Page 3-14 NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
SMMT Sets Audio or Audio/Video Outgoing Mute Setting 2-11RMMT Checking Audio or Audio/VideoOutput Mute Setting 2-12
Description: Sets whether the audio or audio and video outgoing is muted or unmuted
at the start of communication when the V isuaLink automatically answers
or manual answered calls.
Command Format: SMMT p1
p1: ON: Mute outgoing audio or audio and video at the
start of communication
OFF: Donot Mute audio at the start of communication
(Default)
Response: Normal Response: OK
Description: Reads the current M UTED mode setting.
Command Format: RMMT
Response: Normal Response: p1 OK
p1: ON : Mute outgoing audio or audio and
video at the start of communication
OFF : Donot Mute audio at the start of
communication