Multi-Tech Systems MTCBA-G-EN-FX, MTCBA-E-EN, MTCBA-C-EN-NX Specifications, AT Command Information

Page 8

 

 

 

Chapter 1 – Introduction and Product Description

Specifications

 

 

 

 

 

 

 

 

Features

EDGE Modems

GPRS Modems

CDMA Modems

 

Performance

EDGE: E-GPRS Class 10,

GPRS Class 10

CDMA2000 1xRTT

 

 

GPRS: Class 12

 

 

 

Band,

Quad-band GSM

Quad-band GSM

Dual-band 800/1900 MHz CDMA;

 

Frequency

850/900/1800/1900 MHz

850/900/1800/1900 MHz

800 MHz and 800/1900 MHz with

 

 

 

 

R-UIM support

 

Packet Data

EDGE: E-GPRS Up to 240K bps,

Up to 85.6K bps, coding schemes

Up to 153.6K bps forward and

 

 

coding scheme MCS-9, mobile

CS1 to CS4

reverse

 

 

station Class B, LLC layer, 4 time

 

 

 

 

slots

 

 

 

 

GPRS: Full PBCCH support,

 

 

 

 

coding scheme 1-4, mobile station

 

 

 

 

Class B

 

 

 

Circuit-

Up to 14.4K bps, non-transparent

Up to 14.4K bps transparent and

IS-95A, IS 95B up to 14.4K bps

 

Switched Data

 

non-transparent

forward and reverse

 

Short Message

Text & PDU, Point-to-Point

Text & PDU, Point-to-Point, cell

Text & UCS-2, Point-to-Point, cell

 

Services-SMS

(MO/MT), cell broadcast

broadcast

broadcast

 

Fax

Class 1 Group 3

GSM Class 1 and Class 2 Group 3

Class 2.0 Group 3

 

Voice Features

Half rate (HR), Full rate (FR),

Half rate (HR), Full rate (FR),

Telephony and Dual Tone Multi

 

 

Enhanced full rate (EHR),

Enhanced full rate (EHR), echo

Frequency (DTMF) functionality,

 

 

Adaptive multi rate (AMR), hands

cancellation, noise reduction

AMPS Voice, QCELP (13K), echo

 

 

free echo cancellation, noise

(option), telephony and Dual Tone

cancellation

 

 

reduction

Multi Frequency (DTMF)

 

 

 

 

transmission, emergency calls

 

 

Antenna

RF Antenna: 50 ohm SMA (female

RF Antenna: 50 ohm SMA (female

RF Antenna: 50 ohm SMA (female

 

Connectors

connector)

connector)

connector)

 

SIM Connector

Standard 3V SIM receptacle

Standard 3V SIM receptacle

 

 

Interface

Ethernet Model: RJ-45,

Ethernet Model: RJ-45,

Ethernet Model: RJ-45,

 

Connectors

10BaseT/100BaseTX, 802.3

10BaseT/100BaseTX, 802.3

10BaseT/100BaseTX, 802.3

 

Power

Ethernet Model: 2.5mm miniature

Ethernet Model: 2.5mm miniature

Ethernet Model: 2.5mm miniature

 

Connectors

screw

screw

screw

 

Voice

Ethernet Model: RJ-94-pos

NA

NA

 

Connectors

modjack

 

 

 

Voltage

5V to 32 VDC

5V to 32 VDC

5V to 32 VDC

 

Power (Max.

950mA at 5V

800mA at 5V

840mA at 5V

 

Current Draw)

 

 

 

 

Physical

Ethernet Model:

Ethernet Model:

Ethernet Model:

 

Description

2.8" L x 6.4" W x 1.2" H; 11.5 oz.

2.8" L x 6.4" W x 1.2" H; 11.5 oz.

2.8" L x 6.4" W x 1.2" H; 11.5 oz.

 

 

(7.1 cm x 16.3 cm x 3.0 cm; 326G)

(7.1 cm x 16.3 cm x 3.0 cm; 326G)

(7.1 cm x 16.3 cm x 3.0 cm; 326G)

 

Operating

-30°to +60° C

-20°to +55° C

-20°to +55° C

 

Temperature

 

 

 

 

Storage

-40°to +85° C

-40°to +85° C

-40°to +85° C

 

Temperature

 

 

 

 

Humidity

Relative humidity 20% to 90%

Relative humidity 20% to 90%

Relative humidity 20% to 90%

 

 

condensing

condensing

condensing

 

Certifications

CE Mark, R&TTE

CE Mark, R&TTE

EMC: FCC Part 2, 15, 22, 24; EN

 

 

EMC: FCC Part 2, 15, 22, 24; EN

EMC: FCC Part 2, 15, 22, 24; EN

55022, EN 55024

 

 

55022, EN 55024

55022, EN 55024

Safety: cUL, UL 60950; EN 60950

 

 

Safety: cUL, UL 60950; EN 60950

Safety: cUL, UL 60950; EN 60950

Network: CDG 1 & 2

 

 

Network: PTCRB

Network: PTCRB

 

 

Miscellaneous

AT Command Compatible

AT Command Compatible

AT Command Compatible

 

 

Desktop or panel mounting

Desktop or panel mounting

Desktop or panel mounting

 

 

Carrier approved

Carrier approved

Carrier approved

 

 

Numerous LEDs provide status

Numerous LEDs provide status

Numerous LEDs provide status

 

 

Embedded TCP/IP stack

Embedded TCP/IP stack

Over-the-air activation

 

 

Two year warranty

Two year warranty

Embedded TCP/IP stack

 

 

 

 

Two year warranty

AT Command Information

AT Commands: AT commands for the GPRS, GPRS-F4-IP, CDMA, and EDGE wireless modem are published in separate Reference Guides included on the MultiModem CD and posted on the Multi-Tech web site.

Multi-Tech Systems, Inc. MultiModem Wireless Modem with Ethernet Interface (S000375F)

8

Image 8
Contents MultiModem User Guide CopyrightRecord of Revisions Revision Date Description TrademarksTable of Contents Packet Filters GRE TunnelsDhcp Server ToolsIntroduction Product Description Product and Interface DescriptionsApplication Example Ship Kit Contents Safety Warnings Handling PrecautionsVehicle Safety Ethernet Ports CautionFeatures Edge Modems Gprs Modems Cdma Modems SpecificationsAT Command Information Setup a Wireless Account Connect Antenna, Ethernet, & PowerPhone Numbers for the Wireless Modem Getting StartedOptional Fused DC Power Connection Optional Attach the Modem to a Flat SurfaceModem LEDs Front Panel LEDsEthernet LEDs Set Your PC’s TCP/IP Address for Ethernet Functionality Using AT Commands Prerequisite StepsAT Command for Verifying Signal Strength Exiting Modem ModeSignal Strength Rssi Network Registration VerificationOpen a Web browser Use the Wizard Setup for Quick ConfigurationBenefits of Using the Wizard Setup PPP Configuration PPP AuthenticationAuthentication PasswordSet Time and Date Shutdown CautionImportant Note About Provider Fees Connecting to the InternetConnecting to the Internet Steps Page Using the Web Management Software Navigating the Web Management SoftwareNetworks IP SetupServices Tunnels Logs IP Setup Web Management Software ScreensGeneral Configuration IP ConfigurationAuto Dialout Configuration Syslog ConfigurationGeneral SubmitTime Zone Configuration Daylight ConfigurationDaylight Saving Start Time Daylight Saving End TimeAdd Static Routes Important NoteIP Setup Remote Configuration Remote ConfigurationPPP PPP Configuration NAT ConfigurationIf NAT is enabled If NAT is disabledPPP General Icmp Keep Alive CheckWakeup-on-Call Configuration Caller ID ConfigurationCaller Acknowledgement Configuration PPP Wakeup-on-CallPPP Wakeup-On-Call Examples For Gprs and EDGE, it is *99***1# Set the Time Delay. Use can use the 10 second default PPP Power-On Configuration PPP Modem CommandsPower-On Init String Configuration Example of Useful Gprs AT CommandsNetwork Configuration Networks & ServicesNetworks & Services Network Configuration Networks & Services Service Configuration Service ConfigurationPacket Filter Packet FiltersPacket Filters Packet Filters Packet Filters Dnat Example Packet Filters Dnat ConfigurationDnat Configuration Example Nochange Example AnyExample MeterIP Connection Tracking Icmp ConfigurationPacket Filters Advanced GRE Tunnels GRE Tunnels GRE Tunnel ConfigurationGRE Tunnels GRE Tunnels GRE Routes Configuration GRE Routes ConfigurationDhcp Server Dhcp Server Subnet SettingsSubnet Settings Dhcp Fixed Configuration ToolsDhcp Server Fixed Addresses Tools ToolsTools Service Status Tools Firmware UpgradeFirmware Upgrade Important NotesLoad Configuration Tools Load ConfigurationTools Save Configuration Statistics & Logs Serial Statistics & LogsStatistics & Logs Ethernet Statistics & Logs PPP Statistics & Logs PPP Trace Statistics & Logs SysInfoStatistics & Logs Modem Information Statistics & Logs Dhcp StatStatistics & Logs GRE Statistics Appendix a a Reference Table of Commonly Supported Subnets Appendix a Reference Table of Commonly Supported Subnets Appendix B Wireless Antenna GSM and E-GSM Radio CharacteristicsCdma Radio Characteristics AntennaFused DC Power Cable Dimensions How to Change the FuseAppendix C Firmware Upgrade Using External Tftp Client Obtaining the Latest Firmware VersionMulti-Tech Warranty Statement Multi-Tech Warranty StatementReplacement Parts Repair Procedures for International DistributorsAppendix E Waste Electrical Electronic Equipment Waste Electrical and Electronic Equipment WeeeGeneral Configuration IP Setup Index31, 32