Maretron SIM100 Switch Connections, NMEA 2000 Connector Face Views, Pin # Signal Name, Page

Page 8
Figure 2 – NMEA 2000® Connector Face Views

SIM100 User's Manual

Figure 2 – NMEA 2000® Connector Face Views

2.4.2 Switch Connections

The SIM100 switch connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the four screws at the corners of the unit detaching the splash guard from the unit. On the bottom of the splash guard, you will find a label detailing the wire connection to pin number assignments, which are repeated in the table below.

Pin # Signal Name

1SW1A

2SW1B

3SW2A

4SW2Bl

5SW3Al

6SW3B

7SW4A

8SW4B

9SW5A

10SW5B

11SW6A

12SW6B

Connection

Switch #1 Signal A

Switch #1 Signal B

Switch #2 Signal A

Switch #2 Signal B

Switch #3 Signal A

Switch #3 Signal B

Switch #4 Signal A

Switch #4 Signal B

Switch #5 Signal A

Switch #5 Signal B

Switch #6 Signal A

Switch #6 Signal B

Before attempting to connect the SIM100 to the AC source, determine the type of system you will be monitoring. The SIM100 supports the connection and monitoring of two different system types; 1) switch with end-of-line resistor (Section 2.4.2.1), or 2) switch without end-of-line resistor (Section 2.4.2.2). To connect Maretron SIM100 accessories, please refer to the installation directions that accompany each accessory.

Page 4

Revision 1.0

Image 8
Contents Revision PageRevision Copyright 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10Revision History SIM100 Users ManualPage RevisionTable of Appendices Table of ContentsTable of Figures Page 1.1 Firmware Revision 1.2 SIM100 Features1 Introduction 2 Installation 1.3 SIM100 Accessories1.4 Quick Install 2.1 Unpacking the Box2.4 Connecting the SIM100 2.3 Mounting the SIM1002.4.1 NMEA 2000 Connection Figure 1 - Mounting the SIM1002.4.2 Switch Connections Figure 2 - NMEA 2000 Connector Face ViewsPin # Signal Name Connection2.4.2.1 Switch With End of Line Resistor Figure 3 - Switch With End of Line Resistor Connection Diagram2.4.2.2 Switch Without End of Line Resistor Figure 4 - Switch Without End of Line Resistor Connection Diagram2.5 Configuring the SIM100 2.4.3 Checking Connections2.5.1 Device Instance 2.5.2 Channel #1 Mode 2.5.3 Channel #2 Mode 2.5.4 Channel #3 Mode3 Maintenance 4 Troubleshooting2.5.8 Advanced Configuration… 2.5.9 NMEA 2000 PGN Enable/DisableRevision 5 Technical Specifications SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNs6 Technical Support support@maretron.com7 Installation Template Figure 5 - Mounting Surface Template8 Maretron 2 Year Limited Warranty Warranty Return ProcedurePGN 127501 - Binary Switch Bank Status Appendix A - NMEA 2000 InterfacingSIM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 Interfacing