2.5.2 Channel #2 - #5 Source

®

Temperature, Inside Temperature, Engine Room Temperature, Main Cabin Temperature, Live Well Temperature, Bait Well Temperature, Refrigeration Temperature, Heating System Temperature, Freezer Temperature, Exhaust Gas Temperature, and User Defined Temperature #129-#144.. You may also disable the channel by programming the “Disabled” value into this field.

2.5.2 Channel #2 - #5 Source

You must configure the TMP100 as to what type of temperature measurement it is transmitting. Possible values for channels 2, 3, 4, and 5 include Sea Temperature, Outside Temperature, Inside Temperature, Engine Room Temperature, Main Cabin Temperature, Live Well Temperature, Bait Well Temperature, Refrigeration Temperature, Heating System Temperature, Freezer Temperature, and User Defined Temperature #129-#144. (please note that Exhaust Gas Temperature is not available on channels 2, 3, 4, and 5). You may also disable the channel by programming the “Disabled” value into this field.

2.5.3 Channel #0 - #5 Instance

Each temperature measurement with a given source must have a unique instance number associated with it. This enables monitoring software and displays to distinguish different temperature measurements from one another. For example, if a channel is programmed to transmit a source type of Exhaust Gas Temperature and the instance for that channel is set to a value of 0, then no other Exhaust Gas Temperature measurement on the network may use an instance number of 0.

2.5.4 Channel #0 - #5 Label

Each channel that can be monitored by the TMP100 may be programmed with a text label that will be displayed in monitoring software and displays that recognize device labels, such as the Maretron N2KView Vessel Monitoring System and the Maretron DSM250 display. The label will let you assign an easy-to-remember text label (example: “Forward Bilge Pump”) to make it easy for you to identify the device as you are configuring the monitoring software or display, as well as when alerts are generated.

2.5.5 Advanced Configuration…

Certain parameters do not normally need to be set in order for normal operation, but are included in an advanced configuration section for use in special situations.

2.5.5.1 NMEA 2000® PGN Enable/Disable

The TMP100 is capable of transmitting NMEA 2000® messages (or PGNs) associated with monitored switch circuits. You may individually enable or disable each of these messages. You may also change the rate of transmission of each of these messages if desired.

2.5.5.2 Restore Factory Defaults

Selecting this configuration option causes all stored parameters in the TMP100 to be reset to the values they contained when the unit was manufactured.

Revision 1.0

Page 7

Image 11
Contents Maretron, LLP 9014 N. 23rd Ave #10 RevisionPage Revision Copyright 2008 Maretron, LLP All Rights ReservedRevision Revision HistoryPage RevisionPage Table of ContentsTable of Figures Appendix A - NMEA 2000 Interfacing Table of Appendices1.1 Firmware Revision 1.2 TMP100 Features1 Introduction 2.1 Unpacking the Box 2 Installation1.3 TMP100 Accessories 1.4 Quick Install2.4.1 NMEA 2000 Connection 2.4 Connecting the TMP1002.3 Mounting the TMP100 Connection Pin # Signal Name2.4.2 Temperature Probe Connections Figure 3 - Exhaust Gas Temperature Probe Connection Diagram 2.4.2.1 Exhaust Gas Temperature EGT Probe2.5.1 Channel #0 - #1 Source 2.5 Configuring the TMP1002.4.3 Checking Connections 2.5.2 Channel #2 - #5 Source 2.5.5 Advanced Configuration…2.5.5.1 NMEA 2000 PGN Enable/Disable 2.5.5.2 Restore Factory DefaultsSymptom 3 Maintenance4 Troubleshooting 2.5.5.3 Installation Description…NMEA 2000 Parameter Group Numbers PGNs 5 Technical SpecificationsSpecifications CertificationsEnvironmental 6 Technical SupportElectrical MechanicalFigure 5 - Mounting Surface Template 7 Installation TemplateWarranty Return Procedure 8 Maretron 2 Year Limited WarrantyPage A1 Appendix A - NMEA 2000 InterfacingTMP100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 InterfacingPGN 130312 -Temperature Page A2