Multi-Tech Systems MT56DSU-S manual Appendix a Application Examples, Introduction

Page 29

Appendix

Appendix A - Application Examples

Introduction

This section illustrates several types of applications in which the MT56DSU-S is typically used. These types include:

Local Area Data Set

DDS point-to-point application

DDS multipoint (polled) application

Local Area Data Set Application

In this application, two pairs of wires provide the connection between two MT56DSU-S devices. The two pairs can be up to the equivalent of 3 miles of AWG #26 wire at 56 Kbps, or longer for subrate applications.

The figure below depicts a typical Local Area Data Set application.

Up to 3 miles

of AWG 26 wire

@ 56 Kbps

DTE

DSU

DSU

DTE

(Requires two pairs

of interconnection wires)

Figure A-1. Local Area Data Set Application

DDS Point-To-Point Application

In this application, the MT56DSU-S provides the interface between the DDS line and the DTE at your site. Your network provider will provide (at your request) a DDS line connecting the desired locations. The figure below depicts a sample DDS Point-to-point application.

DDS

Network

DTE

DSU

DSU

DTE

Figure A-2. DDS Point-to-Point Application

29

Image 29
Contents User Guide MT56DSU-S Syncronous 56K bps Data Service UnitRevision Date Description Contents Service & Warranty Introduction About This Manual IntroductionCSU/DSU Basics DescriptionDSU Functions CSU FunctionsFeatures Specifications Front & Back Panel Descriptions Front Panel Front Panel2 RS232 Connector Power ConnectorLine Connector Back PanelSwitch Settings Mode Position Description Switch SettingsShunts ShuntsUnpacking & Setup Unpacking Telecom Safety WarningsBack Panel Connections SetupV.35 Shunt Diagnostics Loopback Test Loopback Test DiagramDSU Loopback Test Line Loopback TestDSU Back-to-Back Test DSU Back-to-Back Test DiagramService & Warranty 2 U.S. and Canadian Customers Multi-Tech Systems, Inc. Warranty & Repairs PoliciesWarranty International Distributors International Customers outside U.S.A. and CanadaRepairs Repair Procedures for U.S. and Canadian CustomersRepair Procedures for International Customers Internet Site Technical SupportAppendix Introduction Appendix a Application ExamplesLocal Area Data Set Application DDS Point-To-Point ApplicationFigure A-3. DDS Multipoint Polled Application DDS Multipoint Polled ApplicationRJ-48 Connector Appendix B Interface Signals and Connector PinoutsPin Description Signal DB25S ConnectorPin Description DB25S Connector with V.35 InterfaceBuild Instructions Loopback Cable MTS P/NBack-To-Back Cable MTS P/N Figure B-7. Back-toBack Cable ConnectorFCC Regulations for Telephone Line Interconnection Appendix C Regulatory InformationCanadian Limitations Notice S000327A