Liebert EM Change Password Users with Read/Write access, Security tab Enter & confirm password

Page 39

Getting Started With the Web Interface

5.6.4Change Password (Users with Read/Write access)

Users with Read or Read & Write access may change their password but no other user account infor- mation for their own accounts or those of other users.

To change your own password, log in (see 5.1 - Open the Web Interface and Log In) and:

Click on the Security tab to display the Security window, as shown below.

Security tab

Enter & confirm password

Enter a password for this user in the Password box. The password is case-sensitive and must be alphanumeric (spaces are allowed).

Verify the password by entering it again in the Confirm Password box.

Click Apply to make these changes effective. (To cancel the changes, click Reset.)

5.6.5Delete a User Account (Administrators Only)

To delete a user account, log in as an administrator (see 5.1 - Open the Web Interface and Log In) and:

Click on the Security tab to display the Security window, as shown below.

Security tab

User drop-down list

Delete button

Choose the user name you wish to delete from the User drop-down list.

Click the Delete button to remove the selected user account. A confirmation message asks whether to proceed with the deletion. Click OK.

Click Apply to make these changes effective. (To cancel the changes, click Reset.)

33

Image 39
Contents Liebert OpenComms EM Page Table of Contents Pinout Guides Getting Started with the WEB InterfaceFigures Page Introduction Overview Dimensions and Mounting Overview EM & EM PDU ControllersDimensions and Mounting Overview vEM-14 Controllers Power and port indicators VEM-14see TableDescription of indicators and connectors Connectors on Back of UnitIndicators summary IndicatorsStandard and optional components shipped with OpenComms EM Installation ConsiderationsInstallation Unpacking and Preliminary InspectionDecide on Placement of the OpenComms EM Mounting the Unit on a Wall EM / EM PDU Controllers44.5mm Horizontal mounting Vertical mounting Mounting the Unit on a Wall or in a Rack vEM-14 Controllers Wall MountingRack Mounting Make Connections Select a Method Consult Your Network AdministratorUse IPSET.exe to Assign an IP Address Assign AN IP AddressUse Dhcp to Assign an IP Address Use ARP to Assign an IP AddressMain Parts of the Web Interface WEB Interface OverviewAddress bar Tabs Device Identification Main display Links Color coding used in Web interface TabsColor-Coded Status Summary of tab functionsDry-Contact Sensor Thresholds Temperature/Humidity Sensor ThresholdsExamples of sensor limits temperature and humidity sensors Thresholds in the Web InterfaceMP Advanced Power Strip Thresholds Examples of sensor limits MP Advanced power strip sensorsAmps Name Current Value Color Buttons in the Web interface Sensor Names and StatusButtons Sensor information name and statusGetting Started with the WEB Interface Address bar Login window User NamePassword Open the Web Interface and LogExit the Web Interface Update the InformationView Summary Data Types of InformationSensors Window Configure SensorsUse these text boxes Create or Change Sensor NamesSensors tab Names Names for sensors On Sensor 1 port On Sensor 2 portView Sensor Graphs Sensor graph humidity sensor example Zoom in Feature Humidity sensor exampleControl Individual Receptacles Power Window EM PDU & vEM-14 ControllersControl Receptacles Control All Receptacles With One ButtonLinked receptacles Port On, Off, Reboot buttonsPower strip port Receptacle to be linked Link the Controls of Two ReceptaclesConfigure Thresholds Power tab Links to set thresholds Select a power stripRefresh Critical & Warning limits Rearm Graph see Section Zoom in Feature Temperature sensor example View Power Strip GraphsCreate or Change Port Names Power tab Port namesAlerts Window Mail SetupModem Setup Snmp Trap Alerts Setup Security Window Security tab User drop-down list Enter & confirm passwordCreate a New User Account Administrators Only Modify an Existing Account Administrators Only Security tab User drop-down list Delete button Change Password Users with Read/Write accessDelete a User Account Administrators Only Security tab Enter & confirm passwordSys Info tab Default gatewaySys Info Window Network ConnectivitySnmp Information Data Presentation Serial Ports Pinout Guides Modem Setup and Pinout GuideContact Closure Cable Pinout Guide Serial Cable Pinout Guide EM PDU & vEM-14 ControllersDownloading Firmware Updates OpenComms EM specifications SpecificationsPage That Ne tIti Ti n

EM specifications

The Liebert EM is a state-of-the-art, modular and scalable cooling solution designed to meet the needs of today's data centers and IT environments. This innovative unit offers unmatched precision and flexibility, making it ideal for facilities that require meticulous temperature control and energy efficiency.

One of the main features of the Liebert EM is its modular design, allowing for easy expansion and customization based on the specific requirements of a facility. This scalability ensures that organizations can efficiently adapt to changing cooling demands without the need for significant infrastructure changes. The system can be configured in various capacities, making it suitable for spaces of different sizes and cooling needs.

Incorporating advanced technologies, the Liebert EM utilizes inverter-driven compressors, allowing for variable refrigeration capacity. This feature optimizes energy consumption, reducing operational costs while maintaining precise temperature control. The unit is designed with built-in smart controls that enable real-time monitoring and adjustments, ensuring enhanced performance and efficiency across the entire cooling system.

The Liebert EM also comes equipped with EC (Electronically Commutated) fans, which contribute to its energy efficiency by adjusting their speed according to the cooling load. This not only ensures adequate airflow but also minimizes energy waste, leading to lower overall operating costs.

Furthermore, the system features intelligent connectivity options that facilitate integration with existing building management systems. This capability allows for centralized monitoring and control, empowering facility managers to maintain optimal conditions and respond quickly to any fluctuations in temperature or humidity.

Safety and reliability are also paramount in the design of the Liebert EM. The unit includes comprehensive backup systems and redundancy features to ensure continuous operation even in the event of a component failure. This reliability is crucial for critical applications where downtime can result in significant losses.

In summary, the Liebert EM stands out as a versatile and high-performance cooling solution, equipped with advanced technologies that offer scalability, energy efficiency, and precise temperature control. Its modular design, coupled with intelligent control options, makes it an essential component for modern data centers looking to optimize their cooling infrastructure while ensuring reliability and reducing operational costs.