Maretron TP-EGT-1 Technical Specifications, Certifications, Revision, Page, Parameter, Value

Page 13
5 Technical Specifications

®

5 Technical Specifications

As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretron products are designed to be accurate and reliable; however, they should be used only as aids to navigation and not as a replacement for traditional navigation aids and techniques.

Specifications

Parameter

Value

Measurement Range – Thermistor

-20°C to 80°C

 

(-4°F to 176°F)

Measurement Accuracy – Thermistor

± 2°C

 

(± 3.6°F)

Measurement Range – Thermocouple

+0°C to 700°C

 

(32°F to 1292°F)

Measurement Accuracy –

± 2°C

Thermocouple

(± 3.6°F)

Comment With supplied thermistor probe

With supplied thermistor probe

With supplied thermocouple probe

With supplied thermocouple probe

Certifications

Parameter

NMEA 2000® Standard

Maritime Navigation and Radiocommunication Equipment & Systems

Maritime Navigation and Radiocommunication Equipment & Systems

FCC and CE Mark

Comment

Level A

IEC 61162-3

IEC 60945

Electromagnetic Compatibility

NMEA 2000® Parameter Group Numbers (PGNs)

 

Description

PGN #
PGN Name
Default Rate

 

Periodic Data PGNs

130310

Environmental Parameters (not

2 times/second

 

 

 

recommended for new designs; included for

 

 

 

 

backward compatibility)

 

 

 

130311

Environmental Parameters (not

2 times/second

 

 

 

recommended for new designs; included for

 

 

 

 

backward compatibility)

 

 

 

130312

Temperature

0.5 times/second

 

 

 

Sources:

 

 

 

 

Sea Temperature

 

 

 

 

Outside Temperature

 

 

 

 

Inside Temperature

 

 

 

 

Engine Room Temperature

 

 

 

 

Main Cabin Temperature

 

 

 

 

Live Well Temperature

 

 

 

 

Bait Well Temperature

 

 

 

 

Refrigeration Temperature

 

 

 

 

Heating System Temperature

 

 

 

 

Freezer Temperature

 

 

Response to Requested

126464

PGN List (Transmit and Receive)

N/A

 

PGNs

126996

Product Information

N/A

 

 

126998

Configuration Information

N/A

 

Protocol PGNs

059392

ISO Acknowledge

N/A

 

 

059904

ISO Request

N/A

 

 

060928

ISO Address Claim

N/A

 

 

065240

ISO Address Command

N/A

 

 

126208

NMEA

N/A

 

Maretron Proprietary PGNs

128720

Configuration

N/A

 

 

 

 

 

 

Revision 1.0

 

 

Page 9

Image 13
Contents Page RevisionRevision Copyright 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10Page Revision HistoryRevision RevisionTable of Figures Table of ContentsPage Appendix A - NMEA 2000 Interfacing Table of Appendices1 Introduction 1.2 TMP100 Features1.1 Firmware Revision 1.3 TMP100 Accessories 2 Installation1.4 Quick Install 2.1 Unpacking the Box2.3 Mounting the TMP100 2.4 Connecting the TMP1002.4.1 NMEA 2000 Connection 2.4.2 Temperature Probe Connections Pin # Signal NameConnection Figure 3 - Exhaust Gas Temperature Probe Connection Diagram 2.4.2.1 Exhaust Gas Temperature EGT Probe2.4.3 Checking Connections 2.5 Configuring the TMP1002.5.1 Channel #0 - #1 Source 2.5.5.1 NMEA 2000 PGN Enable/Disable 2.5.5 Advanced Configuration…2.5.5.2 Restore Factory Defaults 2.5.2 Channel #2 - #5 Source4 Troubleshooting 3 Maintenance2.5.5.3 Installation Description… SymptomSpecifications 5 Technical SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNsElectrical 6 Technical SupportMechanical EnvironmentalFigure 5 - Mounting Surface Template 7 Installation TemplateWarranty Return Procedure 8 Maretron 2 Year Limited WarrantyTMP100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 InterfacingAppendix A - NMEA 2000 Interfacing Page A1PGN 130312 -Temperature Page A2