Lantronix 4092A IRIG-B manual Replacing Power Supplies, To change the jumper setting

Page 24

Caution

When opening the top cover and changing the power supply settings, use proper ESD precautions. This includes ensuring that you are properly grounded before touching the internal PWA of the unit to change the jumper settings.

Required for this procedure:

„#1 Phillips screwdriver

To change the jumper setting:

1.Disconnect both power supplies from their power source.

2.Using a #1 Phillips screwdriver, remove the top cover.

3.Move the jumper one position to the left to the 2S position.

Power supply jumper configured for one power supply (in the 1S position).

4.Replace the top cover.

5.Reconnect the power supplies.

4.6Replacing Power Supplies

For units with a single power supply, the normal LED state is for one LED to be green and the other not lit. For units with dual power supplies, the normal LED state is for both LEDs to be green.

If a power supply LED is red, check that the affected power supply is connected to a properly functioning 100–240 VAC, 50/60 Hz power source. If the LED remains red, you should replace the power supply.

For AC power supplies, use only TSC 4501A power supplies. For DC power supplies, use only TSC 4502A power supplies.

In a unit with dual power supplies, you can hot swap the power supplies. This means you can leave the working power supply connected to power and all input and output devices connected when you replace the failed power supply.

20

4: Troubleshooting the 4092A

Image 24
Contents Walnut Street Suite 1B Boulder, CO Phone 303 Revision Description Date Approved Contents Glossary Index Symbols Symbol DefinitionIntroduction About This Manual ConventionsConvention Definition AC Power Ethernet 4092A OverviewIntroduction Installing and Setting Up the 4092A Safety InformationInstalling the 4092A To set up the 4092A Assigning a Static IP Address4092A Operations and Maintenance Manual To assign the static IP address using Telnet Selecting the Active Input ChannelTo select the active input channel from the front panel To select the active input channel remotelySetting the 4092A to Autoswitch Mode CleaningTo set the 4092A to autoswitch mode from the front panel To set the 4092A to autoswitch mode remotelyInstalling and Setting Up the 4092A Accessing the System Checking Status and AlarmsMonitoring the 4092A Checking System InformationDefines each status or alarm bit position Command sent 4092A response Checking Model Number and Software Version To check the TSC model numberTo check the software version Understanding Alarm Output Monitoring the 4092A Troubleshooting the 4092A Troubleshooting Input ProblemsInput LED status What it means What do to Troubleshooting Output Problems Troubleshooting Power Supply ProblemsPower LED status What it means What do to Input Select LED status What it means What do toConfiguring for Input Signal and Impedance Configuring for Dual Power SuppliesTo change the jumper settings Replacing Power Supplies To change the jumper settingVerifying Operational Problems To replace a power supplyReplacing Fuses To replace a fuseTroubleshooting the 4092A Warranty and Shipping Information Warranty InformationShipping Information Packing InstructionsWarranty and Shipping Information Appendix a Specifications Electrical SpecificationsSpecification Physical Specifications Environment SpecificationsTemperature Relative Humidity Altitude Glossary Glossary Index NumericsIndex

4092A IRIG-B specifications

The Lantronix 4092A IRIG-B is a high-performance time code generation and distribution module that plays a crucial role in various applications requiring precise time synchronization. This compact device is particularly beneficial in systems such as telecom infrastructure, military applications, satellite communications, and scientific research. Its core functionality revolves around generating and managing the IRIG-B time code, a standard used for accurately transmitting time information.

One of the primary features of the Lantronix 4092A is its versatility in time code generation. It supports both unidirectional and bidirectional protocols, allowing for seamless integration into existing systems. The module can generate multiple IRIG-B formats, ensuring compatibility with a wide range of time synchronization devices. This flexibility is a significant advantage, particularly in environments that utilize various time code standards.

The device employs advanced timekeeping technology that ensures high accuracy and stability. Equipped with a GPS input option, the 4092A can synchronize its time code with GPS signals, obtaining precise time data globally. This feature is essential for applications that demand synchronization across extensive networks and geographical locations.

In terms of connectivity, the Lantronix 4092A IRIG-B offers multiple options, including RS-232 and RS-485 interfaces. This variety enhances its compatibility with various systems and makes installation straightforward. Additionally, the module is designed for easy integration, enabling developers to embed it within existing hardware architectures without significant modifications.

The 4092A also boasts user-friendly configuration capabilities. Its setup can be managed through a serial interface, allowing users to define parameters and adjust settings with ease. This feature ensures that the device can be quickly tailored to meet the specific needs of the application, minimizing downtime during deployment.

In conclusion, the Lantronix 4092A IRIG-B is an essential module for any application that requires robust time synchronization. Its main features, including versatile time code generation, advanced timekeeping technology, multiple connectivity options, and user-friendly configuration, make it an outstanding choice for industries where precision timing is critical. With its reliability and adaptability, the 4092A is poised to meet the challenges of modern time-sensitive applications.