OPERATING INSTRUCTIONS

NORMAL MODE OPERATION

AC INPUT BATTERY UPS ON BYPASS

Normal Mode Operation at 26-50%

During normal operation, util- ity power provides energy to the UPS. The filters, power factor correction circuit and the inverter process this power to provide computer grade power to connected loads. The UPS maintains the batteries in a fully charged state.

The four green load level LEDs indicate an approximate level of load in 25% increments. If the UPS becomes loaded beyond full rating, the fifth (amber) LED indicator will illuminate and the UPS will sound an audible alarm. The display template indicates the percentage of load (26-50% of load shown in the example above) on the UPS output.

BYPASS MODE OPERATION

AC INPUT BATTERY UPS ON BYPASS

Bypass Mode Operation at 26-50%

Bypass mode occurs when the OFF button is pressed once while the UPS is in Normal Mode. During bypass opera- tion, utility power provides energy to the UPS. The utility power bypasses the inverter and provides power for the connected load.

The four green load level LEDs indicate an approximate level of load in 25% increments. If the UPS becomes loaded beyond full rating, the fifth (amber) LED indicator will illuminate and the UPS will sound an audible alarm. The display template indicates the percentage of load (26-50% of load shown in the example above) on the UPS output.

! CAUTION

Turning OFF the UPS while in bypass mode will result in loss of output power.

BATTERY MODE OPERATION

AC INPUT BATTERY UPS ON BYPASS

Battery Mode Operation at 80-61%

17

Battery mode occurs in event of an extreme input voltage condition or complete utility failure. The battery system supplies power through the DC to DC converter to the inverter to generate power for the connected load.

Image 21
Contents UPStation GXT 2U Page Table of Contents Configuration Program Important Safety Instructions Page Glossary of Symbols Introduction RECTIFIER/POWER Factor Correction PFC Circuit Major ComponentsInverter Battery Battery ChargerDC to DC Converter Dynamic BypassGXT 2U Rear View Installation Tower UPS InstallationPreparation RACK-MOUNT UPS Conversion and Installation Page Prepare the UPS or battery cab Inet the equipment for rack UPS External Battery Cabinet Installation ON/Alarm Silence/Manual Battery Test Button Controls and IndicatorsFault Indicator LED Red Load/Battery Level Indicators 4 Green, 1 AmberBypass Indicator LED Amber UPS on Indicator LED GreenOutput Voltage Selection AC Input Indicator LED GreenBypass Mode Operation Normal Mode OperationBattery Mode Operation Operating InstructionsBattery Recharge Mode Pins 4 & 5 Remote Shutdown on Battery CommunicationsCommunications Interface Port Auto-Enable Output Pin 6 Logic Pins 5 & 6 ANY-MODE ShutdownUPS Intelligent Communications Configuration Program GXT 2U Configuration Program AbilitiesWhat You Will Need Battery Replacement MaintenanceInternal Battery Replacement Procedures LED status Diagnosis/Audible alarm TroubleshootingProblem Cause Solution Troubleshooting GuideRoom ambient temperature That the bypass is Condition Alarm Alarm ConditionsDimensions in. mm SpecificationsDimensions in mm Battery Cabinet SpecificationsLoad % Estimated Time Battery RUN TimesProduct Warranty Registration Page Page UPStation GXT 2U

208V, 2700VA specifications

The Liebert 2700VA, 208V is a robust and reliable uninterruptible power supply (UPS) designed to protect critical electronic equipment from power disturbances. This UPS is ideal for various applications, including data centers, telecommunications, and manufacturing environments, ensuring that business continuity is maintained even in the face of power outages or fluctuations.

One of the primary features of the Liebert 2700VA is its high power rating of 2700VA, which makes it suitable for supporting a range of devices, from servers to sensitive electronic equipment. With a nominal output voltage of 208V, it meets the electrical requirements of many industrial and commercial systems, making it an adaptable choice for enterprises with diverse power needs.

The Liebert 2700VA is equipped with advanced technologies that enhance its performance and efficiency. The unit employs double-conversion online technology, which ensures that the output power is consistently clean and stable. This technology continuously converts incoming AC power into DC and then back to AC, providing a seamless transition to battery power during an outage, eliminating any momentary interruptions.

In terms of characteristics, the Liebert 2700VA features an LCD display that provides real-time information on the UPS’s status, including input/output voltage, load level, and battery condition. This user-friendly interface allows for easy monitoring and management, making it convenient for IT professionals to maintain optimal operations.

Another significant aspect of the Liebert 2700VA is its advanced battery management system. This feature optimizes battery performance and life by regulating charging cycles and ensuring that batteries are in peak condition when needed. Furthermore, the UPS offers multiple communication options, including USB and serial connectivity, enabling integration with monitoring software and allowing for remote management capabilities.

The Liebert 2700VA also comes equipped with a range of protection features, including overload protection, short-circuit protection, and surge suppression. These attributes safeguard connected equipment from electrical anomalies, providing peace of mind in environments where downtime can be costly.

In conclusion, the Liebert 2700VA, 208V is a powerful UPS solution that combines advanced technology with essential features, making it a crucial asset for businesses seeking reliable power protection. Its robust capabilities, user-friendly interface, and extensive protection measures position it as an ideal choice for ensuring operational continuity in various critical applications.