5.- GENERAL SPECIFICATIONS

DISPLAY

Type

4 or 6 digits, 7 segments, red or green LED.

Height digit

57 (2.3") or 100 mm. (4")

Range máx

99 : 59 or 99 :59 : 59

Brightness

Set by switch for 25%, 50%, 75%

 

or 100% (normal).

REAL TIME CLOCK.

Type . . . . . . . . . . . . . . . . . 59 mm 59 ss (model C0) 12/24 hours selectable

Time setting . . . . . . . . . . . . By volt free contact closure inputs seconds reset, minutes advance and hours advance.

Time accuracy . . . . . . . . . . ±1 minute per month.

Power down . . . . . . . . . . . . Maintains time for minimum 2 years without mains power.

RUN TIME CLOCK

OUTPUTS

SERIAL OUTPUT . . . . . . . Output intended for transmission to the remote display fitted with a clock display as a slave clock display.

Signal . . . . . . . . . . . . . . . . RS422 level 1200 baud fixed rate. One transmission each second while showing real time or run time.

String . . . . . . . . . . . . . . . . . Transmits --NUL--(CR)

or --NUL--NUL--(CR) when setting time or entering alarm state.

Data string

Standard mode

. . . . . HH.MM.SS for 6 decade version.

 

HH.MM or MM.SS for 4 decade version.

Newport mode .

. . . . . HHM.MS.S for 6 decade version.

 

HHM.M or MMS.S for 4 decade version.

Character length . . .

. . . . . One start bit, 8 data bits no parity and

 

one stop bit.

Handshake

. . . . . No handshake : one data string

Type . . . . . . . . . . . . . . . . .

Timer resolution . . . . . . . . .

Timer uncertainty . . . . . . . .

Timer memory . . . . . . . . . .

Alarm . . . . . . . . . . . . . . . . .

external closure inputs. Alarm enable . . . . . . . . . . .

Alarm output . . . . . . . . . . .

Alarm indication . . . . . . . . .

Initialization . . . . . . . . . . . .

99 mm 59 ss, 99 hh 59 mm or 99 hh 59 mm 59 ss

1 second.

1 second max. per start/stop sequence. Run time maintained for 2 years minimum but not updated with mains removed. One minute or one second resolution (one minute only on model C2) set by

Controlled by internal switch. Optically isolates transistor switch 30 V / 30 mA capacity.

Clock stop, display flashes and alarm output activates.

By operation of one or more the control inputs.

transmitted each second.

EXCITATION VOLTAGE OUTPUT

Vexc . . . . . . . . . . . . . . . . . +15 Vdc ±20%. @100 mA. max. Ripple . . . . . . . . . . . . . . . . 100 mVac 50/60 Hz.

ENVIRONMENTAL

Temperature

 

Operating . . . .

0 to +50 ºC (32 to 122 ºF).

Storage

-20 to +85 º C (-4 to 185 ºF).

Relative humidity

0 to 85 % not condensed.

CONTROL LINES

Type

Three inputs sharing one common return.

Threshold

Rising : +2.3 V min., +3.6 V max.

 

Falling : +0.9 V min., +2.5 V max.

Signal hysteresis

0.4 V minimum.

Maximum signal

±30 V.

Loading

100 KΩ to common for +5 V signal

 

18 KΩ loading beyond +5/-0.6V.

Load

1 KΩ ±5% load may be internally

 

jumpered to common or to the excitation

 

supply for each control line.

Response time

200 mS maximum: internally

 

debounced for contact closure inputs.

Active level

Internally jumpered to be active either with

 

low level/falling edge or high level/rising

 

edge inputs independently for each

 

control line.

CONTROL MODES

 

Type

The operating mode depends on

 

interlinking of the three control lines.

One control

To reset and run when active and stop

 

when inactive.

Two controls

One to run when active and stop when

 

inactive and the other to reset.

Two controls

One to alternately start and stop and the

 

other to reset.

Three controls

One to start, one to stop and one to

 

reset.

Protection

IP65. (Front part only).

MECHANICAL

 

Dimensions . . . . . . . . . . . . See table in page 13. Panel cut out . . . . . . . . . . . See table in page 13. Depth . . . . . . . . . . . . . . . . . See table in page 13. Weight . . . . . . . . . . . . . . . . See table in page 13. Case material . . . . . . . . . . . Aluminium extruded.

Finished . . . . . . . . . . . . . . . Anodized, black colour.

ELECTRICAL

Standard power supply

. . . 115 Vac. ±10% 50 / 60 Hz.

 

(230 Vac optionally)

Consumption

. . . See table in page 13.

Page : 6

Image 7
Contents Users Guide USA Contents Prescriptions Important Safety ConsiderationsPrecautions Safety PrescriptionsENGINEERING´S customer service department Main FeaturesUnpacking and Inspection Connections ResetModel LDP-1XX-C1. Display time using the format HH MM ModelsGeneral Specifications Rear VIEW, Description for all series Front VIEW, DescriptionProtection Fuses WiringPower SUPPLY, Recommended Wiring Control LINES, Alarm and Serial OutputExcitation Voltage for Sensors POWER-UP and OperationRUN Time Clock Configuration Display brightness table DIP Switch and Jumpers LocationDIP Switch Configuration Control Board PositionSerial Data Output Configuration Jumpers ConfigurationMechanical Dimensions mm inches InstallationOperation Configuration OptionsAppendix 1 Model LDP-1XX-CX AS Slave Repeater Functional DescriptionMaster It is advisable to make the TIME-NET connections as followsSlave Return REQUESTS/INQUIRIES WARRANTY/DISCLAIMERData Acquisition TemperaturePRESSURE, Strain and Force FLOW/LEVEL