Lantronix 4092A IRIG-B manual Selecting the Active Input Channel

Page 12

To assign the static IP address using Telnet:

1.Telnet to the assigned address, port 9999.

2.Press Enter within five seconds to enter the setup mode.

3.Select Option 0.

4.Set the IP address and follow the on-screen instructions to save the setting.

5.Telnet to the new IP address.

6.Type I

„You do not need to type a carriage return or line feed.

„The system returns I4092A-00\r\n, where the 00 is the hardware version, and turns on the front panel input LEDs for two seconds before returning to normal operation.

„If you see these responses, you know you are communicating with the unit.

2.4Selecting the Active Input Channel

You can select the active input channel using either the toggle switch on the front panel or remotely using the Ethernet connection.

To select the active input channel from the front panel:

1.Move the toggle switch by pulling the switch out, then moving it to the channel you want to use.

„The LED for the selected channel should be solid green.

2.If you want the unit to automatically switch to the other input channel in the event of a failure, move the toggle switch back to the center position.

„This puts the unit into autoswitch mode.

To select the active input channel remotely:

1.Telnet to the 4092A’s IP address.

„No prompt displays in the Telnet window.

2.Type either A or B, depending on which channel you want to select.

„You do not need to type a carriage return or line feed.

„The LED on the for the selected channel flashes green, showing that the channel has been selected remotely. It continues to flash green until you select the channel using the toggle switch on the front panel or set the unit to autoswitch mode.

3.If you want the unit to automatically switch to the other input channel in the event of a failure, type: C

„The LED for the selected channel changes to solid green, showing that the channel is active and the unit is in autoswitch mode.

8

2: Installing and Setting Up the 4092A

Image 12
Contents Walnut Street Suite 1B Boulder, CO Phone 303 Revision Description Date Approved Contents Glossary Index Symbols Symbol DefinitionIntroduction About This Manual ConventionsConvention Definition AC Power Ethernet 4092A OverviewIntroduction Installing and Setting Up the 4092A Safety InformationInstalling the 4092A To set up the 4092A Assigning a Static IP Address4092A Operations and Maintenance Manual To assign the static IP address using Telnet Selecting the Active Input ChannelTo select the active input channel from the front panel To select the active input channel remotelySetting the 4092A to Autoswitch Mode CleaningTo set the 4092A to autoswitch mode from the front panel To set the 4092A to autoswitch mode remotelyInstalling and Setting Up the 4092A Accessing the System Checking Status and AlarmsMonitoring the 4092A Checking System InformationDefines each status or alarm bit position Command sent 4092A response Checking Model Number and Software Version To check the TSC model numberTo check the software version Understanding Alarm Output Monitoring the 4092A Troubleshooting the 4092A Troubleshooting Input ProblemsInput LED status What it means What do to Troubleshooting Output Problems Troubleshooting Power Supply ProblemsPower LED status What it means What do to Input Select LED status What it means What do toConfiguring for Input Signal and Impedance Configuring for Dual Power SuppliesTo change the jumper settings Replacing Power Supplies To change the jumper settingVerifying Operational Problems To replace a power supplyReplacing Fuses To replace a fuseTroubleshooting the 4092A Warranty and Shipping Information Warranty InformationShipping Information Packing InstructionsWarranty and Shipping Information Appendix a Specifications Electrical SpecificationsSpecification Physical Specifications Environment SpecificationsTemperature Relative Humidity Altitude Glossary Glossary Index NumericsIndex

4092A IRIG-B specifications

The Lantronix 4092A IRIG-B is a high-performance time code generation and distribution module that plays a crucial role in various applications requiring precise time synchronization. This compact device is particularly beneficial in systems such as telecom infrastructure, military applications, satellite communications, and scientific research. Its core functionality revolves around generating and managing the IRIG-B time code, a standard used for accurately transmitting time information.

One of the primary features of the Lantronix 4092A is its versatility in time code generation. It supports both unidirectional and bidirectional protocols, allowing for seamless integration into existing systems. The module can generate multiple IRIG-B formats, ensuring compatibility with a wide range of time synchronization devices. This flexibility is a significant advantage, particularly in environments that utilize various time code standards.

The device employs advanced timekeeping technology that ensures high accuracy and stability. Equipped with a GPS input option, the 4092A can synchronize its time code with GPS signals, obtaining precise time data globally. This feature is essential for applications that demand synchronization across extensive networks and geographical locations.

In terms of connectivity, the Lantronix 4092A IRIG-B offers multiple options, including RS-232 and RS-485 interfaces. This variety enhances its compatibility with various systems and makes installation straightforward. Additionally, the module is designed for easy integration, enabling developers to embed it within existing hardware architectures without significant modifications.

The 4092A also boasts user-friendly configuration capabilities. Its setup can be managed through a serial interface, allowing users to define parameters and adjust settings with ease. This feature ensures that the device can be quickly tailored to meet the specific needs of the application, minimizing downtime during deployment.

In conclusion, the Lantronix 4092A IRIG-B is an essential module for any application that requires robust time synchronization. Its main features, including versatile time code generation, advanced timekeeping technology, multiple connectivity options, and user-friendly configuration, make it an outstanding choice for industries where precision timing is critical. With its reliability and adaptability, the 4092A is poised to meet the challenges of modern time-sensitive applications.