Specifications

Table 5

Battery run times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Load%

1000VA

1440VA

1920VA

2200VA

3000VA

 

 

5%

174

138

181

171

177

 

 

10%

118

79

104

73

91

 

 

20%

65

45

52

47

47

 

 

30%

41

28

31

26

28

Internal Battery

40%

37

24

25

23

22

50%

26

16

19

16

16

(minutes)

 

 

60%

24

14

15

13

14

 

 

 

 

70%

18

10

11

10

10

 

 

80%

16

9

10

8

9

 

 

90%

12

6

8

6

7

 

 

100%

11

5

6

5

6

 

 

5%

513

409

575

542

542

 

 

10%

305

265

294

266

257

 

 

20%

248

188

208

185

148

Internal Battery

30%

177

125

143

135

141

40%

139

104

123

122

99

+ 1 External

50%

119

72

105

99

67

Battery Cabinet

60%

98

59

82

75

53

(minutes)

 

 

 

70%

75

45

59

55

45

 

 

80%

63

40

53

49

39

 

 

90%

53

35

47

44

34

 

 

100%

46

30

43

40

29

 

 

5%

1001

828

 

 

10%

565

461

590

493

444

 

 

20%

409

283

307

291

249

Internal Battery

30%

283

219

243

222

168

40%

248

177

197

194

148

+ 2 External

50%

209

133

163

150

129

Battery Cabinets

60%

166

122

141

137

114

(minutes)

 

 

 

70%

136

98

128

122

92

 

 

80%

127

84

115

107

71

 

 

90%

110

64

102

92

56

 

 

100%

98

56

89

77

52

 

 

5%

1174

1001

 

 

10%

1001

655

590

 

 

20%

565

409

522

493

300

Internal Battery

30%

409

283

298

283

240

40%

305

257

267

266

213

+ 3 External

50%

274

209

237

222

168

Battery Cabinets

60%

248

166

197

185

144

(minutes)

 

 

 

70%

209

136

166

156

129

 

 

80%

188

125

147

141

116

 

 

90%

145

110

138

131

101

 

 

100%

136

95

128

120

88

 

 

5%

1174

 

 

10%

1174

828

 

 

20%

828

565

639

590

444

Internal Battery

30%

513

357

458

395

283

40%

461

292

322

300

266

+ 4 External

50%

305

257

281

274

222

Battery Cabinets

60%

283

230

252

240

179

(minutes)

 

 

 

70%

257

188

220

203

150

 

 

80%

239

156

192

173

139

 

 

90%

209

136

169

156

129

 

 

100%

188

125

150

144

118

NOTE

Approximate discharge times are in minutes and at 77°F (25°C) with resistive load.

28

Image 34
Contents Liebert PowerSure PSI Page Table of Contents Product Warranty Registration CommunicationsFigures Page Important Safety Instructions Safety PrecautionsBattery Handling Precautions Glossary of Symbols Introduction Front view of UPS3000VA PSI-rear view Relay Major ComponentsAutomatic Voltage Regulator Battery ChargerBattery Inverter-1000/1440 Models OnlyWHAT’S Included Installation Tower UPS InstallationPreparation Rack-Mount UPS Conversion and Installation Rack mount handlesRack mounting rails and slide assemblies Option 1 Serial Communications External Battery Cabinet Installation Repo switch connectionsControls and Indicators ON/Alarm Silence/Battery Test ButtonOFF Button AC Input Indicator-Green Load Level Indicators-4 green, 1 amberBattery Level Indicators-5 green Buck/Boost Indicator-GreenOver Temp Indicator-Amber Fault Indicator-RedBuck/Boost Mode Normal ModeModes of Operation Battery Mode Battery Recharge OperationRemote Shutdown Via the DB-9 Connector DB-9 ConnectorCommunications USB Interface Port Data Line Protection ConnectorsUPS Intelligent Communications Voltage Programming Procedure Utility power will be applied to the connected loadMaintenance Cleaning the UPSBattery Replacement Maintaining BatteriesInternal Battery Replacement Procedure Troubleshooting Status indicatorsTroubleshooting chart Problem Cause Solution Specifications UPS specificationsBattery cabinet specifications Battery run times Product Warranty Registration Nic Site

1000 - 3000VA 60 Hz 120V specifications

The Liebert 1000 - 3000VA 60 Hz 120V is an uninterruptible power supply (UPS) designed to protect critical electronic equipment and ensure uninterrupted operation in various settings. Ideal for small to medium-sized businesses, the Liebert UPS offers reliable power protection with its compact and efficient design.

One of the main features of the Liebert 1000 - 3000VA is its advanced battery technology. Equipped with high-performance sealed lead-acid batteries, this UPS ensures long-lasting power backup while requiring minimal maintenance. The smart battery management system intelligently monitors battery health, extending overall battery life while providing precise notifications for replacement, thus optimizing operational efficiency.

Another critical characteristic is its online double-conversion technology. This feature provides consistent and clean power by converting incoming AC power to DC and then back to AC again. This process effectively eliminates any electrical noise or power fluctuations, protecting sensitive electronics from interruptions or damage caused by power surges, spikes, or drops. As a result, workloads can operate without concern for potential power issues.

The Liebert UPS is designed with user-friendliness in mind. Featuring a clear LED display, it allows users to easily monitor performance metrics such as load level, battery health, and runtime status. In addition, the intuitive control panel simplifies operation and navigation through settings, making it accessible to users without extensive technical knowledge.

This UPS also offers flexibility with multiple outlet options. The Liebert 1000 - 3000VA includes a combination of NEMA outlets, providing compatibility with various equipment types, from servers and routers to networking devices and communications equipment. This versatility ensures that it meets diverse power requirements within any environment.

Moreover, the compact form factor enables installation in tight spaces while maintaining robust performance. Its efficient design facilitates heat dissipation, ensuring optimal operation without overheating.

The Liebert 1000 - 3000VA 60 Hz 120V UPS delivers excellent protection for critical equipment across various industries, including telecommunications, healthcare, and finance, ensuring operational continuity. With its advanced features, reliable technologies, and user-centered design, it stands out as a reliable choice for any organization seeking to safeguard its power supply infrastructure.