Omega LDP-144, LDP-126, LDP-124, LDP-146 manual Configuration

Page 11

9.2.2.- CONNECTION EXAMPLES

Different interlinking of the three control lines will produce different operating modes:

Stop

Start

Reset

GND

Stop

Start

Reset

GND

Stop

Start

Reset

GND

B

B

A

Close contact A = reset and run Open contact A = stop

AWith contact B opened close contact A = run open contact A = stop

push contact B = reset

A

Push A = start

Push A = stop

Push B = reset

Stop

Start

Reset

GND

Stop

Start

Reset

GND

C B

B

A

Push B = start A Push A = stop Push C = reset

note A may close while B is shut

B may open while A is shut

Push A = reset and start Push B = stop

(push B again = start)

9.3.- RUN TIME ALARM SETTING

The alarm is a 4 decade alarm only. On the 6 decade clock, the alarm setting is for hours and minutes only and on the 4 decade clock the alarm point can be for either hours and minutes or minutes and seconds.

Displaying or setting of the alarm point can only be done when the unit is displaying the run time and is not running.

The same three contact inputs are used for setting the alarm point and for adjusting the real time clock, but their functions are different.

To display the alarm set point, hold the SECONDS input (pin 13) to GND. Once the alarm point is displayed, the value can be changed by contact closure between GND and the following terminals :

Seconds

view/adjust alarm point ( hold to GND).

Minutes

increment seconds ( or minutes).

Hours

increment minutes ( or hours).

Hours and Minutes

together reset alarm to zero

9.4.- SERIAL DATA OUTPUT

The unit incorporates and RS422 level serial ASCII output to allow master/slave clock setups in conjunction with serial ASCII remote displays.

Details of the serial output to be found in paragraph 5.

Note the line should be terminated to prevent noise pickup if the clock is not transmitting data.

10.- CONFIGURATION

10.1.- POWER SELECTION

See the rear label for power requirements. Power supply selection must be done by suitable qualified personnel or by the local distributor. Contact factory or your local distributor for instructions.

10.2.- INSTRUMENT CONFIGURATION

To change the instrument configuration, the rear panel of the instrument needs only to be removed to gain access to the internal DIP switches and jumpers located on the control board.

Be sure that the instrument is disconnected from any power supply before removing the rear panel.

Page : 10

Image 11
Contents Users Guide USA Contents Prescriptions Important Safety ConsiderationsPrecautions Safety PrescriptionsUnpacking and Inspection Main FeaturesENGINEERING´S customer service department Connections ResetModel LDP-1XX-C1. Display time using the format HH MM ModelsGeneral Specifications Rear VIEW, Description for all series Front VIEW, DescriptionProtection Fuses WiringPower SUPPLY, Recommended Wiring Control LINES, Alarm and Serial OutputRUN Time Clock POWER-UP and OperationExcitation Voltage for Sensors Configuration Display brightness table DIP Switch and Jumpers LocationDIP Switch Configuration Control Board PositionSerial Data Output Configuration Jumpers ConfigurationMechanical Dimensions mm inches InstallationOperation Configuration OptionsAppendix 1 Model LDP-1XX-CX AS Slave Repeater Functional DescriptionSlave It is advisable to make the TIME-NET connections as followsMaster Return REQUESTS/INQUIRIES WARRANTY/DISCLAIMERData Acquisition TemperaturePRESSURE, Strain and Force FLOW/LEVEL