VisuaLink 128/384 Engineering Guide

Chapter 1

 

 

1.4 Communication Format

Communication between a console and VisuaLink 128/384 is done in a start-stop synchronization of the following format.

Data Format

START

AS

CII

8bit

PTY

STOP

1

2

3

4

5

6

7

8

9

Data Length:

7, 8 bit ASCII code

 

 

 

 

 

Stop Bit:

1 bit

 

 

 

 

 

 

 

Parity:

Even, Odd, NONE parity

 

 

 

 

Baud:

1200, 2400, 4800, 9600bps

 

 

 

 

Note: Default setting for VisuaLink is 9600, 8, none, 1.

To change the default setting use the SSPR command.

A:Connect terminal to VisuaLink Serial 2

B:Set terminal application to: Baud: 9600

Parity: Even

Bit: 8

Stopbit: 1

C:Calculate the Baud, Parity, and Bit

b7

b6

b5

b4

b3

b2

b1

b0

Not in use

Not in use

00 : 1200bps

01 : 2400bps

10 : 4800bps

11 : 9600bps

00: 7 bit EVEN STOP

011 7 bit ODD STOP

10: 8 bit EVEN STOP

11: 8 bit NONE STOP

D: Set system parameter command for the appropriate setting

Example: SSPR 168=21

Means: Your VL in now set up for 2400, 8, EVEN, 1

E: Reset the VL.