Omega LDP-144 Appendix 1 Model LDP-1XX-CX AS Slave Repeater, Functional Description, Operation

Page 15

APPENDIX 1: MODEL LDP-1XX-CX AS SLAVE REPEATER.

FUNCTIONAL DESCRIPTION:

Special configuration of Models LDP-1XX-CXfor serial RS-422repeater, to be used as slaves.

The Serial port connection which is the only that keeps in operation, it is used to enter the data coming from the Master.

The rest of functions and connections of these Models, remain disabled.

CONFIGURATION OF A SLAVE MODEL, STARTING FROM A MASTER MODEL LDP-1XX-CX:

- Remove the integrated circuit "IC4" placed on the PCB "98/04" and close jumper JPA2.

CONFIGURATION OPTIONS:

Jumper JP1 placed on PCB "98/06", connects the RS-422line termination (220 Ohm.).

The rest of the Mini-dips and Jumpers are disabled on this Mode.

JP1

Charge connected

Charge disconnected

JP1

C.I.98/04

C.I.98/06

1137A

REMOVE IC4

SITUATION JUMPER JPA2

 

MALAYSIA

BATTERY

LITHIUM

 

RAM IMEKEEPER T

 

200PC1-M48T02

 

TS

 

JPA2

 

JPA3

JPA4

Configuration Diagram.

OPERATION:

After powered up the unit, the 4 digit Models will display "SLU" and the 6 digit Models will display "SLAUE". These above indications will remain on the Display, until to receive valid data through RS-422channel.

Page : 14

Image 15
Contents Users Guide USA Contents Prescriptions Important Safety ConsiderationsPrecautions Safety PrescriptionsMain Features ENGINEERING´S customer service departmentUnpacking and Inspection Connections ResetModel LDP-1XX-C1. Display time using the format HH MM ModelsGeneral Specifications Rear VIEW, Description for all series Front VIEW, DescriptionProtection Fuses WiringPower SUPPLY, Recommended Wiring Control LINES, Alarm and Serial OutputPOWER-UP and Operation Excitation Voltage for SensorsRUN Time Clock Configuration Display brightness table DIP Switch and Jumpers Location DIP Switch Configuration Control Board PositionSerial Data Output Configuration Jumpers ConfigurationMechanical Dimensions mm inches InstallationOperation Configuration OptionsAppendix 1 Model LDP-1XX-CX AS Slave Repeater Functional DescriptionIt is advisable to make the TIME-NET connections as follows MasterSlave Return REQUESTS/INQUIRIES WARRANTY/DISCLAIMERData Acquisition TemperaturePRESSURE, Strain and Force FLOW/LEVEL