Appendix A - Troubleshooting

Appendix A - Troubleshooting

A Serial Utility Diskette is supplied with the adapter and will be used in the troubleshooting procedures. By using this diskette and following these simple steps, most common problems can be eliminated without the need to call Technical Support.

1.Identify all I/O adapters currently installed in your system. This includes your on-board serial ports, controller cards, sound cards etc. The I/O addresses used by these adapters, as well as the IRQ (if any) should be identified.

2.Configure your adapter so that there is no conflict with currently installed adapters. No two adapters can occupy the same I/O address.

3.Make sure the adapter is using a unique IRQ. While the adapter does allow the sharing of IRQs, many other adapters (i.e. SCSI adapters & on-board serial ports) do not. The IRQ is typically selected via an on-board header block. Refer to the section on Card Setup for help in choosing an I/O address and IRQ.

4.Make sure the adapter is securely installed in a motherboard slot.

5.When running DOS or Windows 3.x refer to the Serial Utilities disk 1 and the User Manual to verify that the adapter is configured correctly. The supplied diskette contains a diagnostic program ‘SSD’ that will verify if an adapter is configured properly. This diagnostic program is written with the user in mind and is easy to use. Refer to the ‘README’ file on the supplied diskette for detailed instructions on using ‘SSD’.

6.For Windows 95 and Windows NT, the diagnostic tool ‘WinSSD’ is installed in the Omega Engineering folder on the Start Menu during the setup process. First find the ports using the Device Manager, then use ‘WinSSD’ to verify that the ports are functional.

7.Always use the diagnostic software when troubleshooting a problem. This will eliminate any software issues from the equation.

OMG-ULTRA-COMM422

Page 19

Image 23
Contents User’sGuide Czech Republic CanadaMexico BeneluxContents Figures What’s Included Factory Default SettingsIntroduction OverviewAddress Selection Card SetupSwitch Port Port # Connector Location Address Example Base=2E0 Switch Settings Address lines à Address SelectedIRQ Selection Jumper SelectionsInterrupt Modes J1ARS-485 Enable Modes Headers J1D- J4D, RS-422 Interface Mode Examples J1D J4DHeaders J1D- J4D, RS-485 ‘RTS’ Enabled, with ‘No Echo’ Name Function Line TerminationDIV4 DIV2 Clock ModesFor this Data Rate Choose this Divisor Baud Rates and Divisors for the ‘Div1’ modeFor this Data Rate Choose this Data Rate Baud Rates and Divisors for the ‘Div2’ mode Other Operating Systems InstallationOperating System Installation For Windows Users Technical Description FeaturesModem Control Signal Considerations Interrupts Why use an ISP? Port # Connector Pin Assignments DB-9 Pin AssignmentsDB-37 Connector Pin Assignments Signal Name Pin # ModeSpecifications Appendix a Troubleshooting OMG-ULTRA-COMM422 Appendix B How To Get Assistance RS-485 Appendix C Electrical InterfaceRS-422 Appendix D Asynchronous Communications Asynchronous Communications Bit DiagramAppendix E Silk-Screen Appendix F Compliance Notices WARRANTY/DISCLAIMER Temperature

RS-422/485 specifications

Omega Engineering is a renowned leader in the field of measurement and control technologies, particularly in the realm of data communication for industrial automation. The RS-422 and RS-485 protocols are part of Omega's robust offering, designed to facilitate reliable and efficient data transmission over relatively long distances. These protocols are widely used in various applications ranging from industrial machinery to building automation systems.

One of the main features of RS-422 is its ability to support long-distance communication, allowing data to be transmitted up to 4,000 feet (approximately 1,200 meters) at speeds of up to 10 Mbps. This is achieved through the use of differential signaling, which provides improved noise immunity compared to single-ended signaling systems. RS-422 employs a single transmitter and multiple receivers, making it ideal for point-to-multipoint configurations.

On the other hand, RS-485 extends the capabilities of RS-422 by allowing multiple devices to be connected on the same bus. It supports up to 32 devices, which can be either transmitters or receivers, making it exceptionally versatile for networking applications. RS-485 can communicate effectively over distances up to 4,000 feet and at speeds of 10 Mbps as well. This makes it an attractive option for applications where several devices need to communicate with a central controller.

An essential characteristic of both protocols is their resilience to electromagnetic interference, which is often a concern in industrial environments. The differential signaling used in RS-422 and RS-485 reduces noise susceptibility, ensuring data integrity even in challenging conditions. Additionally, these protocols function effectively in half-duplex or full-duplex modes, providing flexibility based on application requirements.

Moreover, Omega Engineering’s implementations of RS-422 and RS-485 comply with established standards, ensuring compatibility with a wide range of devices. This interoperability is crucial for seamless integration into existing systems and enhancing overall productivity.

In summary, Omega Engineering's RS-422 and RS-485 technologies offer robust, reliable, and versatile solutions for data communication in industrial settings. With features such as long-distance communication, multiple device connections, and exceptional noise immunity, these protocols continue to serve as foundational technologies in various automation and control applications. As industries evolve, Omega Engineering remains committed to advancing these technologies to meet the growing demands of modern data communication.