Omega Engineering OM-DAQ-USB-2401 manual Configuration Parameter Settings

Page 27

Software 4

Configuration Parameter Settings

Channel

The input channel’s name (not editable)

 

AN1D = analog channel 1, differential input

 

AN1H = analog channel 1, single-ended high input

 

AN1L = analog channel 1, single-ended low input

 

Etc.

 

 

Nickname

You can specify the Nickname (e.g., Oven 1, Monitor

 

Room)

 

 

Units

You can specify the Engineering Unit. When switching

 

between voltage and thermocouple ranges, this will

 

automatically switch to the default units for that range.

 

However, any units label may be typed in here.

 

 

On/Off

To turn on or turn off the selected input channel

 

 

Single/Diff

You can select input channel as Single-ended or

 

Differential input.

 

 

Range

You can select the voltage input range or thermocouple

 

type for each input channel. Thermocouples must

 

always be used with Differential input.

 

 

Scale and

You can rescale the input signal. This scaled/offset

Offset

value will appear in all data displays, and in any saved

 

data files.

 

 

Sampling can be set in terms of “Scan Rate” or “Scan Time”.

Scan Rate = 1/(Scan Time).

For example, if you are acquiring 4 voltage inputs at 250 Hz, you will receive 250 complete scans per second. Meaning each channel will send 250 pieces of data every second, for a total of (4 x 250) = 1000 pieces of data.

The maximum scan rate is affected by the number of channels turned on. Selecting thermocouple input also lowers the maximum scan rate.

Figure 4-10. Scan Options

Figure 4-11. Units Options

Figure 4-12. Automatic Calibration

4-9

Image 27
Contents OM-DAQ-USB-2401 Servicing North America OM-DAQ-USB-2400 Multiple Channel USB Data Acquisition Module International Usage and CE Marking 10-1 OM-DAQ-USB-2400Section List of FiguresExamples of Under Sampling Introduction PrecautionsSafety Warnings and IEC Symbols Statement on CE MarkingGeneral Description & System Components System Components Hardware Package InspectionIncluded Items Hardware Setup USB Hubs and Power AdaptorsOM-DAQ-USB-2401 System Components USB-powered Hubs Self-powered HubsPower Adaptors Connecting Your OM-DAQ-USB-2401 Acquisition System to PC Direct Connection to Computer USB Ports Connecting Various Hardware SetupsConnections to Self-Powered and USB-powered Hubs Connection to USB-powered HubOM-DAQ-USB-2401 Mounting Connections to Self-Powered Hub and to USB-Powered HubOM-DAQ-USB-2400 Series OM-DAQ-USB-2401 Wall MountingOM-DAQ-USB-2401 Rail Mounting OM-DAQ-USB-2401 DIN Rail MountingSystem Requirements Software InstallationSoftware Getting StartedWelcome Screen Software SetupConfirm Installation Screen Main Control Window DAQ Central Software OperationToolbar Buttons Toolbar ButtonsFile Menu Main Control Window Pull-Down OperationsTools Menu Channels Tab 2 Device ConfigurationConfiguration Parameter Settings Manual Acquisition is manually started/stopped Level Data Displays Data Tab18. Main Window Screen 23. Waveform Screen Power Line Rejection Optical IsolationA/D Conversion Input Ranges Analog Input ConfigurationMeasurement Duration, Scan Time, and Resolution 27. Calibration/Scan Arrangement Automatic CalibrationThermocouple Measurements 28. Thermocouple WiringChannel Control and Expansion Signal ManagementScan Time and Resolution Resolution Effective Number of Bits ENOB, RMSRMS Under Sampling and AliasingExamples of Under Sampling SignalTriggering Signal ModesNoise Reduction in Differential Mode System Noise AveragingAnalog Filtering = RC Input and Source ImpedanceCrosstalk Vadc = VT x Ri / Rs + RiOM-DAQ-USB-2401 Design for CE Conformity CE ConformityFerrite Core Troubleshooting Basic ChecklistSymptoms and Solutions Service & Calibration Service & CalibrationSpecifications Cold Junction Power SupplyExternal Power Source Thermocouple Input RangeTC Type Temp Typical Fast Slow Thermocouple Accuracy ºC for OM-DAQ-USB-2401International Usage & CE Marking Approvals and Regulatory Compliance10-2 10-3 10-4 WARRANTY/DISCLAIMER Temperature