VisuaLink 128/384 Engineering Guide | Chapter 1 |
|
|
1.4 Communication Format
Communication between a console and VisuaLink 128/384 is done in a
Data Format
START
AS
CII
8bit
PTY
STOP
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
Data Length: | 7, 8 bit ASCII code |
|
|
|
|
| ||
Stop Bit: | 1 bit |
|
|
|
|
|
|
|
Parity: | Even, Odd, NONE parity |
|
|
|
| |||
Baud: | 1200, 2400, 4800, 9600bps |
|
|
|
|
Note: Default setting for VisuaLink is 9600, 8, none, 1.
To change the default setting use the SSPR command.
A:Connect terminal to VisuaLink Serial 2
B:Set terminal application to: Baud: 9600
Parity: Even
Bit: 8
Stopbit: 1
C:Calculate the Baud, Parity, and Bit
b7
b6
b5
b4
b3
b2
b1
b0
Not in use
Not in use
00 : 1200bps
01 : 2400bps
10 : 4800bps
11 : 9600bps
00: 7 bit EVEN STOP
011 7 bit ODD STOP
10: 8 bit EVEN STOP
11: 8 bit NONE STOP
D: Set system parameter command for the appropriate setting
Example: SSPR 168=21
Means: Your VL in now set up for 2400, 8, EVEN, 1
E: Reset the VL.
Page |