Liebert EM manual Modify an Existing Account Administrators Only

Page 38

Getting Started With the Web Interface

5.6.3Modify an Existing Account (Administrators Only)

Users with administrative privileges may change all options on all users’ accounts, including their own. Users without administrative access are prevented from changing anything except their own password; for details, see 5.6.4 - Change Password (Users with Read/Write access).

To change a user account, log in as an administrator (see 5.1 - Open the Web Interface and Log In) and:

Click on the Security tab to display the Security window, as shown below.

Security tab

User drop-down list

User box: enter name

Enter & confirm password

Access privileges

Inactivity timeout (automatic logoff)

Choose the user name you wish to change from the User drop-down list.

You may not change a user name for an existing account. Instead, delete the existing account, as described in 5.6.5 - Delete a User Account (Administrators Only), and then add a user with the new name (see 5.6.2 - Create a New User Account (Administrators Only)).

Enter a password for this user in the Password box. The password is case-sensitive and must be alphanumeric (spaces are allowed). Verify the password by entering it again in the Confirm Pass- word box.

Specify the type of access privileges for this user by placing a check mark in the appropriate Access box:

Read permits viewing only; users cannot make any changes, except to their own passwords.

Write (includes Read access) allows access to all functions except other users’ accounts; users can view data, change configuration settings and change their own passwords.

Administration (includes Read & Write access) provides full access to all functions, includ- ing creating and modifying other user accounts.

Specify whether the Web interface will log off automatically after the computer is idle for a speci- fied time in the Inactivity Timeout drop-down list. The choices are Never or 1, 2, 5, 15 or 60 min- utes. This setting is applied to all users.

Click Apply to make these changes effective. (To cancel the changes, click Reset.)

32

Image 38
Contents Liebert OpenComms EM Page Table of Contents Getting Started with the WEB Interface Pinout GuidesFigures Page Introduction Power and port indicators VEM-14see Table Dimensions and Mounting Overview EM & EM PDU ControllersDimensions and Mounting Overview vEM-14 Controllers OverviewConnectors on Back of Unit Description of indicators and connectorsIndicators Indicators summaryUnpacking and Preliminary Inspection Installation ConsiderationsInstallation Standard and optional components shipped with OpenComms EM44.5mm Horizontal mounting Vertical mounting Decide on Placement of the OpenComms EMMounting the Unit on a Wall EM / EM PDU Controllers Rack Mounting Mounting the Unit on a Wall or in a Rack vEM-14 ControllersWall Mounting Make Connections Assign AN IP Address Consult Your Network AdministratorUse IPSET.exe to Assign an IP Address Select a MethodUse ARP to Assign an IP Address Use Dhcp to Assign an IP AddressAddress bar Tabs Device Identification Main display Links Main Parts of the Web InterfaceWEB Interface Overview Summary of tab functions TabsColor-Coded Status Color coding used in Web interfaceThresholds in the Web Interface Temperature/Humidity Sensor ThresholdsExamples of sensor limits temperature and humidity sensors Dry-Contact Sensor ThresholdsAmps Name Current Value Color MP Advanced Power Strip ThresholdsExamples of sensor limits MP Advanced power strip sensors Sensor information name and status Sensor Names and StatusButtons Buttons in the Web interfaceOpen the Web Interface and Log Address bar Login window User NamePassword Getting Started with the WEB InterfaceTypes of Information Update the InformationView Summary Data Exit the Web InterfaceConfigure Sensors Sensors WindowOn Sensor 1 port On Sensor 2 port Create or Change Sensor NamesSensors tab Names Names for sensors Use these text boxesView Sensor Graphs Zoom in Feature Humidity sensor example Sensor graph humidity sensor exampleControl All Receptacles With One Button Power Window EM PDU & vEM-14 ControllersControl Receptacles Control Individual ReceptaclesLink the Controls of Two Receptacles On, Off, Reboot buttonsPower strip port Receptacle to be linked Linked receptacles PortRefresh Critical & Warning limits Rearm Graph see Section Configure ThresholdsPower tab Links to set thresholds Select a power strip View Power Strip Graphs Zoom in Feature Temperature sensor examplePower tab Port names Create or Change Port NamesMail Setup Alerts WindowModem Setup Snmp Trap Alerts Setup Security tab User drop-down list Enter & confirm password Security WindowCreate a New User Account Administrators Only Modify an Existing Account Administrators Only Security tab Enter & confirm password Change Password Users with Read/Write accessDelete a User Account Administrators Only Security tab User drop-down list Delete buttonNetwork Connectivity Default gatewaySys Info Window Sys Info tabSnmp Information Data Presentation Serial Ports Serial Cable Pinout Guide EM PDU & vEM-14 Controllers Modem Setup and Pinout GuideContact Closure Cable Pinout Guide Pinout GuidesDownloading Firmware Updates Specifications OpenComms EM specificationsPage Ti n Ne tIti That

EM specifications

The Liebert EM is a state-of-the-art, modular and scalable cooling solution designed to meet the needs of today's data centers and IT environments. This innovative unit offers unmatched precision and flexibility, making it ideal for facilities that require meticulous temperature control and energy efficiency.

One of the main features of the Liebert EM is its modular design, allowing for easy expansion and customization based on the specific requirements of a facility. This scalability ensures that organizations can efficiently adapt to changing cooling demands without the need for significant infrastructure changes. The system can be configured in various capacities, making it suitable for spaces of different sizes and cooling needs.

Incorporating advanced technologies, the Liebert EM utilizes inverter-driven compressors, allowing for variable refrigeration capacity. This feature optimizes energy consumption, reducing operational costs while maintaining precise temperature control. The unit is designed with built-in smart controls that enable real-time monitoring and adjustments, ensuring enhanced performance and efficiency across the entire cooling system.

The Liebert EM also comes equipped with EC (Electronically Commutated) fans, which contribute to its energy efficiency by adjusting their speed according to the cooling load. This not only ensures adequate airflow but also minimizes energy waste, leading to lower overall operating costs.

Furthermore, the system features intelligent connectivity options that facilitate integration with existing building management systems. This capability allows for centralized monitoring and control, empowering facility managers to maintain optimal conditions and respond quickly to any fluctuations in temperature or humidity.

Safety and reliability are also paramount in the design of the Liebert EM. The unit includes comprehensive backup systems and redundancy features to ensure continuous operation even in the event of a component failure. This reliability is crucial for critical applications where downtime can result in significant losses.

In summary, the Liebert EM stands out as a versatile and high-performance cooling solution, equipped with advanced technologies that offer scalability, energy efficiency, and precise temperature control. Its modular design, coupled with intelligent control options, makes it an essential component for modern data centers looking to optimize their cooling infrastructure while ensuring reliability and reducing operational costs.