VisuaLink 128/384 Engineering GuideConsole Command List

RMPS

Read Multi-point Conference Operation Status

16-3

Description:

Acquires the multi-point conference status.

Command Format:

RMPS

 

 

Response:

Normal Response p1 p2 p3 p4 p5 p6 OK

 

p1: 1-255

:

local site conference room number

 

p2: 0/1

:

status of acquisition of a right to operate in a local site

 

 

 

1: acquired 0: released

 

p3: 1-255

:

location number of a video being received

 

p4: 0/1

:

local site video transmitting status 0: OFF 1: ON

 

p5: 1-255

:

a number of multi-point conference participants

 

p6: 0/1

:

screen composite capability 0: none 1: yes

Error Response: ERR01

RMMD

Read Multi-point Conference Mode Status

16-4

Description:

Acquires the multi-point conference mode status.

Command Format:

RMMD

Response:

Normal Response p1 OK

p1: 1 : audio switch

2: local site video transmission

3: chairman control

4: selective receive

5: a status of multiple address transmission by operator

Error Response: ERR01