Congratulations on your purchase of the Maretron Switch Indicator Module. Maretron has designed and built your SIM100 to the highest standards for years of dependable and accurate service.

Maretron’s Switch Indicator Module monitors switch closure devices including, but not limited to, safety equipment (e.g., heat, smoke, carbon monoxide, explosive vapor detectors), security systems (e.g., motion, vibration, glass break, door and port hole magnetic switches), and vessel monitoring equipment (e.g., valve closed/open, high water bilge). The SIM100 continually monitors these switch closure devices and broadcasts information over the NMEA 2000 network about the switch state so the crew can be alerted to potential conditions or problems that warrant further investigation. Advanced features of the SIM100 include the ability to detect whether or not power has been disconnected from the monitored device or if the signal wires have been disconnected due to either corrosion, tampering, or for any other reason (if the monitored device is so equipped). With the SIM100, you can rest assured that critical sensors are receiving power, signal wires are connected, and all the safety, security and vessel functions are under constant supervision.

The Maretron SIM100 is designed to operate within the harsh demands of the marine environment. However, no piece of marine electronic equipment can function properly unless installed, configured, and maintained in the correct manner. Please read carefully and follow these instructions for installation, configuration, and usage of the Maretron SIM100 in order to ensure optimal performance.

1.1 Firmware Revision

This manual corresponds to SIM100 firmware revision 1.0.0.

1.2 SIM100 Features

The Maretron SIM100 has the following features.

NMEA 2000® Interface

Waterproof Connectors

Sealed Waterproof Enclosure

Opto-Isolated from NMEA 2000® Eliminating Potential Ground Loops

Monitors and reports switch status

Can detect and report problems like opens and shorts in switch circuits

Compatible with Maretron-Supplied

oHeat Detectors

oSmoke Detectors

oCarbon Monoxide Detectors

oBilge Water Detectors

Also Compatible With

oMagnetic Switches

oGlass Break Detectors

oDoor, Hatch, and Porthole Magnetic Switches

Revision 1.0

Page 1

Image 5
Contents Page RevisionRevision Copyright 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10SIM100 Users Manual Revision HistoryPage RevisionTable of Appendices Table of ContentsTable of Figures Page 1.1 Firmware Revision 1.2 SIM100 Features1 Introduction 1.3 SIM100 Accessories 2 Installation1.4 Quick Install 2.1 Unpacking the Box2.3 Mounting the SIM100 2.4 Connecting the SIM1002.4.1 NMEA 2000 Connection Figure 1 - Mounting the SIM100Figure 2 - NMEA 2000 Connector Face Views 2.4.2 Switch ConnectionsPin # Signal Name ConnectionFigure 3 - Switch With End of Line Resistor Connection Diagram 2.4.2.1 Switch With End of Line Resistor2.4.2.2 Switch Without End of Line Resistor Figure 4 - Switch Without End of Line Resistor Connection Diagram2.4.3 Checking Connections 2.5 Configuring the SIM1002.5.1 Device Instance 2.5.2 Channel #1 Mode 2.5.3 Channel #2 Mode 2.5.4 Channel #3 Mode4 Troubleshooting 3 Maintenance2.5.8 Advanced Configuration… 2.5.9 NMEA 2000 PGN Enable/DisableRevision Specifications 5 Technical SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNssupport@maretron.com 6 Technical SupportFigure 5 - Mounting Surface Template 7 Installation TemplateWarranty Return Procedure 8 Maretron 2 Year Limited WarrantyAppendix A - NMEA 2000 Interfacing PGN 127501 - Binary Switch Bank StatusSIM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 Interfacing