial 2 = Camera
4 Serial 1 = Console Serial 2 = Camera
5 Serial 1 = User data Serial 2 = Console
6 Serial 1 = User data Serial 2 = Camera
Error Response: ERR01