Installation

2.0INSTALLATION

This section provides instructions for installing, mounting and connecting power and other cables to the OpenComms EM.

2.1Installation Considerations

The OpenComms EM must be installed indoors where electrical service is available. The unit should be placed where it can be easily accessed for connecting the unit to a modem, a computer or a network hub and, if used, serial devices.

The unit may either be mounted on a wall or be placed on a surface, depending on the user’s applica- tion and the location of equipment to be connected and monitored. Consider the length of the sensor cable and the distance to the monitored area when deciding where to place the OpenComms EM, whether you use the 1-ft. (0.3m) cable provided with the unit or the optional 15-ft. (4.6m) cable that may be purchased separately.

2.1.1Unpacking and Preliminary Inspection

Before unpacking the OpenComms EM, inspect the shipping carton for damage or signs of mis- handling, such as gashes or holes in the carton or severely flattened corners.

Open the shipping carton carefully. Use care to avoid puncturing the container with sharp objects that might damage the contents.

Inspect the OpenComms EM and all included components for damage. See Table 3 for a list of items that should be included with each model.

If any damage from shipping or mishandling is observed, immediately file a damage claim with the shipping agency and forward a copy to:

Liebert Corporation

Attn: Traffic Department

1050 Dearborn Drive

P.O. Box 29186

Columbus, OH 43229

Table 3

Standard and optional components shipped with OpenComms EM

 

 

 

 

 

 

 

 

 

 

 

 

 

Kit Part Number

 

STANDARD COMPONENTS (Shipped With Kits)

 

 

 

 

 

TMNET

THCMNET

TMPDUNET

THCMPDUNET

vEM-14

 

 

 

 

 

 

• EM Controller - 2 sensor ports

 

 

 

 

 

 

• EM PDU Controller - 2 sensor ports, 2 serial ports

 

 

 

 

 

 

vEM-14 Controller - 4 sensor ports, 2 serial ports

 

 

 

 

 

 

• CD with software and user manual

 

 

 

 

 

 

• Power supply

 

 

 

 

 

 

Quick-start guide

 

 

 

 

 

 

• Temperature sensor, 1 ft. (0.3m)

 

 

 

 

 

 

• Temperature & humidity combination sensor,

1 ft. (0.3m)

 

 

 

 

 

 

 

 

 

 

 

Built-in temperature and humidity sensor

 

 

 

 

 

 

• Serial cable for MP Advanced Power Strips,

5 ft. (1.5m)

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONAL COMPONENTS (May be Purchased Separately)

 

 

 

 

 

 

 

 

• Contact closure cable, 15 or 100 ft. (4.6 or 30.5m)

• Humidity sensor, 15 or 60 ft. (4.6 or 18.3m)

 

 

 

 

• Water detection sensor, 15 or 60 ft. (4.6 or 18.3m)

• Temperature sensor, 15 or 60 ft. (4.6 or 18.3m)

 

 

 

 

• Serial cable for MP Advanced Power Strips,

• Temperature & humidity combination sensor,

 

10 ft. (3m)

15 or 60 ft. (4.6 or 18.3m)

 

 

 

 

 

 

 

 

 

5

Image 11
Contents Liebert OpenComms EM Page Table of Contents Pinout Guides Getting Started with the WEB InterfaceFigures Page Introduction Overview Dimensions and Mounting Overview EM & EM PDU ControllersDimensions and Mounting Overview vEM-14 Controllers Power and port indicators VEM-14see TableDescription of indicators and connectors Connectors on Back of UnitIndicators summary IndicatorsStandard and optional components shipped with OpenComms EM Installation ConsiderationsInstallation Unpacking and Preliminary Inspection44.5mm Horizontal mounting Vertical mounting Decide on Placement of the OpenComms EMMounting the Unit on a Wall EM / EM PDU Controllers Rack Mounting Mounting the Unit on a Wall or in a Rack vEM-14 ControllersWall Mounting Make Connections Select a Method Consult Your Network AdministratorUse IPSET.exe to Assign an IP Address Assign AN IP AddressUse Dhcp to Assign an IP Address Use ARP to Assign an IP AddressAddress bar Tabs Device Identification Main display Links Main Parts of the Web InterfaceWEB Interface Overview Color coding used in Web interface TabsColor-Coded Status Summary of tab functionsDry-Contact Sensor Thresholds Temperature/Humidity Sensor ThresholdsExamples of sensor limits temperature and humidity sensors Thresholds in the Web InterfaceAmps Name Current Value Color MP Advanced Power Strip ThresholdsExamples of sensor limits MP Advanced power strip sensors Buttons in the Web interface Sensor Names and StatusButtons Sensor information name and statusGetting Started with the WEB Interface Address bar Login window User NamePassword Open the Web Interface and LogExit the Web Interface Update the InformationView Summary Data Types of InformationSensors Window Configure SensorsUse these text boxes Create or Change Sensor NamesSensors tab Names Names for sensors On Sensor 1 port On Sensor 2 portView Sensor Graphs Sensor graph humidity sensor example Zoom in Feature Humidity sensor exampleControl Individual Receptacles Power Window EM PDU & vEM-14 ControllersControl Receptacles Control All Receptacles With One ButtonLinked receptacles Port On, Off, Reboot buttonsPower strip port Receptacle to be linked Link the Controls of Two ReceptaclesRefresh Critical & Warning limits Rearm Graph see Section Configure ThresholdsPower tab Links to set thresholds Select a power strip Zoom in Feature Temperature sensor example View Power Strip GraphsCreate or Change Port Names Power tab Port namesAlerts Window Mail SetupModem Setup Snmp Trap Alerts Setup Security Window Security tab User drop-down list Enter & confirm passwordCreate a New User Account Administrators Only Modify an Existing Account Administrators Only Security tab User drop-down list Delete button Change Password Users with Read/Write accessDelete a User Account Administrators Only Security tab Enter & confirm passwordSys Info tab Default gatewaySys Info Window Network ConnectivitySnmp Information Data Presentation Serial Ports Pinout Guides Modem Setup and Pinout GuideContact Closure Cable Pinout Guide Serial Cable Pinout Guide EM PDU & vEM-14 ControllersDownloading Firmware Updates OpenComms EM specifications SpecificationsPage That Ne tIti Ti n

EM specifications

The Liebert EM is a state-of-the-art, modular and scalable cooling solution designed to meet the needs of today's data centers and IT environments. This innovative unit offers unmatched precision and flexibility, making it ideal for facilities that require meticulous temperature control and energy efficiency.

One of the main features of the Liebert EM is its modular design, allowing for easy expansion and customization based on the specific requirements of a facility. This scalability ensures that organizations can efficiently adapt to changing cooling demands without the need for significant infrastructure changes. The system can be configured in various capacities, making it suitable for spaces of different sizes and cooling needs.

Incorporating advanced technologies, the Liebert EM utilizes inverter-driven compressors, allowing for variable refrigeration capacity. This feature optimizes energy consumption, reducing operational costs while maintaining precise temperature control. The unit is designed with built-in smart controls that enable real-time monitoring and adjustments, ensuring enhanced performance and efficiency across the entire cooling system.

The Liebert EM also comes equipped with EC (Electronically Commutated) fans, which contribute to its energy efficiency by adjusting their speed according to the cooling load. This not only ensures adequate airflow but also minimizes energy waste, leading to lower overall operating costs.

Furthermore, the system features intelligent connectivity options that facilitate integration with existing building management systems. This capability allows for centralized monitoring and control, empowering facility managers to maintain optimal conditions and respond quickly to any fluctuations in temperature or humidity.

Safety and reliability are also paramount in the design of the Liebert EM. The unit includes comprehensive backup systems and redundancy features to ensure continuous operation even in the event of a component failure. This reliability is crucial for critical applications where downtime can result in significant losses.

In summary, the Liebert EM stands out as a versatile and high-performance cooling solution, equipped with advanced technologies that offer scalability, energy efficiency, and precise temperature control. Its modular design, coupled with intelligent control options, makes it an essential component for modern data centers looking to optimize their cooling infrastructure while ensuring reliability and reducing operational costs.