GarrettCom Magnum 20X manual Locating the Magnum 200X Two-Port Repeater, Connecting Ethernet Media

Page 25

3.1Locating the Magnum 200X Two-Port Repeater

The location of the Magnum 200X Two-Port Repeater is dependent on the physical layout of the network and the area to be served. The unit should be set -up in a location that will accommodate easy and equal access to planned network devices and/or segment connections.

Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 200X repeater site. The rugged steel case of the Magnum 200X will protect it from accidental damage in a wiring closet or in a workplace setting. Keep an open area around the unit so that convection cooling can occur while the unit is in operation.

3.1.1Magnum 200X Table-Top / Shelf Mounting

The Magnum 200X unit has four rubber feet to provide stability while not scratching finished surfaces. It is typically shelf-mounted either in a wiring closet or in an open area. To conserve shelf space, it may be desirable to mount several units on top of each other. If so, this may be readily done as the Magnum 200X's steel case is strong.

Should vertical mounting of the unit (such as on a wall surface) be desired, operation and cooling are not impaired but no brackets for vertical mounting are provided by Garrett Communications.

3.3Connecting Ethernet Media

The Magnum 200X Two-Port Repeater is specifically designed to support connections for any two Ethernet segment media types within a single unit. This is accomplished by using a family of Repeater Port Modules (RPMs). The various media types supported along with the corresponding IEEE 802.3 standards and connector types

Image 25
Contents Magnum Two-Port Repeaters Page Trademarks Magnum Two-Port Repeaters Installation and User GuideContacting Garrett Communications Table of Contents Magnum Line Workgroup Bridges, 10Mb series Fan-Outs, 10Mb series Page Network Standards ConnectorsMaximum Ethernet Segment Lengths LED Indicators on Chassis Magnum 200X Power Supply InternalPackaging 200X Specifications Repeater Port Modules RPMs WarrantyOrdering Information Introduction Magnum 200X Spare PartsInspecting the Package and Product Product Description Magnum 200X Repeater Port Modules RPMs 1 MagnumRPM-FST, RPM-FSC, RPM-TP Magnum RPM Cards RPM-BNC, RPM-AUI, RPM-DTERPM-TP Twisted Pair Magnum RPM-BNCMagnum RPM-TP Page Magnum RPM-FST ShellMagnum RPM-FSC RPM-FSC Fiber SC, Snap-in ConnectorRPM-SMF Single-mode Fiber 10 km Jumper Across Distances SupportedNot used RPM-DTESix Models for Mixed Media Segment 10BASE2 BNCPage Locating the Magnum 200X Two-Port Repeater Connecting Ethernet MediaMagnum 200X Table-Top / Shelf Mounting Connecting ThinNet 10BASE2 BNC Connecting Twisted Pair RJ-45, Unshielded or ShieldedConnecting Drop Cable 10BASE5 DTE Connecting ThickNet 10BASE5 AUIConnecting Single-Mode Fiber Optic SMF Connecting Fiber Optic SC-type, Snap-onStop Side view of RPM card Repeater Functionality Magnum 200X chassis unit Chassis LEDsBefore Calling for Assistance Return Material Authorization RMA Procedure Page Power Supply Internal 48 VDC Option B1.0 Specifications for Magnum 210X TWO-PORT RepeatersB2.0 48V DC Power OPTION, Theory of Operation B3.0 ApplicationsB5.0 Operation B4.1 UL RequirementsB6.0 Ordering Information