Lucent Technologies Cajun M770 manual Cajun M400 Manager User’s Guide

Page 68

PSU Enrollment Traps

The trap reports the insertion of a PSU into the

 

device.

 

 

PSU Fault Clear Traps

The trap reports that the PSU failure was corrected.

 

 

PSU Fault Traps

The trap reports the failure of a PSU.

 

 

STA Version

The trap reports that the software on the module is

Inconsistency Traps

outdated and does not support STA.

 

 

Temperature Exceed

The trap reports that the temperature exceed

Clear Traps

condition was corrected.

 

 

Temperature Exceed

Notifies the management station of the internal

Traps

board/enclosure temperature fluctuations. It is

 

generated when the temperature exceeds the

 

hardware defined threshold on the module.

 

 

Version Inconsistency

The trap reports that the software on the module is

Traps

outdated and does not support the full functionality

 

available from the device.

 

 

VIDP Version

The trap reports that the software on the module is

Inconsistency Traps

outdated and does not support VIDP.

 

 

78

Cajun M400 Manager User’s Guide

Image 68
Contents Cajun M770 Manager Page Contents Cajun M770 Manager User’s Guide Cajun M770 Manager User’s Guide Iii Cajun M770 Manager User’s Guide List of Figures Chassis View ToolbarList of Figures Cajun M770 Manager User’s Guide List of Tables Table A.4List of Tables Viii Cajun M770 Manager User’s Guide Welcome to Cajun M770 Management Purpose of this ManualWho Should Use This Manual Organization of this ManualStarting Cajun M770 Management If you are using OpenView Solaris or Hpux or NT-OV Using Chassis View Launching Module ManagersUsing the Toolbar Buttons Selecting ElementsUsing Configuration Windows Help ContentsAgent Configuration General Agent Installation and ConfigurationVerifying Agent Installation Downloading New Agent SoftwareDesignating Managers Viewing the Managers TableAdding Managers to the Managers Table Removing Managers from the Managers TableUpdating the Managers Table Device Configuration Viewing Device Information Device Information Dialog BoxViewing Hardware Configuration Hub Hardware WindowViewing Module Configuration Module Configuration WindowViewing Port Configuration Port Configuration Dialog BoxEnabling Ports Disabling PortsViewing Domain Resource Unit Information DRUs Information WindowViewing ATM Clock Synchronization Configuration Clock Synchronization Dialog BoxDevice Configuration Resetting Elements Resetting the DeviceResetting the Agent Resetting the SwitchFault Management Configuring TrapsViewing Traps Assigning Severity Degrees Unix and NT-OV OnlyEditing Severity Degrees Editing Severity Degrees System-WideFault Management Performance Monitoring Viewing Ethernet Port Counters Ethernet Port Counters WindowViewing Ethernet Port Error Counters Port Error Counters WindowPerformance Monitoring Cajun M770 Manager User’s Guide Port Mirroring Accessing Port Mirroring Port Mirroring Dialog BoxEnabling Port Mirroring Disabling Port MirroringChapter Port Mirroring Cajun M770 Manager User’s Guide Port Redundancy Viewing Port Redundancy InformationDeleting a Port Redundancy Adding a Port RedundancyEditing a Port Redundancy Switch Connected Addresses Switch Connected Addresses for Device WindowSorting the List of Stations Saving the List of StationsVLANs Creating and Editing VLANsAccessing the Vlan List Editing Vlan Names and NumbersEditing Vlan Member Ports Allowing Inter-VLAN Communication Configuration Cajun M770 Management MenusPerformance Help Cajun M770 Manager User’s Guide Configuration Fields 10 of The Reference GuideDisable, use Internal Clock Clock E1Framed E1Unframed36 of The Reference Guide FDX+ISL Algorithm STA on page 27 of The Reference Guide Cajun M400 Manager User’s Guide Algorithm STA on page 27 of The Reference Guide Disabled Time to Restore field Counter Fields Cajun M400 Manager User’s Guide Trap Fields Cajun M400 Manager User’s Guide Accessing IndexCajun M770 Manager User’s Guide Unix Cajun M770 Manager User’s Guide