Multi-Tech Systems MT5634ZPW-PCI owner manual S10

Page 49

3 AT Commands, S-Registers and Result Codes

Register

Unit

Range

Default

Description

S6

seconds

2–65*

2*

Sets the time the modem will wait

 

 

 

 

after it goes off-hook before it be-

 

 

 

 

gins to dial the telephone number.

S7

seconds

1–255*

50*

Sets the time the modem will wait

 

 

 

 

for a carrier signal before aborting

 

 

 

 

a call. Also sets the wait for si-

 

 

 

 

lence time for the @ dial modifier.

S8

seconds

0–65

2

Sets the length of a pause caused

 

 

 

 

by a comma character in a dialing

 

 

 

 

command.

S10

100 ms

1–254

20

Sets how long a carrier signal

 

 

 

 

must be lost before the modem

 

 

 

 

disconnects.

S11

1 ms

50–150*

95*

Sets spacing and duration of dial-

 

 

 

 

ing tones.

S28

decimal

0, 1–255

1

0 disables, 1–255 enables V.34

 

 

 

 

modulation.

S30

1 minute

0–255

0

S30 specifies the length of time (in

 

 

 

 

minutes) that the modem waits

 

 

 

 

before disconnecting when no

 

 

 

 

data is sent or received. This

 

 

 

 

function is only applicable to

 

 

 

 

buffer mode. (Also see \T com-

 

 

 

 

mand.)

S35

decimal

0–1

0

0 disables, 1 enables the V.25 data

 

 

 

 

calling tone, which allows remote

 

 

 

 

data/fax/voice discrimination.

S36

decimal

{0,2}, {1,3} N/A

This register specifies the action

 

 

 

 

to take in the event of negotiation

 

 

{4,6}, {5,7}

failure when error control is se-

 

 

 

 

lected. (See S48.)

MT5634ZPW-PCI

49

Image 49
Contents Model Number MT5634ZPW-PCI Record of Revisions Revision Description Contents AT Commands, S-Registers and Result Codes Appendices Page Introduction and Description Congratulations General features include Fax Peripheral Component Interconnect PCI What is in Your Modem Package?Introduction and Description How to Use This ManualWarranty, Service, and Technical Support You type this Typographic ConventionsInstallation What You’ll Need IntroductionSafety Warnings Sound Card Considerations Install the MultiModemZPW-PCI into the Computer Line Phone Line OUT MIC External ConnectionsIs Your MultiModemZPW-PCI Ready for Use? Installing DriversExit the System Properties sheet Verifying ConfigurationHow to Remove Your Old Modem from Windows Operating Your MultiModemZPW-PCI Simple Operations Software ConfigurationSelect Start, Programs, Accessories, HyperTerminal Testing the MultiModemZPW-PCI’s Data FunctionsIf you don’t know the file name Select Start, Programs, Accessories, WordPad Testing the MultiModemZPW-PCI’s FAX FunctionsTesting the MultiModemZPW-PCI’s Voice Function Other Ways to Access Microsoft FaxMultiModemZPW-PCI’s Answering Machine Test MultiModemZPW-PCI’s Speakerphone Test Loopback TestingInstallation MT5634ZPW-PCI AT Commands, S-Registers and Result Codes Configuring Communications Software AT Commands, S-Registers and Result Codes ∗ *70 is only used in the United States Command +++ATCR Escape Sequence AT CommandsEnter Key Detect AT&Ts call card toneCommunication Standard Setting Repeat Last CommandCarrier Control DialDS= n Dial Stored Telephone Number Echo Command Mode CharactersEcho Online Data Characters Hook ControlMonitor Speaker Mode Monitor Speaker VolumeInformation Request Modulation HandshakeResult Codes Enable/Disable Return Online to Data Mode= n Set Register Value Read Register ValueResult Code Selection Modem ResetLong Space Disconnect Auto RetrainData Carrier Detect DCD Control Load Factory Default SettingsData Terminal Ready DTR Control 22bis Guard Tone ControlAsynchronous Communications Mode Communications ModeSelf-Test Commands View Current ConfigurationSelect Stored Configuration for Hard Reset Store Current ConfigurationStore Telephone Number \G n Modem Port Flow Control\Tn Inactivity Timer \Nn Error Correction Mode Selection\Qn Local Flow Control Selection \Vn Protocol Result Code+ES=6 Enable Synchronous Buffered Mode Command %C n Data Compression ControlCommand %T94 Testing External RAM Data Calling ToneRegisters Command %T125 Testing DSP 56K Code Version/ChecksumS10 Register Unit Range Default Description S37 Register Unit Range Default Description S42 Terse Verbose Description Result CodesDelayed MT5634ZPW-PCI Troubleshooting Initial Checklist Troubleshooting Common ProblemsModem Does Not Respond to Commands Troubleshooting Modem Dials But Cannot Make a Connection Troubleshooting Modem Disconnects While Online File Transfer Appears Slower Than It Should Be Modem Cannot Connect When AnsweringData Is Being Lost Fax and Data Software Won’t Run at the Same Time There Are Garbage Characters on the MonitorWarranty, Service and Technical Support Limited Warranty Recording Modem Information Technical SupportMT5634ZPW-PCI Attn Repair ServiceLogging on to the Multi-Tech BBS Multi-Tech BBSIf you know the file name Downloading a FileLeaving a Message Reading a MessageBulletins About the Internet About CompuServeAbout the Multi-Tech Fax-Back Service Appendices MT5634ZPW-PCI Appendices MT5634ZPW-PCI Canadian Limitations Notice Ringer Equivalence Number Compliance with Babt Requirements Figure A-1. Creepage and Clearance Distances European Low Voltage Directive MT5634ZPW-PCI Appendices Compliance with BS6328 Part Compliance with BS6789 .1 and PartEuropean Community Directives CE Register Default Permissible Range Command Default Permissible RangeAustralian and New Zealand Modem Warning Notice New Zealand Telecom Warning Notice Client-to-Server Data Rates Appendix B Technical SpecificationsError Correction Command Buffer Diagnostics Ctrl Code HEX DEC Code HEX DEC Code HEX DEC Code HEX DEC Appendix C Ascii Conversion Chart

MT5634ZPW-PCI specifications

The Multi-Tech Systems MT5634ZPW-PCI is a cutting-edge data communication solution, specifically designed for businesses and professional users requiring reliable connectivity. This PCI modem offers a host of impressive features, technologies, and characteristics that make it a preferred choice for various applications, ranging from internet access to remote station communications.

One of the standout features of the MT5634ZPW-PCI is its support for V.92 technology, enabling faster upload and download speeds compared to traditional modems. With a maximum theoretical throughput of 56 Kbps for downloads, and 48 Kbps for uploads, users can experience high-speed internet access for better efficiency and productivity. This modem also supports V.90 and V.34 protocols, ensuring compatibility with a wide range of existing infrastructure.

Another significant aspect of the MT5634ZPW-PCI is its integrated error correction and data compression technologies, which enhance the quality and speed of data transmission. With its support for MNP2-4 and V.42 error correction, users benefit from reduced data loss and improved communication reliability. Additionally, V.42bis data compression allows for more efficient use of the modem’s bandwidth, enabling users to transmit more data within the same timeframe.

The device is equipped with a PCI interface, ensuring easy installation into desktop systems, while the included drivers provide seamless integration with various operating systems, including Windows and Linux. This versatility makes the MT5634ZPW-PCI suitable for a range of applications, whether in desktops or specialized terminals.

Security is also a focal point with the MT5634ZPW-PCI, as it supports several protocols for secure data communication, including Caller ID, which allows users to screen incoming calls and only accept connections from known numbers.

In terms of design, the modem is compact and efficient, allowing it to fit easily into most standard PC cases. Its durability and reliable performance further increase its appeal for users who require a dependable communication solution.

Overall, the Multi-Tech Systems MT5634ZPW-PCI modem is a powerful, feature-rich device ideal for both professional and personal use. Its combination of high-speed capabilities, advanced technologies, and user-friendly design make it a standout choice for those seeking reliable data communication solutions.