2.4.2 Temperature Probe Connections

TMP100 User's Manual

Figure 2 – NMEA 2000® Connector Face Views

2.4.2 Temperature Probe Connections

The TMP100 temperature probe connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the four screws at the corners of the unit detaching the splash guard from the unit. On the bottom of the splash guard, you will find a label detailing the wire connection to pin number assignments, which are repeated in the table below.

Pin # Signal Name

1T0+

2T0-

3T1+

4T1-

5T2+

6T2-

7T3+

8T3-

9T4+

10T4-

11T5+

12T5-

Connection

Exhaust Gas Temperature Probe 0 (positive terminal) Exhaust Gas Temperature Probe 0 (negative terminal) Exhaust Gas Temperature Probe 1 (positive terminal) Exhaust Gas Temperature Probe 1 (negative terminal) Temperature Probe 2 (positive terminal)

Temperature Probe 2 (negative terminal) Temperature Probe 3 (positive terminal) Temperature Probe 3 (negative terminal) Temperature Probe 4 (positive terminal) Temperature Probe 4 (negative terminal) Temperature Probe 5 (positive terminal) Temperature Probe 5 (negative terminal)

Before attempting to connect the TMP100 to the temperature probes, determine the type of system you will be monitoring. The TMP100 supports the connection and monitoring of two different system types; 1) Exhaust Gas Temperature probes (Section 2.4.2.1), or 2) thermistor type probes (ring/under bolt probes, immersion probes, and ambient air probes; please see Section 2.4.2.2).

Page 4

Revision 1.0

Image 8
Contents Revision PageRevision Copyright 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10Revision History PageRevision RevisionPage Table of ContentsTable of Figures Table of Appendices Appendix A - NMEA 2000 Interfacing1.1 Firmware Revision 1.2 TMP100 Features1 Introduction 2 Installation 1.3 TMP100 Accessories1.4 Quick Install 2.1 Unpacking the Box2.4.1 NMEA 2000 Connection 2.4 Connecting the TMP1002.3 Mounting the TMP100 Connection Pin # Signal Name2.4.2 Temperature Probe Connections 2.4.2.1 Exhaust Gas Temperature EGT Probe Figure 3 - Exhaust Gas Temperature Probe Connection Diagram2.5.1 Channel #0 - #1 Source 2.5 Configuring the TMP1002.4.3 Checking Connections 2.5.5 Advanced Configuration… 2.5.5.1 NMEA 2000 PGN Enable/Disable2.5.5.2 Restore Factory Defaults 2.5.2 Channel #2 - #5 Source3 Maintenance 4 Troubleshooting2.5.5.3 Installation Description… Symptom5 Technical Specifications SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNs6 Technical Support ElectricalMechanical Environmental7 Installation Template Figure 5 - Mounting Surface Template8 Maretron 2 Year Limited Warranty Warranty Return ProcedureAppendix A - NMEA 2000 Interfacing TMP100 NMEA 2000 Periodic Data Transmitted PGNsAppendix A - NMEA 2000 Interfacing Page A1Page A2 PGN 130312 -Temperature