NetComm IG6000 manual Modulation Setting, Mod Modulation Possible Rates bps

Page 18

Industrial Modem User Guide

\J0

n

Fallback to direct mode disabled

\J1

 

Fallback to direct mode enabled

\Kn

 

Received Break control (default \K5)

\N0

 

Constant speed mode

\N1

 

Variable speed mode

\N2

 

MNP reliable mode

\N3

n

V.42/MNP auto­reliable mode

\N4

 

V.42 reliable mode

\N5

 

V.42 auto­reliable mode

\N6

 

V.42/MNP reliable mode, fallback to MNP reliable mode

\N7

 

MNP auto­reliable mode

\Q0

 

Flow control disabled

\Q1

 

XON/XOFF flow control from modem and computer

\Q2

 

CTS flow control

\Q3

 

CTS­RTS flow control (same as &K3)

\Q4

 

Modem­only XON/XOFF flow control

\Q5

 

CTS flow control (CTS low until connection)

\Q6

 

CTS­RTS flow control ­ CTS low until connect

\S

 

Display active configuration with detailed description

\Tn

 

Set inactivity timer to n seconds (Default \T0)

\V0

n

Disable reliable response codes

\V1

 

Enable reliable response codes

\V8

 

Extended response codes

\V9

 

Extended response codes with diagnostic information

\X0

n

XON/XOFF pass through disabled

\X1

 

XON/XOFF pass through enabled

*C0

n

Enable V.34

*C1

 

Disable V.34 use V.FC

*Wttt...tt

 

Specify welcome message text used by %W1(ttt...tt = text use for new line)

Modulation Setting

+MS?

 

Report selected options

+MS=?

 

Report list of supported options

+MS=

 

<mod>,<automode>,<min_rate>,<max_rate><E>

<mod>

 

see table

<automode>

=0 (automode disabled, fixed modulation)

<automode>

=1 (automode enabled, auto select speed/mod)

<min_rate>

=lowest rate for modem connection

<max_rate>

=highest rate for modem connection

<mod>

Modulation

Possible Rates (bps)

0

V.21

300

1

V.22

1200

2

V.22bis

2400 or 1200

3

V.23

1200

9

V.32

9600 or 4800

10

V.32bis

14400, 12000, 9600, 7200,or 4800

11 n

V.34

33,600, 31,200, 28800, 26400, 24000, 21600, 19200, 16800, 14400, 12000,

 

 

9600, 7200, 4800, or 2400

64

Bell 103

300

69

Bell 212

1200

YML391­3A

18

Image 18
Contents Industrial Modem Table of Contents TeleMarketing Contact InformationTechnical Support Mailing ListAustralian Customer Information Legal & Regulatory InformationCopyright Information New Zealand Customer InformationIndustrial Modem User Guide Introduction Pstn Modem Controls and IndicatorsLinks Internal controls OUTModem Features Power Down FeatureDial and Talk Feature AT#MEM1 How to Load the Voice Alarm MessagesVoice Messaging System AT#MEM2Remote Voice Setting of Alarm Messages Operating Modes Asynchronous ModeSynchronous Mode Line SpeedsLeased Line Operation Modem AT Commands CommandsDial Modifiers General Commands Speaker on during dial, answer, retrain or rate change #MEM2 #MEM0#MEM1 #MINIIndustrial Modem User Guide Modulation Setting Mod Modulation Possible Rates bpsDistinctive Ring AT­SDR=0AT­SDR=7 Response Codes Registers AsciiSpecifications Environmental Data CompressionEncryption Humidity

IG6000 specifications

The NetComm IG6000 is a cutting-edge industrial-grade router designed to meet the growing demands of IoT applications, industrial automation, and remote monitoring. Built for robustness and reliability, the IG6000 caters to sectors such as manufacturing, transportation, and utilities, where stable connectivity is paramount for operational efficiency.

One of the defining features of the IG6000 is its versatility. It supports multiple connectivity options, including 4G LTE, Ethernet, and Wi-Fi, ensuring that devices remain connected even in challenging environments. The integrated cellular connectivity enables organizations to extend their networks to remote locations without the need for costly infrastructure. This makes the IG6000 an ideal choice for applications like smart cities, remote asset management, and telemetry systems.

The router’s rugged design is another standout characteristic. Designed to withstand extreme temperatures, dust, and moisture, the IG6000 is compliant with IP30 standards, ensuring that it can operate effectively in industrial settings. Its durability minimizes the risk of downtime, a crucial factor for businesses that rely on continuous data transmission and real-time insights.

Security is paramount in industrial environments, and the IG6000 addresses this with advanced features such as built-in firewalls, VPN support, and secure encryption protocols. These security measures help to protect sensitive data and ensure compliance with industry standards.

The IG6000 also boasts extensive configuration capabilities. Users can customize network settings and manage connected devices through a user-friendly interface. Additionally, the router supports cloud management, providing IT teams with the ability to monitor performance remotely and make necessary adjustments in real time.

Another significant aspect of the IG6000 is its support for edge computing. By enabling data processing at the edge of the network, organizations can achieve faster response times and reduced latency. This is particularly beneficial for applications that require immediate processing, such as predictive maintenance systems or real-time inventory management.

Lastly, the NetComm IG6000 is designed with scalability in mind. Businesses can seamlessly integrate additional devices and sensors as their operations grow, making it a future-proof solution. Overall, the IG6000 stands out as a reliable, secure, and efficient router, perfectly positioned to support the evolving landscape of industrial connectivity and IoT applications.