Liebert 1000 - 3000VA 60 Hz 120V user manual Table of Contents

Page 3

TABLE OF CONTENTS

IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.0 GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.0 MAJOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.1 Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters. . . . . . . . . . . . . . . . . . . . 6

3.2 Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.3 Automatic Voltage Regulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3.4 Battery Charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3.5 Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3.6 Inverter—1000/1440 Models Only. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3.7 DC-to-DCConverter—1920/2200/3000 Models Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3.8 Bi-DirectionalConverter—1920/2200/3000 Models Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4.0 WHATS INCLUDED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 5.0 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

5.1 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5.2 Tower UPS Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5.3 Rack-Mount UPS Conversion and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

5.4 External Battery Cabinet Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

6.0 CONTROLS AND INDICATORS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

6.1 ON/Alarm Silence/Battery Test Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 6.2 OFF Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 6.3 Voltage Programming Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 6.4 Load Level Indicators—4 green, 1 amber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 6.5 Battery Level Indicators—5 green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 6.6 AC Input Indicator—Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 6.7 Buck/Boost Indicator—Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 6.8 Battery Indicator—Green/Amber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 6.9 Over Temp Indicator—Amber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 6.10 Fault Indicator—Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

7.0 MODES OF OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

7.1 Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

i

Image 3
Contents Liebert PowerSure PSI Page Table of Contents Communications Product Warranty RegistrationFigures Page Safety Precautions Important Safety InstructionsBattery Handling Precautions Glossary of Symbols Front view of UPS Introduction3000VA PSI-rear view Major Components RelayInverter-1000/1440 Models Only Battery ChargerBattery Automatic Voltage RegulatorWHAT’S Included Tower UPS Installation InstallationPreparation Rack mount handles Rack-Mount UPS Conversion and InstallationRack mounting rails and slide assemblies Option 1 Serial Communications Repo switch connections External Battery Cabinet InstallationON/Alarm Silence/Battery Test Button Controls and IndicatorsOFF Button Buck/Boost Indicator-Green Load Level Indicators-4 green, 1 amberBattery Level Indicators-5 green AC Input Indicator-GreenFault Indicator-Red Over Temp Indicator-AmberNormal Mode Buck/Boost ModeModes of Operation Battery Recharge Operation Battery ModeDB-9 Connector Remote Shutdown Via the DB-9 ConnectorCommunications Data Line Protection Connectors USB Interface PortUPS Intelligent Communications Utility power will be applied to the connected load Voltage Programming ProcedureMaintaining Batteries Cleaning the UPSBattery Replacement MaintenanceInternal Battery Replacement Procedure Status indicators TroubleshootingTroubleshooting chart Problem Cause Solution UPS specifications SpecificationsBattery cabinet specifications Battery run times Product Warranty Registration Site Nic

1000 - 3000VA 60 Hz 120V specifications

The Liebert 1000 - 3000VA 60 Hz 120V is an uninterruptible power supply (UPS) designed to protect critical electronic equipment and ensure uninterrupted operation in various settings. Ideal for small to medium-sized businesses, the Liebert UPS offers reliable power protection with its compact and efficient design.

One of the main features of the Liebert 1000 - 3000VA is its advanced battery technology. Equipped with high-performance sealed lead-acid batteries, this UPS ensures long-lasting power backup while requiring minimal maintenance. The smart battery management system intelligently monitors battery health, extending overall battery life while providing precise notifications for replacement, thus optimizing operational efficiency.

Another critical characteristic is its online double-conversion technology. This feature provides consistent and clean power by converting incoming AC power to DC and then back to AC again. This process effectively eliminates any electrical noise or power fluctuations, protecting sensitive electronics from interruptions or damage caused by power surges, spikes, or drops. As a result, workloads can operate without concern for potential power issues.

The Liebert UPS is designed with user-friendliness in mind. Featuring a clear LED display, it allows users to easily monitor performance metrics such as load level, battery health, and runtime status. In addition, the intuitive control panel simplifies operation and navigation through settings, making it accessible to users without extensive technical knowledge.

This UPS also offers flexibility with multiple outlet options. The Liebert 1000 - 3000VA includes a combination of NEMA outlets, providing compatibility with various equipment types, from servers and routers to networking devices and communications equipment. This versatility ensures that it meets diverse power requirements within any environment.

Moreover, the compact form factor enables installation in tight spaces while maintaining robust performance. Its efficient design facilitates heat dissipation, ensuring optimal operation without overheating.

The Liebert 1000 - 3000VA 60 Hz 120V UPS delivers excellent protection for critical equipment across various industries, including telecommunications, healthcare, and finance, ensuring operational continuity. With its advanced features, reliable technologies, and user-centered design, it stands out as a reliable choice for any organization seeking to safeguard its power supply infrastructure.