NetComm IG6000 manual #MEM0, #MEM1, #MEM2, #Mini

Page 16

Industrial Modem User Guide

&F1

 

Restore non­error correction factory defaults

&F.

 

Reset modem (clear security database/Telephone numbers)

&G0

n

No guard tone generated

&G1

 

550 Hz guard tone generated

&G2

 

1800 Hz guard tone generated

&K0

 

Flow control disabled

&K3

 

RTS/CTS flow control

&K4

 

XON/XOFF flow control

&K5

 

Transparent XON/XOFF flow control

&K9

n

Failsafe flow control

&M0

n

Asynchronous mode

&N0

 

Abort dial character disabled

&N1

n

Abort dial character enabled

&P0

 

39/61 make/break ratio (USA)

&P1

n

33/67 make/break ratio (Aus/UK)

&S0

 

DSR signal always asserted

&S1

n

DSR signal asserted at start of handshake

&S2

 

DSR signal asserted at end of handshake (before CONNECT message)

&T0

 

Terminate current test

&T1

 

Local Analogue Loopback test

&T3

 

Local Digital Loopback test

&T4

n

Grant Remote Digital Loopback test

&T5

 

Deny Remote Digital Loopback test

&T6

 

Remote Digital Loopback test

&T7

 

Remote Digital Loopback with Self­test

&T8

 

Local Analog Loopback with Self­test

&V

 

View active configuration profile

&Vn

 

View stored profile (n=0­3)

&V8

 

View differences between active and default

&Wn

 

Save current configuration into stored profile n (n=0,1,2,3)

&Yn

 

Select stored profile n for Power on and &D3

&Zn=x

 

Store x as phone number n (x=0­9)

#A0

 

Prevent Remote Access

#A1

 

Allow remote access

#A2

n

Allow remote access with security password

#ALMn=x

 

Dial number/s x (x=0­9 in &Z) for remote alert n

#B0

n

In 1200bps originate mode B0=V.23, B2=V.22

#B1

 

In 1200bps originate mode B0=V.22, B2=V.23

#C0

 

V.25 calling tones disabled

#C1

n

V.25 calling tones enabled

#J0

 

Assume V.42 compatibility

#J1

n

Check V.42 compatibility

#K0

 

Disable MNP 10

#K1

n

Enable MNP 10

#K2

 

Enable MNP 10 for Cellular links

#MEM0

 

All voice features off

#MEM1

n

Voice mode after S110 rings if DTR is low

#MEM2

 

Voice mode after S110 rings regardless of DTR

#MINI

 

Erase Voice mode alarm message

#M0

n

AT command operation

#O0

n

Characters ignored if modem buffers overflow

YML391­3A

16

Image 16
Contents Industrial Modem Table of Contents Contact Information Technical SupportTeleMarketing Mailing ListLegal & Regulatory Information Copyright InformationAustralian Customer Information New Zealand Customer InformationIndustrial Modem User Guide Introduction Modem Controls and Indicators Links Internal controlsPstn OUTPower Down Feature Modem FeaturesDial and Talk Feature How to Load the Voice Alarm Messages Voice Messaging SystemAT#MEM1 AT#MEM2Remote Voice Setting of Alarm Messages Asynchronous Mode Synchronous ModeOperating Modes Line SpeedsLeased Line Operation Commands Modem AT CommandsDial Modifiers General Commands Speaker on during dial, answer, retrain or rate change #MEM0 #MEM1#MEM2 #MINIIndustrial Modem User Guide Modulation Setting Mod Modulation Possible Rates bpsAT­SDR=0 Distinctive RingAT­SDR=7 Response Codes Registers AsciiSpecifications Data Compression EncryptionEnvironmental Humidity

IG6000 specifications

The NetComm IG6000 is a cutting-edge industrial-grade router designed to meet the growing demands of IoT applications, industrial automation, and remote monitoring. Built for robustness and reliability, the IG6000 caters to sectors such as manufacturing, transportation, and utilities, where stable connectivity is paramount for operational efficiency.

One of the defining features of the IG6000 is its versatility. It supports multiple connectivity options, including 4G LTE, Ethernet, and Wi-Fi, ensuring that devices remain connected even in challenging environments. The integrated cellular connectivity enables organizations to extend their networks to remote locations without the need for costly infrastructure. This makes the IG6000 an ideal choice for applications like smart cities, remote asset management, and telemetry systems.

The router’s rugged design is another standout characteristic. Designed to withstand extreme temperatures, dust, and moisture, the IG6000 is compliant with IP30 standards, ensuring that it can operate effectively in industrial settings. Its durability minimizes the risk of downtime, a crucial factor for businesses that rely on continuous data transmission and real-time insights.

Security is paramount in industrial environments, and the IG6000 addresses this with advanced features such as built-in firewalls, VPN support, and secure encryption protocols. These security measures help to protect sensitive data and ensure compliance with industry standards.

The IG6000 also boasts extensive configuration capabilities. Users can customize network settings and manage connected devices through a user-friendly interface. Additionally, the router supports cloud management, providing IT teams with the ability to monitor performance remotely and make necessary adjustments in real time.

Another significant aspect of the IG6000 is its support for edge computing. By enabling data processing at the edge of the network, organizations can achieve faster response times and reduced latency. This is particularly beneficial for applications that require immediate processing, such as predictive maintenance systems or real-time inventory management.

Lastly, the NetComm IG6000 is designed with scalability in mind. Businesses can seamlessly integrate additional devices and sensors as their operations grow, making it a future-proof solution. Overall, the IG6000 stands out as a reliable, secure, and efficient router, perfectly positioned to support the evolving landscape of industrial connectivity and IoT applications.