Table 3—Minimum Space Volumes for 100% Combustion, Ventilation, and Dilution from Indoors

OTHER THAN FAN-ASSISTED TOTAL

 

 

FAN-ASSISTED TOTAL

 

 

 

(1,000’S BTUH GAS INPUT RATE)

 

(1,000’S BTUH GAS INPUT RATE)

 

ACH

 

30

40

50

44

66

88

110

132

154

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Space Volume Ft3 (M3)

 

 

 

 

 

 

 

 

 

 

 

0.60

 

1,050

1,400

1,750

1,100

1,650

2,200

2,750

3,300

3,850

 

(29.7)

(39.6)

(49.5)

(31.1)

(46.7)

(62.2)

(77.8)

(93.4)

(109.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

0.50

 

1,260

1,680

2,100

1,320

1,980

2,640

3,300

3,960

4,620

 

(35.6)

(47.5)

(59.4)

(37.3)

(56.0)

(74.7)

(93.4)

(112.1)

(130.8)

 

 

0.40

 

1,575

2,100

2,625

1,650

2,475

3,300

4,125

4,950

5,775

 

(44.5)

(59.4)

(74.3)

(46.7)

(70.0)

(93.4)

(116.8)

(140.1)

(163.5)

 

 

0.30

 

2,100

2,800

3,500

2,200

3,300

4,400

5,500

6,600

7,700

 

(59.4)

(79.2)

(99.1)

(62.2)

(93.4)

(124.5)

(155.7)

(186.8)

(218.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

0.20

 

3,150

4,200

5,250

3,300

4,950

6,600

8,250

9,900

11,550

 

(89.1)

(118.9)

(148.6)

(93.4)

(140.1)

(186.8)

(233.6)

(280.3)

(327.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

0.10

 

6,300

8,400

10,500

6,600

9,900

13,200

16,500

19,800

23,100

 

(178.3)

(237.8)

(297.3)

(186.8)

(280.3)

(373.7)

(467.2)

(560.6)

(654.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

0.00

 

NP

NP

NP

NP

NP

NP

NP

NP

NP

 

 

 

 

 

 

 

 

 

 

 

NP = Not Permitted

 

 

 

 

 

1 SQ IN.

 

CIRCULATING AIR

 

 

 

 

DUCTS

 

PER 4000

 

VENT THROUGH ROOF

 

 

 

BTUH*

 

DUCTS

 

 

 

 

TO

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOORS

 

 

 

 

 

 

 

 

 

D

12

 

 

AIR

12" MAX (305mm)

(305mm) 12 MAX

 

 

 

(305mm)

 

FRONTINCLEARANCEOF COMBUSTION SHALLOPENINGSBE AT LEAST3 IN.

 

BTUH*

 

FRONTINCLEARANCE

AIRCOMBUSTIONOF BESHALLOPENINGS .IN3LEASTAT

(76mm)

MAX

 

 

 

12

 

 

 

1 SQ IN.

B

TINGCIRCULA

DUCTSAIR

VENT

 

 

 

 

 

PER 2000

 

 

THROUGH

F

 

 

 

1 SQ IN.

BTUH*

 

 

 

ROOF

1 SQ IN.

 

 

 

PER 1000

 

 

 

 

 

 

 

 

BTUH* IN DOOR

 

 

 

 

 

PER

 

 

 

OR WALL

 

 

 

 

 

4000

 

 

 

 

 

 

 

 

 

BTUH*

 

INTERIOR

 

UNCONFINED

 

 

 

 

 

OUTDOORS

 

HEATED

 

SPACE

DUCTS

 

 

 

 

 

 

SPACE

 

6" MIN (152mm)

TO

 

 

 

 

 

 

 

 

OUTDOORS

 

 

 

 

 

 

 

 

(FRONT)Ü

 

 

 

 

 

1 SQ IN.

 

 

 

1 SQ IN.

 

 

 

 

 

PER

 

 

 

PER 1000

 

 

 

 

 

4000

 

 

 

BTUH* IN DOOR

1 SQ IN.

 

 

 

 

BTUH*

 

 

 

OR WALL

 

 

 

E

G

 

 

 

 

PER 2000

A

 

 

 

 

 

 

(305mm) 12MAX

 

 

 

C

MAX (305mm)

 

 

12" MAX (305mm)

 

 

 

 

12MAX

 

 

 

 

 

 

 

 

(305mm)

 

CIRCULATING AIR DUCTS

 

 

 

 

 

 

 

 

 

 

 

CIRCULATING AIR DUCTS

DUCT

1 SQ IN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO

PER 4000

 

 

 

 

 

 

 

 

OUTDOORS

BTUH*

 

 

 

 

*Minimum dimensions of 3--- in. (76 mm).

 

 

* Minimum opening size is 100 sq in. (64516 sq. mm)with minimum dimensions

NOTE: Use any of the following combinations of openings:

 

of 3 in. (76 mm)

 

 

A & B C & D D & E F & G

 

 

 

† Minimum of 3 in. (76 mm) when type-B1 vent is used.

 

 

 

 

 

 

A03174

 

 

A03175

Fig. 7 ---Air for Combustion, Ventilation, and Dilution for

Fig. 8 ---Air for Combustion, Ventilation, and Dilution from

Outdoors

Indoors

310AAV

9

Page 9
Image 9
Bryant 310AAV instruction manual Other than FAN-ASSISTED Total

310AAV specifications

The Bryant 310AAV and 310JAV are high-efficiency air conditioning and heating systems designed for residential and light commercial applications. These models embody Bryant's commitment to delivering reliable comfort solutions while prioritizing energy efficiency and performance.

One of the standout features of the Bryant 310AAV and 310JAV is their impressive Seasonal Energy Efficiency Ratio (SEER) ratings. The higher the SEER, the more efficient the unit is in using electricity to cool your space. The Bryant 310AAV boasts a SEER rating of up to 16, while the 310JAV offers a slightly lower rating. This efficiency translates into cost savings on monthly energy bills while ensuring indoor comfort throughout the year.

Both models utilize advanced technologies, including two-stage heating and cooling capabilities. This means that the systems can adjust their operation based on the heating or cooling needs of a space, providing optimal temperature control while reducing energy waste. The two-stage operation also contributes to quieter operation levels, making these units suitable for residential settings where noise is a concern.

The 310AAV and 310JAV are equipped with variable-speed compressors, which further enhance their efficiency and comfort levels. The variable-speed technology allows the system to operate at different speeds, ensuring consistent temperature management and reducing the frequency of on-and-off cycling. This leads to steadier indoor temperatures and improved humidity control.

In addition to their performance features, Bryant places a strong emphasis on durability and dependability. The units are constructed with high-quality materials that are designed to withstand various environmental conditions. Features such as a weather-resistant cabinet and an efficient coil design help protect the units from wear and tear, ensuring long-lasting performance.

The implementation of environmentally friendly refrigerant options is another characteristic that demonstrates Bryant's commitment to sustainability. Both the 310AAV and 310JAV utilize R-410A refrigerant, which has a lower environmental impact compared to older refrigerants, aligning with modern standards for eco-friendly HVAC systems.

Overall, the Bryant 310AAV and 310JAV represent a blend of efficiency, advanced technology, and durability. With their attractive SEER ratings, two-stage operation, variable-speed capabilities, and commitment to sustainability, these models stand out as excellent choices for homeowners and businesses looking to enhance their heating and cooling solutions while keeping energy consumption in check. Whether for residential comfort or light commercial use, these Bryant units promise reliability and performance for years to come.