Multi-Tech Systems MT5634ZPW-PCI owner manual New Zealand Telecom Warning Notice

Page 89

Appendices

Failure to set the modem, and any communications software used with the modem, to the values shown above will result in the modem being operated in a non-compliant manner. Consequently, there would be no permit in force for this equipment, and the Telecommunications Act 1991 prescribes a penalty of $12,000 for the connection of non-permitted equipment.

For Voice Modems:

“Distortion may be generated because of low bit rate voice, and reduced voice quality may result.”

WARNING: For safety reasons, only connect AUSTEL permitted or AUSTEL certified equipment.”

Refer to the applicable MultiModemII Owner’s Manual for additional information.

Protection Against Contact with TNV Circuit (Internal PC Cards)

The protective cover is fastened to the modem card by means that will only allow a tool to remove the cover. “Warning: removal of the protective cover will render the AUSTEL permit void.”

New Zealand Telecom Warning Notice

“Use of pulse dialing, when this equipment is connected to the same line as other equipment, may give rise to “bell tinkle” or noise and may also cause a false answer condition. Should such problems occur, the user should NOT contact the Telecom Faults Service.”

“The preferred method of dialing is to use DTMF tones, as this is faster than pulse (decadic) dialing and is readily available on almost all New Zealand telephone exchanges.”

WARNING NOTICE: No ‘111’ or other calls can be made from this device during a mains power failure”.

MT5634ZPW-PCI

89

Image 89
Contents Model Number MT5634ZPW-PCI Record of Revisions Revision Description Contents AT Commands, S-Registers and Result Codes Appendices Page Introduction and Description Congratulations General features include Fax Peripheral Component Interconnect PCI What is in Your Modem Package?Introduction and Description How to Use This ManualWarranty, Service, and Technical Support You type this Typographic ConventionsInstallation What You’ll Need IntroductionSafety Warnings Sound Card Considerations Install the MultiModemZPW-PCI into the Computer Line Phone Line OUT MIC External ConnectionsIs Your MultiModemZPW-PCI Ready for Use? Installing DriversExit the System Properties sheet Verifying ConfigurationHow to Remove Your Old Modem from Windows Operating Your MultiModemZPW-PCI Simple Operations Software ConfigurationSelect Start, Programs, Accessories, HyperTerminal Testing the MultiModemZPW-PCI’s Data FunctionsIf you don’t know the file name Select Start, Programs, Accessories, WordPad Testing the MultiModemZPW-PCI’s FAX FunctionsMultiModemZPW-PCI’s Answering Machine Test Other Ways to Access Microsoft FaxTesting the MultiModemZPW-PCI’s Voice Function MultiModemZPW-PCI’s Speakerphone Test Loopback TestingInstallation MT5634ZPW-PCI AT Commands, S-Registers and Result Codes Configuring Communications Software AT Commands, S-Registers and Result Codes ∗ *70 is only used in the United States Command +++ATCR Escape Sequence AT CommandsEnter Key Detect AT&Ts call card toneCommunication Standard Setting Repeat Last CommandCarrier Control DialDS= n Dial Stored Telephone Number Echo Command Mode CharactersEcho Online Data Characters Hook ControlMonitor Speaker Mode Monitor Speaker VolumeInformation Request Modulation HandshakeResult Codes Enable/Disable Return Online to Data Mode= n Set Register Value Read Register ValueResult Code Selection Modem ResetLong Space Disconnect Auto RetrainData Carrier Detect DCD Control Load Factory Default SettingsData Terminal Ready DTR Control 22bis Guard Tone ControlAsynchronous Communications Mode Communications ModeSelf-Test Commands View Current ConfigurationSelect Stored Configuration for Hard Reset Store Current ConfigurationStore Telephone Number \G n Modem Port Flow Control\Tn Inactivity Timer \Nn Error Correction Mode Selection\Qn Local Flow Control Selection \Vn Protocol Result Code+ES=6 Enable Synchronous Buffered Mode Command %C n Data Compression ControlCommand %T94 Testing External RAM Data Calling ToneRegisters Command %T125 Testing DSP 56K Code Version/ChecksumS10 Register Unit Range Default Description S37 Register Unit Range Default Description S42 Terse Verbose Description Result CodesDelayed MT5634ZPW-PCI Troubleshooting Initial Checklist Troubleshooting Common ProblemsModem Does Not Respond to Commands Troubleshooting Modem Dials But Cannot Make a Connection Troubleshooting Modem Disconnects While Online Data Is Being Lost Modem Cannot Connect When AnsweringFile Transfer Appears Slower Than It Should Be Fax and Data Software Won’t Run at the Same Time There Are Garbage Characters on the MonitorWarranty, Service and Technical Support Limited Warranty Recording Modem Information Technical SupportMT5634ZPW-PCI Attn Repair ServiceLogging on to the Multi-Tech BBS Multi-Tech BBSIf you know the file name Downloading a FileBulletins Reading a MessageLeaving a Message About the Internet About CompuServeAbout the Multi-Tech Fax-Back Service Appendices MT5634ZPW-PCI Appendices MT5634ZPW-PCI Canadian Limitations Notice Ringer Equivalence Number Compliance with Babt Requirements Figure A-1. Creepage and Clearance Distances European Low Voltage Directive MT5634ZPW-PCI Appendices Compliance with BS6328 Part Compliance with BS6789 .1 and PartEuropean Community Directives CE Australian and New Zealand Modem Warning Notice Command Default Permissible RangeRegister Default Permissible Range New Zealand Telecom Warning Notice Client-to-Server Data Rates Appendix B Technical SpecificationsError Correction Command Buffer Diagnostics Ctrl Code HEX DEC Code HEX DEC Code HEX DEC Code HEX DEC Appendix C Ascii Conversion Chart

MT5634ZPW-PCI specifications

The Multi-Tech Systems MT5634ZPW-PCI is a cutting-edge data communication solution, specifically designed for businesses and professional users requiring reliable connectivity. This PCI modem offers a host of impressive features, technologies, and characteristics that make it a preferred choice for various applications, ranging from internet access to remote station communications.

One of the standout features of the MT5634ZPW-PCI is its support for V.92 technology, enabling faster upload and download speeds compared to traditional modems. With a maximum theoretical throughput of 56 Kbps for downloads, and 48 Kbps for uploads, users can experience high-speed internet access for better efficiency and productivity. This modem also supports V.90 and V.34 protocols, ensuring compatibility with a wide range of existing infrastructure.

Another significant aspect of the MT5634ZPW-PCI is its integrated error correction and data compression technologies, which enhance the quality and speed of data transmission. With its support for MNP2-4 and V.42 error correction, users benefit from reduced data loss and improved communication reliability. Additionally, V.42bis data compression allows for more efficient use of the modem’s bandwidth, enabling users to transmit more data within the same timeframe.

The device is equipped with a PCI interface, ensuring easy installation into desktop systems, while the included drivers provide seamless integration with various operating systems, including Windows and Linux. This versatility makes the MT5634ZPW-PCI suitable for a range of applications, whether in desktops or specialized terminals.

Security is also a focal point with the MT5634ZPW-PCI, as it supports several protocols for secure data communication, including Caller ID, which allows users to screen incoming calls and only accept connections from known numbers.

In terms of design, the modem is compact and efficient, allowing it to fit easily into most standard PC cases. Its durability and reliable performance further increase its appeal for users who require a dependable communication solution.

Overall, the Multi-Tech Systems MT5634ZPW-PCI modem is a powerful, feature-rich device ideal for both professional and personal use. Its combination of high-speed capabilities, advanced technologies, and user-friendly design make it a standout choice for those seeking reliable data communication solutions.