Maretron TP-EGT-1 Mounting the TMP100, Connecting the TMP100, NMEA 2000 Connection, Revision

Page 7
2.3 Mounting the TMP100

®

2.3 Mounting the TMP100

Attach the TMP100 securely to the vessel using the included stainless steel mounting screws or other fasteners as shown in Figure 1 below.

Figure 1 – Mounting the TMP100

2.4 Connecting the TMP100

The TMP100 requires two types of electrical connections: 1) the NMEA 2000® connection (refer to Section 2.4.1), and 2) the temperature probe connections, which are described in Section 2.4.2.

2.4.1 NMEA 2000® Connection

The NMEA 2000® connector can be found on the side of the enclosure. The NMEA 2000® connector is a round five pin male connector (see Figure 2). You connect the TMP100 to an NMEA 2000® network using a Maretron NMEA 2000® cable (or compatible cable) by connecting the female end of the cable to the TMP100 (note the key on the male connector and keyway on the female connector). Be sure the cable is connected securely and that the collar on the cable connector is tightened firmly. Connect the other end of the cable (male) to the NMEA 2000® network in the same manner. The TMP100 is designed such that you can plug or unplug it from an NMEA 2000® network while the power to the network is connected or disconnected. Please follow recommended practices for installing NMEA 2000® network products.

Revision 1.0

Page 3

Image 7
Contents Maretron, LLP 9014 N. 23rd Ave #10 RevisionPage Revision Copyright 2008 Maretron, LLP All Rights ReservedRevision Revision HistoryPage RevisionTable of Figures Table of ContentsPage Appendix A - NMEA 2000 Interfacing Table of Appendices1 Introduction 1.2 TMP100 Features1.1 Firmware Revision 2.1 Unpacking the Box 2 Installation1.3 TMP100 Accessories 1.4 Quick Install2.3 Mounting the TMP100 2.4 Connecting the TMP1002.4.1 NMEA 2000 Connection 2.4.2 Temperature Probe Connections Pin # Signal NameConnection Figure 3 - Exhaust Gas Temperature Probe Connection Diagram 2.4.2.1 Exhaust Gas Temperature EGT Probe2.4.3 Checking Connections 2.5 Configuring the TMP1002.5.1 Channel #0 - #1 Source 2.5.2 Channel #2 - #5 Source 2.5.5 Advanced Configuration…2.5.5.1 NMEA 2000 PGN Enable/Disable 2.5.5.2 Restore Factory DefaultsSymptom 3 Maintenance4 Troubleshooting 2.5.5.3 Installation Description…NMEA 2000 Parameter Group Numbers PGNs 5 Technical SpecificationsSpecifications CertificationsEnvironmental 6 Technical SupportElectrical MechanicalFigure 5 - Mounting Surface Template 7 Installation TemplateWarranty Return Procedure 8 Maretron 2 Year Limited WarrantyPage A1 Appendix A - NMEA 2000 InterfacingTMP100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 InterfacingPGN 130312 -Temperature Page A2