GarrettCom Magnum 20X B1.0 Specifications for Magnum 210X TWO-PORT Repeaters, B3.0 Applications

Page 36
POWER SWITCH

B1.0 SPECIFICATIONS - FOR MAGNUM 210X TWO-PORT REPEATERS

Power Supply (Internal 48 VDC Option)

DC Power Connector: 3 terminals: -“, “GND”, “+”

Input Voltage: 36 - 70 VDC (auto-ranging)

Power Consumption: Model 210X: 8 watt typical, 15 watts max.

With the exception of the power supply, all specifications and functions of Magnum 210X-48VDC models are identical to Magnum 200X listed in the main manual.

B2.0 48V DC POWER OPTION, THEORY OF OPERATION

The 48VDC power option is designed using diodes inside on each DC power input line behind the two external power connection terminals, so that the power from an

external source can only flow into the

REPEATER

repeater. This allows the repeater to operate

 

 

 

 

 

 

 

 

SUPPLY

 

A+

 

 

 

 

 

+ FUSE

 

only whenever DC power is correctly

A-

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

applied to the two inputs. It protects the

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

CHASSIS

repeater from incorrect DC input

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

connections. An incorrect polarity connection, for example, will neither effect the repeater, nor its power supply internally, nor will it blow the fuse in the internal power supply.

B3.0 APPLICATIONS

Magnum 210X repeaters are easily installed in a variety of applications where 48 VDC power is used as the primary power source. The 48VDC power configuration provides an Ethernet networking solution utilizing a special power supply in hubs with a proven track record.

The solution is particularly useful in the telecommunication industry, where it is common for facilities to operate on 48VDC power. Such companies include regular and

wireless telephone service providers, Internet Service Providers (ISPs) and other

_ G N D

36-75VD

Image 36
Contents Magnum Two-Port Repeaters Page Magnum Two-Port Repeaters Installation and User Guide TrademarksContacting Garrett Communications Table of Contents Magnum Line Workgroup Bridges, 10Mb series Fan-Outs, 10Mb series Page Connectors Network StandardsMaximum Ethernet Segment Lengths Magnum 200X Power Supply Internal LED Indicators on ChassisPackaging 200X Warranty Specifications Repeater Port Modules RPMsOrdering Information Magnum 200X Spare Parts IntroductionInspecting the Package and Product Product Description 1 Magnum Magnum 200X Repeater Port Modules RPMsMagnum RPM Cards RPM-BNC, RPM-AUI, RPM-DTE RPM-FST, RPM-FSC, RPM-TPMagnum RPM-BNC RPM-TP Twisted PairMagnum RPM-TP Page Shell Magnum RPM-FSTRPM-FSC Fiber SC, Snap-in Connector Magnum RPM-FSCRPM-SMF Single-mode Fiber Jumper Across Distances Supported 10 kmNot used RPM-DTESix Models for Mixed Media 10BASE2 BNC SegmentPage Connecting Ethernet Media Locating the Magnum 200X Two-Port RepeaterMagnum 200X Table-Top / Shelf Mounting Connecting Twisted Pair RJ-45, Unshielded or Shielded Connecting ThinNet 10BASE2 BNCConnecting ThickNet 10BASE5 AUI Connecting Drop Cable 10BASE5 DTEConnecting Fiber Optic SC-type, Snap-on Connecting Single-Mode Fiber Optic SMFStop Side view of RPM card Repeater Functionality Chassis LEDs Magnum 200X chassis unitBefore Calling for Assistance Return Material Authorization RMA Procedure Page B1.0 Specifications for Magnum 210X TWO-PORT Repeaters Power Supply Internal 48 VDC OptionB2.0 48V DC Power OPTION, Theory of Operation B3.0 ApplicationsB4.1 UL Requirements B5.0 OperationB6.0 Ordering Information