2.3 Mounting the SIM100

®

2.3 Mounting the SIM100

Attach the SIM100 securely to the vessel using the included stainless steel mounting screws or other fasteners as shown in Figure 1 below.

Figure 1 – Mounting the SIM100

2.4 Connecting the SIM100

The SIM100 requires two types of electrical connections: 1) the NMEA 2000® connection (refer to Section 2.4.1), and 2) the switch connections, which are described in Section 2.4.2.

2.4.1 NMEA 2000® Connection

The NMEA 2000® connector can be found on the side of the enclosure. The NMEA 2000® connector is a round five pin male connector (see Figure 2). You connect the SIM100 to an NMEA 2000® network using a Maretron NMEA 2000® cable (or compatible cable) by connecting the female end of the cable to the SIM100 (note the key on the male connector and keyway on the female connector). Be sure the cable is connected securely and that the collar on the cable connector is tightened firmly. Connect the other end of the cable (male) to the NMEA 2000® network in the same manner. The SIM100 is designed such that you can plug or unplug it from an NMEA 2000® network while the power to the network is connected or disconnected. Please follow recommended practices for installing NMEA 2000® network products.

Revision 1.0

Page 3

Image 7
Contents Maretron, LLP 9014 N. 23rd Ave #10 RevisionPage Revision Copyright 2008 Maretron, LLP All Rights ReservedRevision Revision HistorySIM100 Users Manual PageTable of Figures Table of ContentsTable of Appendices Page 1 Introduction 1.2 SIM100 Features1.1 Firmware Revision 2.1 Unpacking the Box 2 Installation1.3 SIM100 Accessories 1.4 Quick InstallFigure 1 - Mounting the SIM100 2.4 Connecting the SIM1002.3 Mounting the SIM100 2.4.1 NMEA 2000 ConnectionConnection 2.4.2 Switch ConnectionsFigure 2 - NMEA 2000 Connector Face Views Pin # Signal NameFigure 4 - Switch Without End of Line Resistor Connection Diagram 2.4.2.1 Switch With End of Line ResistorFigure 3 - Switch With End of Line Resistor Connection Diagram 2.4.2.2 Switch Without End of Line Resistor2.5.2 Channel #1 Mode 2.5.3 Channel #2 Mode 2.5.4 Channel #3 Mode 2.5 Configuring the SIM1002.4.3 Checking Connections 2.5.1 Device Instance2.5.9 NMEA 2000 PGN Enable/Disable 3 Maintenance4 Troubleshooting 2.5.8 Advanced Configuration…Page NMEA 2000 Parameter Group Numbers PGNs 5 Technical SpecificationsSpecifications Certificationssupport@maretron.com 6 Technical SupportFigure 5 - Mounting Surface Template 7 Installation TemplateWarranty Return Procedure 8 Maretron 2 Year Limited WarrantyAppendix A - NMEA 2000 Interfacing PGN 127501 - Binary Switch Bank StatusAppendix A - NMEA 2000 Interfacing SIM100 NMEA 2000 Periodic Data Transmitted PGNs