Liebert 208V, 2700VA user manual Preparation, Tower UPS Installation

Page 12

INSTALLATION

PREPARATION

1.Visually inspect the UPS for freight damage. Report damage to the carrier and your local dealer or Liebert representative.

! CAUTION

The UPS is heavy (see Specifications section). Take proper precautions when lifting or moving it.

2.Decide where to place the GXT 2U. Install the UPS indoors in a con- trolled environment, where it cannot be accidentally turned off. Place it in an area of unrestricted airflow around the unit, away from water, flammable liquids, gases, corrosives, and conductive contaminants. Maintain a minimum clearance of 4 inches (100mm) in the front and rear of the UPS. Maintain an ambient temperature range of 32°F to 104°F (0°C to 40°C).

NOTE

UPS operation in temperatures above 77°F (25°C) reduces battery life.

3.The GXT 2U may be installed in either a tower configuration or in a rack, depending on available space and use considerations. Deter- mine the type of installation and follow the appropriate instructions in either Tower UPS Installation or Rack-Mount UPS Conversion and Installation.

TOWER UPS INSTALLATION

When using the GXT 2U in a tower configuration, use the included sup- port base (shown below, left) to stabilize the UPS.

If any battery cabinets are added, they will include spacers to accommo- date the additional cabinets (shown below, right).

Support base

Spacers added to support

 

base to accommodate

 

additional battery cabinets

8

Image 12
Contents UPStation GXT 2U Page Table of Contents Configuration Program Important Safety Instructions Page Glossary of Symbols Introduction RECTIFIER/POWER Factor Correction PFC Circuit Major ComponentsInverter Battery Charger BatteryDC to DC Converter Dynamic BypassGXT 2U Rear View Installation Tower UPS InstallationPreparation RACK-MOUNT UPS Conversion and Installation Page Prepare the UPS or battery cab Inet the equipment for rack UPS External Battery Cabinet Installation Controls and Indicators ON/Alarm Silence/Manual Battery Test ButtonLoad/Battery Level Indicators 4 Green, 1 Amber Fault Indicator LED RedBypass Indicator LED Amber UPS on Indicator LED GreenAC Input Indicator LED Green Output Voltage SelectionNormal Mode Operation Bypass Mode OperationBattery Mode Operation Operating InstructionsBattery Recharge Mode Pins 4 & 5 Remote Shutdown on Battery CommunicationsCommunications Interface Port Pins 5 & 6 ANY-MODE Shutdown Auto-Enable Output Pin 6 LogicUPS Intelligent Communications Configuration Program GXT 2U Configuration Program AbilitiesWhat You Will Need Maintenance Battery ReplacementInternal Battery Replacement Procedures Troubleshooting LED status Diagnosis/Audible alarmTroubleshooting Guide Problem Cause SolutionRoom ambient temperature That the bypass is Alarm Conditions Condition AlarmSpecifications Dimensions in. mmBattery Cabinet Specifications Dimensions in mmBattery RUN Times Load % Estimated TimeProduct Warranty Registration Page Page UPStation GXT 2U

208V, 2700VA specifications

The Liebert 2700VA, 208V is a robust and reliable uninterruptible power supply (UPS) designed to protect critical electronic equipment from power disturbances. This UPS is ideal for various applications, including data centers, telecommunications, and manufacturing environments, ensuring that business continuity is maintained even in the face of power outages or fluctuations.

One of the primary features of the Liebert 2700VA is its high power rating of 2700VA, which makes it suitable for supporting a range of devices, from servers to sensitive electronic equipment. With a nominal output voltage of 208V, it meets the electrical requirements of many industrial and commercial systems, making it an adaptable choice for enterprises with diverse power needs.

The Liebert 2700VA is equipped with advanced technologies that enhance its performance and efficiency. The unit employs double-conversion online technology, which ensures that the output power is consistently clean and stable. This technology continuously converts incoming AC power into DC and then back to AC, providing a seamless transition to battery power during an outage, eliminating any momentary interruptions.

In terms of characteristics, the Liebert 2700VA features an LCD display that provides real-time information on the UPS’s status, including input/output voltage, load level, and battery condition. This user-friendly interface allows for easy monitoring and management, making it convenient for IT professionals to maintain optimal operations.

Another significant aspect of the Liebert 2700VA is its advanced battery management system. This feature optimizes battery performance and life by regulating charging cycles and ensuring that batteries are in peak condition when needed. Furthermore, the UPS offers multiple communication options, including USB and serial connectivity, enabling integration with monitoring software and allowing for remote management capabilities.

The Liebert 2700VA also comes equipped with a range of protection features, including overload protection, short-circuit protection, and surge suppression. These attributes safeguard connected equipment from electrical anomalies, providing peace of mind in environments where downtime can be costly.

In conclusion, the Liebert 2700VA, 208V is a powerful UPS solution that combines advanced technology with essential features, making it a crucial asset for businesses seeking reliable power protection. Its robust capabilities, user-friendly interface, and extensive protection measures position it as an ideal choice for ensuring operational continuity in various critical applications.