Maretron SIM100 user manual Appendix A - NMEA 2000 Interfacing, Page A1, Revision

Page 17
Appendix A – NMEA 2000® Interfacing

®

Appendix A – NMEA 2000® Interfacing

SIM100 NMEA 2000® Periodic Data Transmitted PGNs

PGN 127501 – Binary Switch Bank Status

The SIM100 uses this PGN to transmit the state of each of the connected switch inputs

Field 1: Indicator Bank Instance – This field identifies the particular switch bank to which this PGN applies. Please refer to Section 2.5.1 for instructions on how to program the value of this field.

2:Indicator #1 – This field indicates the state of the switch connected to the SW1A and SW1B inputs of the SIM100. The state will be one of the following values:

“Closed” – The monitored switch is closed.

“Open” – The monitored switch is open.

“Error” – There is an open connection between the SIM100 and the monitored switch. This state can occur only when the indicator is configured to use an End of Line Resistor.

“Data Not Available” – The indicator is configured as “Disabled”

3:Indicator #2 – This field indicates the state of the switch connected to the SW2A and SW2B inputs of the SIM100.

4:Indicator #3 – This field indicates the state of the switch connected to the SW3A and SW3B inputs of the SIM100.

5:Indicator #4 – This field indicates the state of the switch connected to the SW4A and SW4B inputs of the SIM100.

6:Indicator #5 – This field indicates the state of the switch connected to the SW5A and SW5B inputs of the SIM100.

7:Indicator #6 – This field indicates the state of the switch connected to the SW6A and SW6B inputs of the SIM100.

Revision 1.0

Appendix A – NMEA 2000 Interfacing

Page A1
Image 17
Contents Page RevisionRevision Copyright 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10SIM100 Users Manual Revision HistoryPage RevisionTable of Appendices Table of ContentsTable of Figures Page 1.1 Firmware Revision 1.2 SIM100 Features1 Introduction 1.3 SIM100 Accessories 2 Installation1.4 Quick Install 2.1 Unpacking the Box2.3 Mounting the SIM100 2.4 Connecting the SIM1002.4.1 NMEA 2000 Connection Figure 1 - Mounting the SIM100Figure 2 - NMEA 2000 Connector Face Views 2.4.2 Switch ConnectionsPin # Signal Name ConnectionFigure 3 - Switch With End of Line Resistor Connection Diagram 2.4.2.1 Switch With End of Line Resistor2.4.2.2 Switch Without End of Line Resistor Figure 4 - Switch Without End of Line Resistor Connection Diagram2.4.3 Checking Connections 2.5 Configuring the SIM1002.5.1 Device Instance 2.5.2 Channel #1 Mode 2.5.3 Channel #2 Mode 2.5.4 Channel #3 Mode4 Troubleshooting 3 Maintenance2.5.8 Advanced Configuration… 2.5.9 NMEA 2000 PGN Enable/DisableRevision Specifications 5 Technical SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNssupport@maretron.com 6 Technical SupportFigure 5 - Mounting Surface Template 7 Installation TemplateWarranty Return Procedure 8 Maretron 2 Year Limited WarrantyAppendix A - NMEA 2000 Interfacing PGN 127501 - Binary Switch Bank StatusSIM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 Interfacing