Table 5—Air Delivery - CFM (with Filter)*

FURNACE

RETURN---AIR

SPEED

 

 

 

EXTERNAL STATIC PRESSURE (In. W.C.)

 

 

SIZE

INLET

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

0.2

 

0.3

0.4

0.5

0.6

0.7

0.8

 

0.9

1.0

045---08/

Bottom or

High

1035

995

 

945

895

835

770

675

565

 

390

195

Med--- High

865

830

 

790

745

690

625

545

440

 

250

195

024045

Side(s)

 

 

Med--- Low

760

720

 

680

635

580

520

445

345

 

220

195

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

045---12/

Bottom or

High

1440

1375

 

1305

1240

1160

1070

975

870

 

730

560

Med--- High

1360

1300

 

1240

1175

1115

1040

950

850

 

725

575

036045

Side(s)

 

 

Med--- Low

1250

1210

 

1160

1100

1040

965

885

790

 

670

520

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

070---08/

Bottom or

High

1030

1005

 

965

925

870

810

740

645

 

465

280

Med--- High

835

815

 

790

755

710

660

590

480

 

325

205

024070

Side(s)

 

 

Med--- Low

725

700

 

675

635

595

545

460

350

 

250

--- ---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

070---12/

Bottom or

High

1425

1375

 

1320

1265

1200

1125

1035

940

 

830

655

Med--- High

1320

1280

 

1240

1205

1140

1075

995

905

 

790

620

036070

Side(s)

 

 

Med--- Low

1200

1175

 

1145

1105

1050

990

920

840

 

725

555

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

070---16/

Bottom or

High

1755

1700

 

1635

1570

1505

1435

1350

1260

 

1160

1055

Med--- High

1550

1520

 

1475

1430

1375

1310

1240

1155

 

1070

970

048070

Side(s)

 

 

Med--- Low

1355

1340

 

1310

1280

1240

1190

1125

1060

 

975

890

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

090---14/

Bottom or

High

1605

1570

 

1535

1465

1385

1285

1175

1055

 

895

645

Med--- High

1470

1445

 

1410

1380

1300

1220

1115

990

 

830

600

042090

Side(s)

 

 

Med--- Low

1310

1295

 

1265

1230

1195

1120

1025

915

 

710

565

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

090---16/

Bottom or

High

1940

1880

 

1805

1720

1635

1540

1425

1290

 

1090

830

Med--- High

1740

1700

 

1650

1590

1525

1440

1335

1195

 

1010

820

048090

Side(s)

 

 

Med--- Low

1505

1505

 

1480

1440

1375

1300

1190

1045

 

890

740

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

2405

2310

 

2220

2130

2025

1920

1790

1660

 

1530

1350

 

Bottom Only

Med--- High

2170

2110

 

2040

1970

1895

1785

1675

1565

 

1420

1260

 

 

Med--- Low

1920

1875

 

1835

1780

1715

1630

1535

1420

 

1275

1135

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

090---20/

Both Sides or 1

High

2530

2450

 

2365

2270

2165

2065

1940

1805

 

1670

1505

Med--- High

2230

2170

 

2110

2050

1985

1890

1780

1660

 

1525

1360

060090

Side & Bottom

 

 

Med--- Low

1895

1890

 

1845

1815

1755

1685

1600

1480

 

1350

1180

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

2475

2395

 

2300

2200

2090

1985

1865

1730

 

1585

1425

 

1Side Only

Med--- High

2105

2145

 

2070

2010

1940

1845

1735

1620

 

1475

1325

 

 

Med--- Low

1850

1860

 

1810

1770

1715

1650

1555

1445

 

1310

1150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110---12/

Bottom or

High

1600

1550

 

1490

1425

1355

1260

1135

990

 

785

530

Med--- High

1475

1435

 

1395

1335

1285

1185

1070

890

 

725

450

036110

Side(s)

 

 

Med--- Low

1315

1295

 

1265

1220

1155

1080

985

810

 

675

440

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110---16/

Bottom or

High

1980

1915

 

1835

1750

1655

1495

1365

1185

 

965

700

Med--- High

1745

1710

 

1650

1560

1450

1340

1205

1090

 

865

605

048110

Side(s)

 

 

Med--- Low

1530

1515

 

1470

1400

1310

1215

1095

990

 

830

670

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

2485

2415

 

2340

2255

2160

2080

1950

1840

 

1720

1565

 

Bottom Only

Med--- High

2135

2100

 

2060

2000

1930

1860

1765

1670

 

1555

1425

 

 

Med--- Low

1855

1840

 

1815

1775

1725

1675

1600

1510

 

1405

1290

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110---22/

Bottom Sides

High

--- ---

--- ---

 

2355

2285

2190

2090

1965

1850

 

1705

1535

or 1 Side & Bot-

Med--- High

2140

2100

 

2050

1990

1935

1865

1760

1670

 

1545

1410

066110

 

 

tom

Med--- Low

1855

1840

 

1815

1775

1725

1675

1600

1510

 

1405

1290

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

2495

2440

 

2370

2290

2205

2120

2015

1910

 

1775

1625

 

1Side Only

Med--- High

2030

2025

 

2000

1950

1905

1850

1750

1660

 

1555

1425

 

 

Med--- Low

--- ---

1735

 

1725

1695

1650

1595

1535

1455

 

1335

1230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* A filter is required

for each return ---air inlet. Airflow performance included 3/4

---in. (19 mm) washable filter media such as contained in factory

---authorized ac-

cessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.

 

 

--- --- Indicates unstable operating conditions.

 

 

 

 

 

 

 

 

 

 

 

 

14

Page 14
Image 14
Bryant 310AAV instruction manual Air Delivery CFM with Filter, Furnace RETURN---AIR Speed, Size Inlet

310AAV specifications

The Bryant 310AAV and 310JAV are high-efficiency air conditioning and heating systems designed for residential and light commercial applications. These models embody Bryant's commitment to delivering reliable comfort solutions while prioritizing energy efficiency and performance.

One of the standout features of the Bryant 310AAV and 310JAV is their impressive Seasonal Energy Efficiency Ratio (SEER) ratings. The higher the SEER, the more efficient the unit is in using electricity to cool your space. The Bryant 310AAV boasts a SEER rating of up to 16, while the 310JAV offers a slightly lower rating. This efficiency translates into cost savings on monthly energy bills while ensuring indoor comfort throughout the year.

Both models utilize advanced technologies, including two-stage heating and cooling capabilities. This means that the systems can adjust their operation based on the heating or cooling needs of a space, providing optimal temperature control while reducing energy waste. The two-stage operation also contributes to quieter operation levels, making these units suitable for residential settings where noise is a concern.

The 310AAV and 310JAV are equipped with variable-speed compressors, which further enhance their efficiency and comfort levels. The variable-speed technology allows the system to operate at different speeds, ensuring consistent temperature management and reducing the frequency of on-and-off cycling. This leads to steadier indoor temperatures and improved humidity control.

In addition to their performance features, Bryant places a strong emphasis on durability and dependability. The units are constructed with high-quality materials that are designed to withstand various environmental conditions. Features such as a weather-resistant cabinet and an efficient coil design help protect the units from wear and tear, ensuring long-lasting performance.

The implementation of environmentally friendly refrigerant options is another characteristic that demonstrates Bryant's commitment to sustainability. Both the 310AAV and 310JAV utilize R-410A refrigerant, which has a lower environmental impact compared to older refrigerants, aligning with modern standards for eco-friendly HVAC systems.

Overall, the Bryant 310AAV and 310JAV represent a blend of efficiency, advanced technology, and durability. With their attractive SEER ratings, two-stage operation, variable-speed capabilities, and commitment to sustainability, these models stand out as excellent choices for homeowners and businesses looking to enhance their heating and cooling solutions while keeping energy consumption in check. Whether for residential comfort or light commercial use, these Bryant units promise reliability and performance for years to come.