Omega LDP-124, LDP-126, LDP-146, LDP-144 Jumpers Configuration, Serial Data Output Configuration

Page 13

10.2.4- JUMPERS CONFIGURATION

 

Function

 

 

 

 

Close Jumper

 

 

 

 

 

 

 

 

220 Ω terminator resistor for the RS422

JP1

(By default opened)

 

switch debounce of 5 Hz for the STOP line

JP2* (By default closed)

 

switch debounce of 5 Hz for the START line

JP3* (By default closed)

 

switch debounce of 5 Hz for the RESET line

JP4* (By default closed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper

Application

 

 

 

A

Jumper position

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JP5

for STOP line

 

1

KΩ

pull-up *

 

 

1 KΩ

pull-down

JP6

for START line

 

falling edge/low level active*

 

rising edge/high level active

JP7

for STOP line

 

falling edge/low level active*

 

rising edge/high level active

JP8

for RESET line

 

falling edge/low level active*

 

rising edge/high level active

JP9

for START line

 

1

KΩ

pull-up*

 

 

1 KΩ

pull-down

JP10

for RESET line

 

1

KΩ

pull-up*

 

 

1 KΩ

pull-down

 

 

 

 

 

 

 

 

 

 

 

*= Factory set-up

10.2.5- SERIAL DATA OUTPUT CONFIGURATION

 

Data output format

Transmission during

Instrument

with DIP switch 7

 

with DIP switch 7

 

time adjust or in

reference

in position ON

 

in position OFF

 

alarm status

 

(NEWPORT mode)

 

Standard mode

 

 

 

 

 

 

 

 

C2

HHM.MS.S(CR)

 

HH.MM.SS(CR)

--(NUL)--(NUL)--(CR)

C1

HHM.M(CR)

 

HH.MM(CR) *

--(NUL)--(CR)

 

 

 

HH(NUL)MM(CR)**

 

C0

MMS.S(CR)

 

MM.SS(CR)

--(NUL)--(CR)

 

 

 

 

 

*= Data output format only when the colon is lighted.

**= Data output format only when the colon is NOT lighted.

H = Character from "0" to "9" which represent one number of hours.

M = Character from "0" to "9" which represent one number of minutes.

S = Character from "0" to "9" which represent one number of seconds.

Character "." = 02E hex.

Character "-" = 02D hex.

Character "(NUL)" = 0 hex.

Character "(CR)" = 0D hex.

Page : 12

Image 13
Contents Users Guide USA Contents Precautions Important Safety ConsiderationsSafety Prescriptions PrescriptionsENGINEERING´S customer service department Main FeaturesUnpacking and Inspection Model LDP-1XX-C1. Display time using the format HH MM ResetModels ConnectionsGeneral Specifications Rear VIEW, Description for all series Front VIEW, DescriptionPower SUPPLY, Recommended Wiring WiringControl LINES, Alarm and Serial Output Protection FusesExcitation Voltage for Sensors POWER-UP and OperationRUN Time Clock Configuration DIP Switch Configuration DIP Switch and Jumpers LocationControl Board Position Display brightness tableSerial Data Output Configuration Jumpers ConfigurationMechanical Dimensions mm inches InstallationAppendix 1 Model LDP-1XX-CX AS Slave Repeater Configuration OptionsFunctional Description OperationMaster It is advisable to make the TIME-NET connections as followsSlave Return REQUESTS/INQUIRIES WARRANTY/DISCLAIMERPRESSURE, Strain and Force TemperatureFLOW/LEVEL Data Acquisition