Omega DPS3100 Thermistor LO Voltage, CH ‘X’ Setpoint CH1 RELAY/UNIVERSAL Relay, CH ‘X’ Limit

Page 20

DPS3107

7 Channel Unit

DPS3104

4 Channel Unit

ENTER PASSCODE -- 3254

‘SYS’ Flashing

SYS CH

‘CH’ Flashing

DISPLAY OPTION (Select one)

 

 

SELECT CHANNEL

 

 

 

 

 

 

 

ELAPSED TIME

 

 

 

IP TYPE

 

SCAN

 

 

 

 

 

 

 

 

 

 

HIGH CHANNEL

 

 

 

 

 

 

LOW CHANNEL

 

 

 

 

 

 

DISPLAY DEVN.

 

 

 

 

 

 

CHANNEL DIFF.

MV, V or C Option

 

 

 

 

 

 

-RTD Option

R,S or B Option

-TC Option

-TH Option

(Not Selectable)

(Not Selectable)

‘J’ T/C

THERMISTOR

LO VOLTAGE

RTD 385

‘R’

T/C

CR.AL T/C (K)

 

VOLTAGE

RTD 392

‘S’

T/C

‘T’

T/C

 

CURRENT

 

‘B’

T/C

‘E’

T/C

DISPLAY TIME

RELAY LATCH/NON-LATCH

AUDIO ALARM ON/OFF

COLD JUNCTION

CH. CALIBRATION

VOLTAGE or CURRENT CHS.

CH ON/OFF

DECIMAL POINT

HIGH SCALE

LOW SCALE

OFFSET

TARE

TEMPERATURE CHS.

CH ON/OFF

DEGREE C/F

VOLTAGE RANGE

CURRENT RANGE

Back to ‘SYS CH’

CH ‘X’ SETPOINT

CH1 RELAY/UNIVERSAL RELAY

‘X’ stands for Channel No.

CH ‘X’ LIMIT

RELAY DEADBAND

RELAY NO/NC

ENGINEERING UNIT

Page 19

Image 20
Contents DPS3100 & DPS3200 series Programmable Scanners Setup Channel ConfigurationSystem Configuration Display ModesError Messages and Solutions Mounting Table of ContentsTrouble Shooting Specifications Manual File omga31320404RTD DescriptionDPS3100 & DPS DPS3200 To Display Perform Following Steps How to Display ParametersDisplaying Parameters Elapsed Time Mode Scan ModeMode Function Performed Display ModesTypes of Deviation Displays High/Low Channel ModeDeviation Mode DPS3000 Series is SetupDifference Mode Calibration/Range setting CH Parameter ListDisplay Options Relay Latch/Non-latch Display TimeChannel Configuration Setup for Voltage or Current InputSetup For Low Scale Setup For OffsetSetup For Tare Setup For SetpointSetup for Universal Relay Channel 1 Relay Setup For LimitsSetup For Deadband Setup For Relay Normally Open/ClosedSetup for Thermocouple/ Thermistor/ RTD Inputs Setup ExamplesSetup For Display Time System ConfigurationSetup For Display Options Setup For Relay Latch/Non-Latch Setup for BuzzerSetup For Cold Junction Calibration Setup For Channel CalibrationThermocouple Calibration Procedure Voltage Range Setup for millivolt inputsCurrent Range Setup Correct Range SettingsProgramming Flow Charts PeaksEnter Passcode SYS CHSelect Channel Channel DiffThermistor LO Voltage CH ‘X’ Setpoint CH1 RELAY/UNIVERSAL RelayCH ‘X’ Limit Relay Deadband Relay NO/NC Engineering UnitRate LimitsOutputs Open Collector OptionFIG- 3. Connections & Rear View of Instrument Power Output Connector PIN Assignment Pin # Signal Relay Output Open CollectorFactory Channel settings Trouble ShootingError Messages and Solutions Panel Cutout and mounting hole dimensions MountingWarranty Page