NetComm IG6000 manual General Commands

Page 14

Industrial Modem User Guide

General Commands

+++

 

Escape Sequence

?

 

Displays help. May be followed by the command(s) or a keyword for which

 

 

help is needed

A/

 

Repeat Command

B0

n

Auto­Connect

B1

 

Auto­Connect

B2

 

Auto­Connect

B3

 

V.21 ­ 300 bps

B4

 

Bell 103 ­ 300 bps

B5

 

V.23 ­ 1200/75 bps

B6

 

V.22 ­ 1200 bps

B7

 

Bell 212A ­ 1200 bps

B8

 

V.22bis ­ 2400 bps

B9

 

Auto­Connect

B10

 

V.32 ­ 4800 bps

B11

 

V.32bis ­ 7200 bps

B12

 

V.32 (Non­TCM) ­ 9600 bps

B13

 

V.32 ­ 9600 bps

B14

 

V.32bis ­ 12000 bps

B15

 

V.32bis ­ 14400 bps

B16

 

V.34/V.Fast Class ­ 14400 bps

B17

 

V.34/V.Fast Class ­ 16800 bps

B18

 

V.34/V.Fast Class ­ 19200 bps

B19

 

V.34/V.Fast Class ­ 21600 bps

B20

 

V.34/V.Fast Class ­ 24000 bps

B21

 

V.34/V.Fast Class ­ 26400 bps

B22

 

V.34/V.Fast Class ­ 28800 bps

B23

 

V.34 31200 bps

B24

 

V.34 33600 bps

E0

 

Local command state echo off

E1

n

Local command state echo on

H0

 

Go on­hook

H1

 

Go off­hook

I0

 

Numeric firmware identity

I1

 

Checksum of firmware ­ return checksum

I2

 

Checksum of firmware ­ return OK/ERROR

I3

 

Modem Model

I4

 

Firmware Version and date

I5

 

Manufacturer ID

I9

 

Verbal firmware identity

I10

 

Display modem statistics

L0

 

Lowest volume level

L1

 

Low volume level

L2

n

Medium volume level

L3

 

Highest volume level

M0

 

Speaker is always off

M1

n

Speaker on when connecting, off when connected

M2

 

Speaker always on

M3

 

Speaker off when dialling or after connection established

YML391­3A

14

Image 14
Contents Industrial Modem Table of Contents TeleMarketing Contact InformationTechnical Support Mailing ListAustralian Customer Information Legal & Regulatory InformationCopyright Information New Zealand Customer InformationIndustrial Modem User Guide Introduction Pstn Modem Controls and IndicatorsLinks Internal controls OUTDial and Talk Feature Modem FeaturesPower Down Feature AT#MEM1 How to Load the Voice Alarm MessagesVoice Messaging System AT#MEM2Remote Voice Setting of Alarm Messages Operating Modes Asynchronous ModeSynchronous Mode Line SpeedsLeased Line Operation Dial Modifiers Modem AT CommandsCommands General Commands Speaker on during dial, answer, retrain or rate change #MEM2 #MEM0#MEM1 #MINIIndustrial Modem User Guide Modulation Setting Mod Modulation Possible Rates bpsAT­SDR=7 Distinctive RingAT­SDR=0 Response Codes Registers AsciiSpecifications Environmental Data CompressionEncryption Humidity

IG6000 specifications

The NetComm IG6000 is a cutting-edge industrial-grade router designed to meet the growing demands of IoT applications, industrial automation, and remote monitoring. Built for robustness and reliability, the IG6000 caters to sectors such as manufacturing, transportation, and utilities, where stable connectivity is paramount for operational efficiency.

One of the defining features of the IG6000 is its versatility. It supports multiple connectivity options, including 4G LTE, Ethernet, and Wi-Fi, ensuring that devices remain connected even in challenging environments. The integrated cellular connectivity enables organizations to extend their networks to remote locations without the need for costly infrastructure. This makes the IG6000 an ideal choice for applications like smart cities, remote asset management, and telemetry systems.

The router’s rugged design is another standout characteristic. Designed to withstand extreme temperatures, dust, and moisture, the IG6000 is compliant with IP30 standards, ensuring that it can operate effectively in industrial settings. Its durability minimizes the risk of downtime, a crucial factor for businesses that rely on continuous data transmission and real-time insights.

Security is paramount in industrial environments, and the IG6000 addresses this with advanced features such as built-in firewalls, VPN support, and secure encryption protocols. These security measures help to protect sensitive data and ensure compliance with industry standards.

The IG6000 also boasts extensive configuration capabilities. Users can customize network settings and manage connected devices through a user-friendly interface. Additionally, the router supports cloud management, providing IT teams with the ability to monitor performance remotely and make necessary adjustments in real time.

Another significant aspect of the IG6000 is its support for edge computing. By enabling data processing at the edge of the network, organizations can achieve faster response times and reduced latency. This is particularly beneficial for applications that require immediate processing, such as predictive maintenance systems or real-time inventory management.

Lastly, the NetComm IG6000 is designed with scalability in mind. Businesses can seamlessly integrate additional devices and sensors as their operations grow, making it a future-proof solution. Overall, the IG6000 stands out as a reliable, secure, and efficient router, perfectly positioned to support the evolving landscape of industrial connectivity and IoT applications.