Maretron TP-EGT-1 Technical Support, Electrical, Mechanical, Environmental, TMP100 Users Manual

Page 14
Electrical

TMP100 User's Manual

128723

Temperature, High Range (Exhaust Gas Temperature)

0.5 times/second

Electrical

Parameter

Value

Operating Voltage

9 to 32 Volts

Power Consumption

50 mA

Load Equivalence Number (LEN)

1

Reverse Battery Protection

Yes

Load Dump Protection

Yes

Comment

DC Voltage

NMEA 2000® Interface

NMEA 2000® Spec. (1LEN = 50 mA) Indefinitely

Energy Rated per SAE J1113

Mechanical

Parameter

Value

Size

3.50” x 4.20” x 2.03”

 

(88.9mm x 106.7mm x 51.6mm)

Weight

13 oz. (368.5 g)

Comment

Including Flanges for Mounting

Environmental

Parameter

IEC 60945 Classification

Degree of Protection

Operating Temperature

Storage Temperature

Relative Humidity

Vibration

Solar Radiation

Corrosion (Salt Mist)

Electromagnetic Emission

Electromagnetic Immunity

Safety Precautions

Value

Exposed

IP64

-25°C to 55°C -40°C to 70°C

93%RH @40° per IEC60945-8.2

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12

Conducted and Radiated Emission per IEC 60945-9

Conducted, Radiated, Supply, and ESD per IEC 60945-10

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12

6 Technical Support

If you require technical support for Maretron products, you can reach us in any of the following ways:

Telephone:

1-866-550-9100

Fax:

1-602-861-1777

E-mail:

support@maretron.com

World Wide Web:

http://www.maretron.com

Mail:

Maretron, LLC

 

Attn: Technical Support

 

9014 N. 23rd Ave Suite 10

 

Phoenix, AZ 85021 USA

Page 10

Revision 1.0

Image 14
Contents Revision Copyright 2008 Maretron, LLP All Rights Reserved RevisionPage Maretron, LLP 9014 N. 23rd Ave #10Revision Revision HistoryPage RevisionPage Table of ContentsTable of Figures Table of Appendices Appendix A - NMEA 2000 Interfacing1.1 Firmware Revision 1.2 TMP100 Features1 Introduction 1.4 Quick Install 2 Installation1.3 TMP100 Accessories 2.1 Unpacking the Box2.4.1 NMEA 2000 Connection 2.4 Connecting the TMP1002.3 Mounting the TMP100 Connection Pin # Signal Name2.4.2 Temperature Probe Connections 2.4.2.1 Exhaust Gas Temperature EGT Probe Figure 3 - Exhaust Gas Temperature Probe Connection Diagram2.5.1 Channel #0 - #1 Source 2.5 Configuring the TMP1002.4.3 Checking Connections 2.5.5.2 Restore Factory Defaults 2.5.5 Advanced Configuration…2.5.5.1 NMEA 2000 PGN Enable/Disable 2.5.2 Channel #2 - #5 Source2.5.5.3 Installation Description… 3 Maintenance4 Troubleshooting SymptomCertifications 5 Technical SpecificationsSpecifications NMEA 2000 Parameter Group Numbers PGNsMechanical 6 Technical SupportElectrical Environmental7 Installation Template Figure 5 - Mounting Surface Template8 Maretron 2 Year Limited Warranty Warranty Return ProcedureAppendix A - NMEA 2000 Interfacing Appendix A - NMEA 2000 InterfacingTMP100 NMEA 2000 Periodic Data Transmitted PGNs Page A1Page A2 PGN 130312 -Temperature