Lantronix 4092A IRIG-B manual Index, Numerics

Page 33

Index

Numerics

 

4092A

 

accessing remotely 11

alarms 15

 

cleaning 9

 

command interface 11

front panel

3

installing 5

 

monitoring

11

overview 3

 

rear panel 3

required cables 5

specifications 25

unpacking 5

A

accessing the 4092A remotely 11 active input channel

selecting from the front panel 8 selecting remotely 8

alarms checking 11 understanding 15

assigning gateway address 6 IP address 6 subnet mask 6

autoswitch mode

setting from the front panel 9 setting remotely 9

C cables

connecting 5 required 5

checking alarms 11 system status 11

the model number 14 the software version 14

cleaning the 4092A 9 Command-And-Response Port, explained 11 commands

for checking status and alarms 11

for selecting the active input channel 8 for setting autoswitch mode 9

connections Ethernet 3, 5 input power 5 input signal 3 input signals 5 output signal 3 output signals 5 power 3

conventions, typographic 2

D

DeviceInstaller software 7

dual power supplies, configuring for 19

E

earth symbol 1 Ethernet

connecting 5, 11 port 3, 6, 11

F

fuse replacing 21 symbol 1

G

gateway address, assigning 6

I

information shipping 23

input connector 3 LEDs 3

input channel

selecting active from the front panel 8 selecting active remotely 8

input select LED 3 input signals

connecting 5 specifications 25 troubleshooting 17

installing the 4092A 5 IP address assigning 6

L LAN

assigning an IP address 6 connecting 5

LAN port symbol 1

Lantronix DeviceInstaller software 7 Lantronix Xport. See Xport.

LEDs input 3 input select 3 output 3 power 3

M

model number, checking 14 monitoring the 4092A 11

N

network

assigning an IP address 6

4092A Operations and Maintenance Manual

29

Image 33
Contents Walnut Street Suite 1B Boulder, CO Phone 303 Revision Description Date Approved Contents Glossary Index Symbols Symbol DefinitionIntroduction About This Manual ConventionsConvention Definition 4092A Overview AC Power EthernetIntroduction Installing and Setting Up the 4092A Safety InformationInstalling the 4092A Assigning a Static IP Address To set up the 4092A4092A Operations and Maintenance Manual Selecting the Active Input Channel To assign the static IP address using TelnetTo select the active input channel from the front panel To select the active input channel remotelyCleaning Setting the 4092A to Autoswitch ModeTo set the 4092A to autoswitch mode from the front panel To set the 4092A to autoswitch mode remotelyInstalling and Setting Up the 4092A Checking Status and Alarms Accessing the SystemMonitoring the 4092A Checking System InformationDefines each status or alarm bit position Command sent 4092A response Checking Model Number and Software Version To check the TSC model numberTo check the software version Understanding Alarm Output Monitoring the 4092A Troubleshooting the 4092A Troubleshooting Input ProblemsInput LED status What it means What do to Troubleshooting Power Supply Problems Troubleshooting Output ProblemsPower LED status What it means What do to Input Select LED status What it means What do toConfiguring for Input Signal and Impedance Configuring for Dual Power SuppliesTo change the jumper settings To change the jumper setting Replacing Power SuppliesTo replace a power supply Verifying Operational ProblemsReplacing Fuses To replace a fuseTroubleshooting the 4092A Warranty Information Warranty and Shipping InformationShipping Information Packing InstructionsWarranty and Shipping Information Appendix a Specifications Electrical SpecificationsSpecification Physical Specifications Environment SpecificationsTemperature Relative Humidity Altitude Glossary Glossary Numerics IndexIndex

4092A IRIG-B specifications

The Lantronix 4092A IRIG-B is a high-performance time code generation and distribution module that plays a crucial role in various applications requiring precise time synchronization. This compact device is particularly beneficial in systems such as telecom infrastructure, military applications, satellite communications, and scientific research. Its core functionality revolves around generating and managing the IRIG-B time code, a standard used for accurately transmitting time information.

One of the primary features of the Lantronix 4092A is its versatility in time code generation. It supports both unidirectional and bidirectional protocols, allowing for seamless integration into existing systems. The module can generate multiple IRIG-B formats, ensuring compatibility with a wide range of time synchronization devices. This flexibility is a significant advantage, particularly in environments that utilize various time code standards.

The device employs advanced timekeeping technology that ensures high accuracy and stability. Equipped with a GPS input option, the 4092A can synchronize its time code with GPS signals, obtaining precise time data globally. This feature is essential for applications that demand synchronization across extensive networks and geographical locations.

In terms of connectivity, the Lantronix 4092A IRIG-B offers multiple options, including RS-232 and RS-485 interfaces. This variety enhances its compatibility with various systems and makes installation straightforward. Additionally, the module is designed for easy integration, enabling developers to embed it within existing hardware architectures without significant modifications.

The 4092A also boasts user-friendly configuration capabilities. Its setup can be managed through a serial interface, allowing users to define parameters and adjust settings with ease. This feature ensures that the device can be quickly tailored to meet the specific needs of the application, minimizing downtime during deployment.

In conclusion, the Lantronix 4092A IRIG-B is an essential module for any application that requires robust time synchronization. Its main features, including versatile time code generation, advanced timekeeping technology, multiple connectivity options, and user-friendly configuration, make it an outstanding choice for industries where precision timing is critical. With its reliability and adaptability, the 4092A is poised to meet the challenges of modern time-sensitive applications.